CHAPTER 5: Operation
• ER: Blinks ON/OFF after a 511/511E test has timed out. See
Section 5.2.4
for
more information.
Flashes once to indicate that a CRC error has occurred (during normal
operation) or bit errors have occurred (during 511/511E test).
Only at power up, blinks once every 200 ms if the DTE rate is set to an
unsupported setting.
• TM: Glows yellow to indicate that the mDSL Rack Card has been placed in test
mode. The unit can be placed in test mode by the local user or by the remote
user. The TM LED will flash for 400 msec when a valid packet is received from
the SNMP Management Module.
• NS: (No Signal) glows red to indicate that the local mDSL Rack Card is not
connected with the remote mDSL Rack Card. The TM LED will flash for 400
msec when a valid packet is received from the SNMP Management Module.
5.2 Test Modes
The mDSL Rack Card offers two proprietary loopback test modes, plus a built-in
V.52 BER test-pattern generator to evaluate the condition of the modems and the
communication link. These tests can be activated physically from the front panel or
via the interface.
5.2.1 O
VERVIEW
Figure 5-2 shows the major elements used in the loopback and pattern tests
available in the mDSL Rack Card. Each block has several functions. Following
Figure 5-2 are descriptions that show how the elements are used during test modes.
Figure 5-2. Major elements used in the loopback and pattern tests.
Framer
Processor
Processor
Framer
Pattern
Gen./Det.
Pattern
Gen./Det.
Loop
Control
Loop
Control
Line