HIGH-SPEED 2-WIRE SHORT-RANGE DSL LINE DRIVER RACK CARD
Figure 5-9. Data mode with 511/511E.
5.2.4 U
SING THE
V.52 (BER) T
EST
-P
ATTERN
G
ENERATOR
To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests
(or with Local Line Loopback tests), follow these instructions:
1. Locate the 511/511E toggle switch on the mDSL Rack Card’s front panel and
move it to the left. This activates the V.52 BER test mode and transmits a 511
test pattern into the loop. If any errors are present, the local modem’s red ER
LED will blink sporadically.
2. If the above test indicates that no errors are present, move the V.52 toggle
switch to the right, activating the 511E test with errors present. If the test is
working properly, the local modem’s red ER LED will glow. A successful 511E
test will confirm that the link is in place, and that the mDSL Rack Card’s built-
in 511 generator and detector are working properly.
NOTE
The V.52 BER tests can be used independently of the Remote Digital
Loopback tests. This requires two operators: (one) to initiate and
monitor the tests at the local mDSL Rack Card, and (one) to do the same
at the remote mDSL Rack Card. In this case, the test pattern sent by
each Rack Card will not be looped back, but will be transmitted down
the line to the other mDSL Rack Card.
Framer
Processor
Processor
Framer
Pattern
Gen./Det.
Pattern
Gen./Det.
Loop
Control
Loop
Control
Line
X
X
X
X