Installation
To install the IE Managed Miniature Media Converter into a network environment,
connect the proper twisted-pair and fiber cables. In a standalone configuration, or if
direct management is desired, an IP Address will need to be assigned to the
IE Managed Miniature Media Converter after installation. Refer to Assigning IP
Information for information on assigning an IP Address.
Troubleshooting
If a fiber connection cannot be established, perform the following to make sure that
the fiber transceivers on the IE Managed Miniature Media Converter are not
over/under driving the fiber receivers:
•
Make sure the fiber wavelength on both connected devices match (i.e. both are
1310 nm multi-mode fiber).
•
Make sure that FiberAlert is enabled on only one unit when connecting an
IE Managed Miniature Media Converter to another media converter with the
FiberAlert feature.
•
Make sure that the twisted-pair port speed on the IE Managed Miniature Media
Converter matches that of the end devices connected to the IE Managed
Miniature Media Converter. Configure the IE Managed Miniature Media
Converter and its link partner to Auto-Negotiation or, if using Force mode, be
sure speed and duplex match.
•
Management (VLAN tagged or Untagged) traffic will not be allowed to pass
through the data port and will only pass through the fiber port.
•
When using the IE Managed Miniature Media Converter as a PD device,
establish power first, check the LEDs to confirm this, and then connect the serial
port in order to configure the device via a console session. If performing the
steps in the reverse order, the unit will appear dead. The same is true when
connecting a DC terminal block.
To restore the unit to factory default settings, use the
cleandb
function from the
serial port management menu.