background image

877-877-2269   |   blackbox.com 

Page 8

Chapter 1: Specifications

Mass Charging Cabinets for Chromebook

 Computers and Laptops Specifications (continued)

Part #

MSC-120-CCN

MSC-120-CNN

MSC-144-CCN

MSC-144-CNN

Approvals

UL

®

 approved power strips

Assembled

Yes

Cable Access

Built-in knockout panels

Built-in knockout panels

Built-in knockout panels

Built-in knockout panels

Cable Management

Yes

No

Yes

No

Casters

2.5" casters and leg levelers

2.5” casters and leg levelers

2.5” casters and leg levelers

2.5” casters and leg levelers

Color

Black

Black

Black

Black

Components 
Included

• (1) Mass Storage and Charging  
   Cabinet (RM2520A) 
• (10) Medium Shelves (UCCSHELFM-12) 
• (10) Front cable management bars 
• (10) Rear cable management bars 
• (10) 12-outlet power strips  
   (PDUBH12-S15-120V-R3) 
• (2) Automated Power Controllers  
   (CARTTIMER1) 
• (1) 12-ft. (3.6-m) Power Cord (UCCPC)

• (1) Mass Storage and Charging Cabinet  
   (RM2520A) 
• (10) Medium Shelves (UCCSHELFM-12) 
• (10) Rear cable management bars 
• (10) 12-outlet power strips  
   (PDUBH12-S15-120V-R3) 
• (2) Automated Power Controllers  
   (CARTTIMER1) 
• (1) 12-ft. (3.6-m) Power Cord (UCCPC)

• (1) Mass Storage and Charging Cabinet  
(RM2640A) 
• (12) Medium Shelves (UCCSHELFM-12) 
• (12) Front cable management bars 
• (12) Rear cable management bars 
• (12) 12-outlet power strips  
   (PDUBH12-S15-120V-R3) 
• (2) Automated Power Controllers  
   (CARTTIMER1) 
• (1) 12-ft. (3.6-m) Power Cord (UCCPC)

• (1) Mass Storage and Charging Cabinet  
(RM2640A) 
• (12) Medium Shelves (UCCSHELFM-12) 
• (12) Rear cable management bars 
• (12) 12-outlet power strips  
   (PDUBH12-S15-120V-R3) 
• (2) Automated Power Controllers  
   (CARTTIMER1) 
• (1) 12-ft. (3.6-m) Power Cord (UCCPC)

Construction

16-gauge steel cabinet and doors

16-gauge steel cabinet and doors

16-gauge steel cabinet and doors

16-gauge steel cabinet and doors

Device Capacity

(120) Chromebook

 computers/laptops, 

(12) per shelf

(120) Chromebook

 computers/laptops, 

(12) per shelf

(144) Chromebook

 computers/laptops, , 

(12) per shelf

(144) Chromebook

 computers/laptops,  

(12) per shelf

Doors

Mesh front door and  

split rear mesh door

Mesh front door and  

split rear mesh door

Mesh front door and  

locking split rear mesh door

Mesh front door and 

locking split rear mesh door

Locking

Key: Locking front door and rear access 

panel for easy cable management 

(keyed differently)

Key: Locking front door and rear access 

panel for easy cable management  

(keyed differently)

Key: Locking front door and rear access 

panel for easy cable management  

(keyed differently)

Key: Locking front door and rear access 

panel for easy cable management (keyed 

differently)

Power Management 
Dividers

130

130

156

156

Power (Input)

110-120 VAC (6-foot attached power 
cord included), 50/60 Hz, 
Plug type: 5-15P, 
Outlet type: 5-15R

110-120 VAC (6-foot attached power 
cord included), 50/60 Hz, 
Plug type: 5-15P, 
Outlet type: 5-15R

110-120 VAC (6-foot attached power 
cord included), 50/60 Hz, 
Plug type: 5-15P, 
Outlet type: 5-15R

110-120 VAC (6-foot attached power cord 
included), 50/60 Hz, 
Plug type: 5-15P, 
Outlet type: 5-15R

Power Outlet

120, via (10) 12-outlet power strips

120, via (10) 12-outlet power strips

144, via (12) 12-outlet power strips

144, via (12) 12-outlet power strips

On/Off Switch

Yes

Yes

Yes

Yes

Dimensions (Cabinet)

Interior:  
    66.5"H (38U) x 21.3"W x 38.5"D    
    (168.9 x 54.1 x 97.8 cm); 
Exterior:  
    70.7"H (38U) x 23.6"W x 39.4"D       
    (179.6 x 59.9 x 100.1 cm) 

NOTE:  Exterior height does not include 

casters.

Interior:  
    66.5”H (38U) x 21.3”W x 38.5”D    
    (168.9 x 54.1 x 97.8 cm); 
Exterior:  
    70.7”H (38U) x 23.5”W x 39.4”D       
    (179.6 x 59.9 x 100.1 cm) 

NOTE:  Exterior height does not include 

casters.

Interior:  
    73.5”H (42U) x 21.3”W x 41.7”D    
    (186.7 x 54.1 x 105.9 cm); 
Exterior:  
    77.6”H (42U) x 24”W x 43.5”D       
    (197.1 x 61 x 110.5 cm) 

NOTE:  Exterior height does not include 

casters.

Interior:  
    73.5”H (42U) x 21.3”W x 41.7”D    
    (186.7 x 54.1 x 105.9 cm); 
Exterior:  
    77.6”H (42U) x 24”W x 43.5”D       
    (197.1 x 61 x 110.5 cm) 

NOTE:  Exterior height does not include cast-

ers.

Dimensions (Slot)

With cable management:  
      10.5”H x 1.12”W x 15”D  
      (26.67 x 2.84 x 38.1 cm) 
  

NOTE:  This can be changed by using 

the zero U cable managers (if 
available for the shelf) or by  
raising the position of the cable 
management bar.

Without cable management: 
      12.25”H x 1.12”W x 15”D  
      (31.11 x 2.84 x 38.1 cm)

With cable management:  
      10.5”H x 1.12”W x 15”D  
      (26.67 x 2.84 x 38.1 cm) 
  

NOTE:  This can be changed by using the 

zero U cable managers (if avail-
able for the shelf) or by  
raising the position of the cable 
management bar.

Without cable management:  
      12.25"H x 1.12"W x 15"D  
      (31.11 x 2.84 x 38.1 cm)

Shipping Carton 
Dimensions

80"H x 25"W x 40.5"D  

(203.2 x 63.5 x 102.87 cm)

80"H x 25"W x 40.5"D  

(203.2 x 63.5 x 102.8 cm)

88"H x 25"W x 46"D  

(223.5 x 63.5 x 116.8 cm)

88"H x 25"W x 46"D  

(223.5 x 63.5 x 116.8 cm)

Weight Capacity

2250 lb. (1020.6 kg)

2250 lb. (1020.6 kg)

2200 lb. (997.9 kg)

2200 lb. (1020.6 kg)

Warranty

Cabinet: Lifetime; 

Electronics: 3 years

Содержание MSC-120-CCN

Страница 1: ...CN MSC 120 CCN MSC 168 CCN MSC 60 CNN MSC 84 TNN MSC 120 CNN MSC 168 CNN MSC 72 CCN MSC 96 TCN MSC 144 CCN MSC 192 TCN MSC 72 CNN MSC 96 TNN MSC 144 CNN MSC 192 TNN Order toll free in the U S or for F...

Страница 2: ...Box You ll be live with one of our technical experts in less than 60 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Chro...

Страница 3: ...wn expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void th...

Страница 4: ...n el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyend...

Страница 5: ...d electrician Do not use an extension cord in conjunction with the Cabinet Do not use liquids in or around the Cabinet environment Inadequate repair can create significant hazards to users and is not...

Страница 6: ...CNN 13 2 3 2 MSC 72 CCN and MSC 72 CNN 15 2 4 Cabinet Configuration Examples for Tablet Storage and Charging 17 2 4 1 MSC 84 TCN and MSC 84 TNN 17 2 4 2 MSC 96 TCN and MSC 96 TNN 18 3 Configuration a...

Страница 7: ...ed differently Key Locking front door and rear access panel for easy cable management keyed differently Key Locking front door and rear access panel for easy cable management keyed differently Power M...

Страница 8: ...agement keyed differently Key Locking front door and rear access panel for easy cable management keyed differently Key Locking front door and rear access panel for easy cable management keyed differen...

Страница 9: ...r Locking Key Locking front door and rear access panel for easy cable management keyed differently Key Locking front door and rear access panel for easy cable management keyed differently Power Manage...

Страница 10: ...91 105 105 Power Input 110 120 VAC 6 foot attached power cord included 50 60 Hz Plug type 5 15P Outlet type 5 15R 110 120 VAC 6 foot attached power cord included 50 60 Hz Plug type 5 15P Outlet type...

Страница 11: ...rear access panel for easy cable management keyed differently Power Management Dividers 208 208 Power Input 110 120 VAC 6 foot attached power cord included 50 60 Hz Plug type 5 15P Outlet type 5 15R...

Страница 12: ...1 USB Type A male Construction Plastic outer housing Dimensions 1 75 H x 7 75 W x 3 D 4 45 x 19 69 x 7 62 cm Environmental Indoor Finish Light gray white smooth and glossy plastic outer housing Weight...

Страница 13: ...ate multiple tablets at one time order a 15 unit Cambrionix syncing module Other custom options include network management switches and patch cables for updating and managing Chromebook computers and...

Страница 14: ...CN or MSC 60 CNN cabinet doors open Figure 2 3 Front of MSC 60 CCN showing front cable management bars NOTE The MSC 60 CNN does not have the optional front cable management bars installed Otherwise th...

Страница 15: ...Page 15 877 877 2269 blackbox com 2 3 2 MSC 72 CCN and MSC 72 CNN Figure 2 4 Front and back of MSC 72 CCN or MSC 72 CNN cabinet doors removed Chapter 2 Overview...

Страница 16: ...CN or MSC 72 CNN cabinet doors open Figure 2 6 Front of MSC 72 CCN showing front cable management bars NOTE The MSC 72 CNN does not have the optional front cable management bars installed Otherwise th...

Страница 17: ...MSC 84 TNN Figure 2 7 Front and back of MSC 84 TCN or MSC 84 TNN cabinet doors open Figure 2 8 Front of MSC 84 TCN showing front cable management bars NOTE The MSC 84 TNN does not have the optional f...

Страница 18: ...877 877 2269 blackbox com Page 18 Chapter 2 Overview 2 4 2 MSC 96 TCN and MSC 96 TNN Figure 2 9 Front and back of MSC 96 TCN or MSC 96 TNN cabinet doors closed...

Страница 19: ...CN or MSC 96 TNN cabinet doors open Figure 2 11 Front of MSC 96 TCN showing front cable management bars NOTE The MSC 96 TNN does not have the optional front cable management bars installed Otherwise t...

Страница 20: ...section of the cable manager and place the device side of the charging cable into one of the slots See Figure 3 1 Cable manager Route cable to the front of the cart Loosen screws on cable manager and...

Страница 21: ...Page 21 877 877 2269 blackbox com Chapter 3 Configuration and Setup Cable manager Loosen screws on cable manager and pull up Route cable to the front of the cabinet Figure 3 2 Routing the cable...

Страница 22: ...two screws on the cable manager pull up on the top section of the cable manager and place the device side of the charging cable into one of the slots 3 Replace the top section of the cable manager an...

Страница 23: ...ecommend that a qualified electrician test the circuit you will plug the cart into The circuit should be checked for ground integrity and appropriate branch circuit protection The cart s ground prong...

Страница 24: ...de more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particu...

Страница 25: ...Page 25 877 877 2269 blackbox com NOTES...

Страница 26: ...877 877 2269 blackbox com Page 26 NOTES...

Страница 27: ...Page 27 877 877 2269 blackbox com NOTES...

Страница 28: ...24 7 Tech support available in 60 seconds or less Copyright 2016 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any t...

Отзывы: