background image

3 of 15

5/4/2007
#24435

Get full control of your media converter connections in your

enterprise by ordering a High-Density Media Converter System
II Chassis as well as a plug-in SNMP Management Module. 

Choose from a desktop 3-slot chassis, a 1U rackmount

or desktop 6-slot chassis, or a 3U rackmount 20-slot chassis
(the chassis ship with blank plates already installed, and the 
6- and 20-slot models include rackmounting hardware). 

Each chassis has one additional slot for the SNMP

Management Module, which you order separately and install
in the chassis in order to enable both module and chassis
management. You can even install chassis as an unmanaged
chassis and then add SNMP later—a perfect solution for an
unmanaged network that might migrate to a managed one
at a later date. 

Module’s GUI gives you detailed conversion ports info.

The SNMP Management Module not only also includes MIBs

for SNMP, but it comes with a CD-ROM that contains iView
management software. This software enables you to configure
the chassis and the media converter modules plugged into it in
minutes and provides you with a cross-platform application for
managing intelligent networking devices from virtually any 32-
bit Windows

®

system. The module is compatible with Windows

95/98, Windows 2000, and Windows NT

®

4, as well as HTML.

The user-friendly, comprehensive iView program uses a

clear graphical user interface (GUI). This shows an on-screen
representation of the actual device control panels and gives
you detailed information about the conversion ports.

You can also use the module’s included MIBs with any

standard SNMP program, such as HP

®

OpenView

®

. This enables

you to view SNMP’s in-depth technical data in iView’s easy-to-
use interface. You can even display statistics as charts.

Lock in SNMP configuration and specify backup power.

In situations where you need to disable chassis manage-

ment, simply move the SNMP switch to the off position. 
Even though this makes the modules unmanageable, the 
SNMP agent continues to communicate with installed modules.
Turning management back on returns the modules to manage-
ment control and any settings you’ve set in iView.

For peace of mind, an SNMP write-lock switch protects

the configurations of your installed modules from being
accidentally overwritten. Even better, the SNMP slot saves
your SNMP settings even when the SNMP Management
Module is removed from the chassis.

And, for the chassis themselves, we offer redundant power

supplies, which help you isolate mission-critical applications
from points of failure. A “last gasp” feature alerts you when
one of the power supplies or AC power fails. What’s more, the
3-slot chassis can even be configured with both an AC and a DC

power supply, enabling you to fall back on DC power
should your AC power fail. 

And there are even more features to ensure reliability: 

The 20-slot chassis has dual fans that are easily field
replaceable, and the 3-slot and 6-slot chassis boast a fan test
feature and have fans that activate only when the chassis
reaches a preset temperature. Fan speed and chassis
temperature can be monitored remotely via SNMP. 

Connect to your network and configure with ease.

The chassis connects to your LAN via an external 10BASE-T/

100BASE-TX twisted-pair connection on the installed SNMP
Management Module. Simply plug one end of a CAT5 or higher
UTP cable into the module’s MGMT port and plug the other
end into a switch, hub, or other networking device on your
LAN.

Because the twisted-pair port has an auto-cross design, 

it automatically enables either a crossover or a straight-through
connection to match the pinning of your connected device.
No crossover cables are required!

Once you connect a chassis to your network, you can assign

the device its own IP address.

This initial IP address configuration can be done in-band

through the management module’s twisted-pair port while
using the HubControl utility (included on the iView CD) or out-
of-band through the management module’s RS-232 port using
Dynamic Host Configuration Protocol (DHCP). (Because the
chassis has an embedded DHCP agent, its IP address is
dynamically assigned when connected to a LAN with a DHCP
server.) The SNMP Management Module also includes a TFTP
client and supports Telnet

.

Of the two IP address assignment routes, the second is the

simplest. Simply plug the included straight-through-pinned
cable into the module’s DB9 connector and the other end into
the appropriate port on your computer or terminal that’s set
for VT100

emulation. 

The HubControl utility can also be used to initiate remote

SNMP configuration for SNMP-manageable devices. This way,
you can get a head start on adding subnet masks, trap
assignments, and other management functions. You can also
use HubControl to upload new versions of the system software
and new MIB information.

Once the chassis has an IP address assigned, use the iView

software or another SNMP-compatible network management
system, such as HP OpenView, to remotely configure, monitor,
and manage the modules you install in the chassis. Program
subnet masks and default gateways, create community strings
(for both read-only and read/write access), configure traps—all
within a password-protection process!

HIGH-DENSITY MEDIA CONVERTER SYSTEM II CHASSIS WITH MODULAR SNMP

724-746-5500

   blackbox.com

LMC5207A

(with modules installed)

Содержание LMC5101A

Страница 1: ...h Layer 1 or Layer 2 conversion options Fully manageable systems with Layer 1 or Layer 2 conversion options High Density Media Converter System II 2007 All rights reserved Black Box Corporation FREE 2...

Страница 2: ...to power down a chassis in order to change a module The High Density Media Converter System II is easy to integrate into any managed network Not only does it support industry standard SNMP but fiber...

Страница 3: ...lerts you when one of the power supplies or AC power fails What s more the 3 slot chassis can even be configured with both an AC and a DC power supply enabling you to fall back on DC power should your...

Страница 4: ...S 232 with included serial cable Also have an OPTION port for future use Indicators LNK ACT FDX COL TEMP PS FAN A FAN B Temperature Tolerance Operating 32 to 122 F 0 to 50 C Storage 13 to 158 F 25 to...

Страница 5: ...wer supplies all chassis feature redundant 6 8 cfm rated cooling fans to keep them from becoming overheated and causing downtime If you re short on desktop space order Rackmount or Wallmount Brackets...

Страница 6: ...g iView you can set the bandwidth of the module s data ports up to 10 Mbps and forward it in each direction A to B or B to A To edit the data rate for each port in iView choose between 12 predefined r...

Страница 7: ...odules to convert between 100BASE TX and 100BASE FX devices For converters that support autosensing 10 100 Mbps Ethernet see our Layer 2 Media Converter Modules for the High Density Media Converter Sy...

Страница 8: ...smit Receive Individual Modules Single Mode 10 km Order one of each 1310 nm Transmit 1550 nm Receive SC LGC5844C 1550 nm Transmit 1310 nm Receive SC LGC5845C Single Mode Plus 40 km Order one of each 1...

Страница 9: ...ASE T 100BASE TX to 100BASE FX These converters feature an autosensing 10 100 copper port and a 100 Mbps fiber port They re a good choice for remote Fast Ethernet connections to Ethernet devices that...

Страница 10: ...100BASE TX 1000BASE T to 1000BASE SSLX Single Strand Transmit Receive Individual Modules Single Mode 10 km Order one of each 1310 nm Transmit 1550 nm Receive SC LGC5940C 1550 nm Transmit 1310 nm Rece...

Страница 11: ...pinned cabling TECH SPECS Encoding AMI B8ZS HDB3 Fiber Type 50 125 m or 62 5 125 m multimode or 9 125 m single mode Speed Maximum T1 J1 1 544 Mbps E1 2 048 Mbps CE Approval Yes Connectors T1 E1 J1 1...

Страница 12: ...ceive SC LMC5186C 1550 nm Transmit 1310 nm Receive SC LMC5185C DS3 E3 STS 1 Modules for the High Density Media Converter System II provide conversion from BNC coax cable to fiber for DS3 E3 or STS 1 a...

Страница 13: ...ownstream 12 5 Mbps Total 15 Mbps Asynchronous at 2 km 1 2 mi Upstream 2 1 Mbps Downstream 4 25 Mbps Total 6 5 Mbps Connectors 1 RJ 11 1 RJ 45 Power From the High Density Media Converter System II cha...

Страница 14: ...gle mode Modules that support up to 155 Mbps are typically used for Ethernet or Fast Ethernet although because they are transparent to protocol they can also be used in an OC 3 ATM 155 Mbps environmen...

Страница 15: ...nitial setup of the unit as well as modifications in the field you can use the included iView2 SNMP application or a Telnet TFTP or local serial connection In addition to a 100BASE FX fiber port and a...