background image

3 of 4

2/26/2007
#11835

724-746-5500

   blackbox.com

TECH SPECS

Budget (Maximum) —

MT612A-ST, MT651A-ST-R2, MT619A-ST-R2, MT651C: 

20 dB over 62.5/125-µm multimode fiber cable;

MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3, MT620AE-R2, 

MT650C-R2: 22 dB over 9/125-µm single-mode fiber cable

Compliance — 

EMI/RFI: CE; FCC Part 15 Subpart B Class A, IC Class/classe A; 
Safety: EN 60950, EN 41003

Data Rate (Maximum) — 

T1: 1.544 Mbps; 
E1: 2.048 Mbps

Diagnostic — 

Dry-contact closure alarm on various DB15 pins

(standalone models) or RackNest DB25 pins (card models) for signal
or power loss; minimum switching current 1 A

Distance (Maximum) — 

MT612A-ST, MT618A-ST-R3: 3.1 mi. (5 km);
MT651A-ST-R2, MT651C: 4.3 mi. (6.9 km); 
MT650A-ST-R3, MT653A-ST-D48-R3, MT620AE-R2, MT650C-R2: 

31 mi. (49.9 km);

MT619A-ST-R2: 1.5 mi. (2.4 km)

Dynamic Range — 

28 dB

Output Power — 

Single-mode: -12 dBm; 
Multimode: -18 dBm

Overvoltage Protection — 

AC/DC overvoltage circuits are connected through transformers to
transmit and receive lines

Receiver Sensitivity — 

For a BER of 10-9:

MT612A-ST, MT651A-ST-R2, MT619A-ST-R2, MT651C: -38 dBm;
MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3, MT620AE-R2,

MT650C-R2: -40 dBm

User Controls — 

MT612A-ST: Internal: (1) 4-position DIP switch, 

(6) 2-position jumpers, (1) 5-position jumper;

All other models: (1) front-mounted slide switch for test mode; 
All others mounted on main board (internal): 

(1) jumper block for interface type; 
(1) jumper and (3) DIP switches for grounding control

and signal loss handling

Video Standards — 

VGA, SVGA, XGA, XGA-2

Zero Suppression — 

B8ZS when set to T1, HDB3 when set to E1

Interface — 

Electronic: Either 100-ohm balanced T1, 120-ohm balanced E1, 

or 75-ohm unbalanced E1, user-selectable; with card models, 
unbalanced E1 requires special adapter—call Technical Support; 

Optical: MT612A-ST: 820-nm multimode;

MT651A-ST-R2, MT619A-ST-R2, MT651C: 850-nm multimode;
MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3, 

MT620AE-R2, MT650C-R2: 1300-nm single-mode

Connectors — 

Standalone models (all rear-mounted): 

For fiber optic link: (2) ST F;
For balanced T1 or E1 I/O and for dry-contact alarm: (1) DB15 F; 
For unbalanced E1 I/O: (2) BNC F; 
For power: 

MT653A-ST-D48-R3: (1) standard 3-pin F; 
All other models: (1) IEC 320 M inlet; 

Card models:

For fiber optic link: 

(2) front-mounted ST F; Rear-mounted card-edge F linked to 
connectors on rear of RackNest 2/14; 

For balanced T1/E1: (1) 5-position terminal block; 
For unbalanced E1: Special plug-in adapter required—

call Technical Support;

For dry-contact alarms: (1) DB25 F

Indicators —

MT612A-ST: (2) LEDs: (1) Power, (1) Link;

All other models: (6) or (7) front-mounted LEDs: Power, local 

loopback, remote loopback, and various error conditions

Temperature Tolerance — 

32 to 122°F (0 to 50°C)

Humidity Tolerance — 

Up to 90% noncondensing

Power —

MT612A-ST, MT651A-ST-R2, MT650A-ST-R3: 100–240 VAC, 50/60 Hz, 

autosensing from AC source through included detachable input 
cord; 

MT653A-ST-D48-R3: -48–60 VDC, autosensing at 130 mA, nominal, 

from -48-VDC source through detachable cord (included); 

MT619A-ST-R2, MT618A-ST-R3: 108–132 VAC/207–253 VAC, 

47–63 Hz, autosensing, from AC source through included 
detachable input cord;

MT620AE-R2: 230 VAC, 50 Hz; 
MT651C, MT650C-R2: From the RackNest 2/14 in which 

they’re installed; 

Consumption for all models: 6 W maximum

Size —

MT651A-ST-R2, MT650A-ST-R3, MT653A-ST-D48-R3:

1.7"H x 9.4"W x 6.7"D (4.4 x 23.9 x 17 cm);

All other standalone models: 1.75"H (1U) x 7.6"W x 9.6"D

(4.4 x 19.3 x 24.4 cm); 

Card models: 6.2"H x 0.9"W x 9"D (15.7 x 2.3 x 22.9 cm)

Weight — 

Standalone models: 2.4 lb. (1.1 kg); 

Card models: 0.8 lb. (0.4 kg)

Отзывы: