background image

6

ASYNC FIBEROPTIC MODEM

Table 3-1. Straps and Switch Settings

STRAP/

FUNCTION

POSITION

FACTORY

SWITCH

SETTING

CARR

Carrier  

ON

ON

constantly ON

Controlled by 

CL

RTS

DLY

RTS/CTS Delay

2 msec

2 msec

5 msec

DCE/

Modem is DCE

DCE

DCE

DTE

Modem is DTE

DTE

3. Set the straps and switch using 

Table 3-1

and 

Figure 3-1

as guides. If the device

connected to the Async Fiber Optic Modem 
is a DCE, set the DCE/DTE switch on the 
Async Fiber Optic Modem to DTE. If the
device connected to the Async Fiber Optic
Modem isa DTE, set the DCE/DTE switch 
on the Async Fiber Optic Modem to DCE. 

4. Align the top half of the cover with the bottom

half and press the two halves together to close
the unit.

Содержание MAY 1994

Страница 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1994 Black Box Corporation All rights reserved ...

Страница 2: ...toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Data TX RX Data TX RX ...

Страница 3: ...s operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This...

Страница 4: ...le Diagnostics None Interface RS 232C V 24 Connectors Both models have 2 SMA optical connectors and 1 RS 232C connector as follows ME600A F 1 DB25F female ME600A M 1 DB25M male Pulse Width Distortion Less than 25 Optical Output Levels 30 dBm into 100 140 fiber 36 dBm into 50 125 fiber Receiver Sensitivity 45 dBm Operating Wavelength 820 nm ...

Страница 5: ... are used 100 140 fiber with attenuation of 4 dB km or 50 125 fiber with attenuation of 3 dB km Temperature 32 to 122 F 0 to 50 C Humidity Up to 95 non condensing Power Derived from the RS 232C interface no external power required Size 0 9 H x 2 1 W x 4 0 D 2 4 x 5 3 x 10 2 cm Weight 2 6 oz 0 07 kg ...

Страница 6: ...e modem is derived from the RS 232 interface The RS 232 port is switch selectable for DCE or DTE operation You can set the carrier for continuous operation for switched operation or for control by the RTS signal Models are available with SMA or ST connectors A typical application is shown in Figure 2 1 Async Terminal Fiber Optic Cable Async Computer Async Fiber Drivers Fig 2 1 Typical Application ...

Страница 7: ...ing of the Async Fiber Optic Modem If the factory settings are correct for your application skip to step 5 If the factory settings need to be changed go to step 2 2 Remove the cover of the Async Fiber Optic Modem by pressing in on the four tabs located on each side of the unit and lifting the top half of the cover from the bottom half ...

Страница 8: ...m is DTE DTE 3 Set the straps and switch using Table 3 1 and Figure 3 1 as guides If the device connected to the Async Fiber Optic Modem is a DCE set the DCE DTE switch on the Async Fiber Optic Modem to DTE If the device connected to the Async Fiber Optic Modem isa DTE set the DCE DTE switch on the Async Fiber Optic Modem to DCE 4 Align the top half of the cover with the bottom half and press the ...

Страница 9: ...the plastic dust caps from the SMA connectors of the Async Fiber Optic Modem Connect the fiber cables to the modems as follows Connect TX at the local modem to RX at the remote modem Connect RX at the local modem to TX at the remote modem 7 Repeat steps 1 through 6 for the modem at the other site The Async Fiber Optic Modem is now ready for operation DTE DCE ON CL CARR DLY 15 2 ...

Страница 10: ...NOTES ...

Отзывы: