2-WIRE SHORT-RANGE DSL LINE DRIVER (HDSL) WITH 10BASE-T
6.3.2 R
ESTART
P
ROCEDURE AND
T
IMEOUTS
The restart procedure is in place to allow the units to re-establish a connection
after the framer begins seeing unframed packets. Table 6-2 shows the amount of
time the framer must see consecutive unframed packets before the unit will restart
and try to establish a new line connection. The reason that there are different
restart times will become apparent after reading the rest of the document. The
511/511E timeout shown refers to the amount of time the 511/511E pattern will
be valid. At the end of this time, the pattern will automatically turn itself off and
the normal data path will be re-established. The ER LED will flash, indicating that
the test has timed out. The ER LED will stop flashing once the 511/511E switch is
placed into the normal position.
Table 6-2. Test mode timing.
Item
Elapsed Time (seconds)
Startup
50
Data Mode
4
511/511E Generator Enabled
60 (The generator will stop after 45
seconds.)
Remote End of an RDL
60
511/511E Timeout
45 (The pattern generator will
automatically turn off after 45 seconds.
The ER LED will flash until you turn off
the 511/511E switch.)