T1/E1 Copper Line Configuration Settings: 

The T1/E1 copper line codes and line lengths are configured using dip switches located 
on the side of the Flex Point T1/E1 media converter. 
 
 

Line Type

 

Port Type

 

Distances

 

 

Switch Positions 

 

 

 

 

 

 

 

1      2      3      4 

T1 DSX-1 

RJ-45/48 

    0’ – 133’ 

 

D     D     D     D  

T1 DSX-1 

RJ-45/48 

133’ – 266’ 

 

D     D     D     U 

T1 DSX-1 

RJ-45/48 

266’ – 399’ 

 

D     D     U     D 

T1 DSX-1 

RJ-45/48 

399’ – 533’ 

 

D     D     U     U 

T1 DSX-1 

RJ-45/48 

533’ – 655’ 

 

D     U     D     D 

 
T1 DS-1 

RJ-45/48 

  0 dB   

 

D     D     D     D 

T1 DS-1 

RJ-45/48 

-7.5 dB 

 

D     U     D     U 

T1 DS-1 

RJ-45/48 

-15.0 dB 

 

D     U     U     D 

T1 DS-1 

RJ-45/48 

-22.5 dB 

 

D     U     U     U 

 
E1 75 ohm  

Coax/BNC 

Standard 

 

U     D     D     D 

E1 120 ohm   RJ-45/48 

Standard 

 

U     D     D     U 

E1 75 ohm 

Coax/BNC 

Extended 

 

U     D     U     D 

E1 120 ohm  RJ-45/48 

Extended 

 

U     D     U     U 

 
 

 

 

 

 

 

 

D = Down         U = Up 

 
 
 

Operational Switch Settings and Functions: 

The following operational switches located on the front of the Flex Point T1/E1 converter 
are to assist in installation and fault isolation. 
 

NORM

NORM

NORM

NORM

NORMAL

L/LB

R+L/LB

FO/1's

UTP/1's

Local Dual Loop Back

Remote & Local Loop Back

Force 1's to Fiber

Force 1's to Copper

 

 
 

Содержание MT660A-MM

Страница 1: ...TOMER Order toll free in the U S Call 877 877 BBOX SUPPORT outside U S call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing a...

Страница 2: ...with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9VDC 1 Amp 2 This product should always be used only with the supplied power unit 3 Models shipped with international power supplie...

Страница 3: ...ed for the active pins Set the UTP DCE DTE switch for the RJ 45 48 port to the appropriate setting Note Use copper cables that are compliant with the specifications that are outlined in copper cable s...

Страница 4: ...1 DS 1 RJ 45 48 0 dB D D D D T1 DS 1 RJ 45 48 7 5 dB D U D U T1 DS 1 RJ 45 48 15 0 dB D U U D T1 DS 1 RJ 45 48 22 5 dB D U U U E1 75 ohm Coax BNC Standard U D D D E1 120 ohm RJ 45 48 Standard U D D U...

Страница 5: ...eceived on the coax or twisted pair will be disabled and data being received on the fiber is passed through to the coax or twisted pair side By returning the switch to the normal position the unit wil...

Страница 6: ...of operation and return a signal to the sending unit An LED on the local and remote Flex Point T1 E1 converters will show a configuration that the fiber segment is communicating properly between devi...

Страница 7: ...nk All Ones received Test Green Off Normal Operation On L LB or All 1 s Test Mode Blink R L LB Received Master Fast Blink R L LB Received Slave Fiber Cable Specifications Multimode Cable 50 125 62 5 1...

Страница 8: ...ance 6 000 ft Twisted Pair cable for E1 Gauge 22 to 24 AWG Impedance 120 ohm 10 Impedance characteristic 2 6 dB 100m 1 0 MHz Maximum Distance 8 000 ft Coax cable for E1 Gauge 22 to 24 AWG Impedance 75...

Отзывы: