UTP AND THIN ETHERNET REPEATERS
4.6 Installation Steps
Before attempting to install your Repeaters, you must have the tools and
parts on hand to complete the operation. Please read Section 5.1.
4.6.1 E
QUIPMENT
P
ROTECTION
NOTE
You must be extremely careful to ensure the safety of persons and
equipment whenever using wires that run between buildings. Both
underground cable runs that are near the surface and overhead runs are
at risk of damage from lightning strikes and must be suitably protected.
This protection must be in place or there will be risk of serious injury or
death.
The service entrance at each end of the wires should be protected in
strict accordance with local safety codes. In addition, to further reduce the
risk of injury or damage to equipment due to lightning strikes or
accidental connection to hazardous AC line voltages, secondary circuit
protection should be installed at the service entrance.
Outdoor cabling installed by the phone company is typically installed
with gas-discharge protection devices, carbon blocks, or no protection
devices at all. If cabling has protection, DO NOT BYPASS these devices—
they will help protect both your equipment and all those who work with it.
If the cable run you will be using is not protected, DO NOT continue with
the installation, STOP. Install suitable protection devices before
proceeding and be sure that the manufacturer’s instructions are followed
fully (including connecting the ground strap)!
This protection is commercially available from a number of
telecommunications distributors and from networking catalog companies.
Before purchasing, make sure that the protective devices are specifically for
use with high-speed data-transmission lines, since some are only for use
with telephone systems and will degrade the quality of the Ethernet signals.
Note that many carbon-block-type protection devices add a significant
load to the line and will not work with our devices. These must be
removed and replaced with suitable protection devices. Units designed for
use with punchdown blocks (“66” blocks) are available from
telecommunications wholesalers as well as through your telecom installer.
Devices with RJ-11 or RJ-45 connections, such as part number ST512A, are
available from your dealer.
If you have any questions regarding which protection devices to use, call
Technical Support.