background image

6

NETWORKING HUB

1. Specifications

Compliance:

FCC Class B, IC Class, VDE Class B, UL

®

listed

Standard:

IEEE 802.3 Ethernet v. 1.0/2.0

LAN Interface:

RJ-45 ports for Category 3 or better twisted-pair cable

Data Rate:

10 Mbps

Partitioning:

Automatic after 32 consecutive collisions

Reconnection:

Occurs after 512 bits of error-free transmission

Maximum Segment Length:

UTP (unshielded 10BASE-T): 100 m (328 ft.)

Indicators:

(17) Front-mounted recessed LEDs: (1) Power, (8) Link/TX, and

(8) RX

Connectors:

(8) Front-mounted shielded-type RJ-45 female

Leads/Signals Supported:

RJ-45 Pins 1, 2, 3, and 6

Enclosure:

High-strength sheet metal

Cooling Method:

Convection

Temperature Tolerance:

Operating:

32 to 122°F (0 to 50°C); 

Storage:

-4 to +140°F 

(-20 to +60°C)

Humidity:

10 to 95% noncondensing

Power:

From wallmount power supply: 

Input:

120 VAC, 60 Hz; 

Output:

12 VDC,

1 amp; 

Power consumption:

6 watts typical, 10 watts maximum

Size:

0.8"H x 5"W x 4.4"D (2 x 12.7 x 11.2 cm)

Weight:

Unit plus power supply: 1.3 lb. (0.6 kg)

Содержание LE2750A

Страница 1: ...e U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site...

Страница 2: ......

Страница 3: ...couraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment...

Страница 4: ...ato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las in...

Страница 5: ...r una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado deb...

Страница 6: ...NETWORKING HUB TRADEMARKS UL is a registered trademark of Underwriters Laboratories Incorporated Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owne...

Страница 7: ...stall Inspect the Complete Package 10 3 2 The Installation Procedure 10 3 2 1 Positioning the Networking Hub on a Table or Shelf 10 3 2 2 Powering Up the Hub 10 3 2 3 Connecting Twisted Pair Segments...

Страница 8: ...T 100 m 328 ft Indicators 17 Front mounted recessed LEDs 1 Power 8 Link TX and 8 RX Connectors 8 Front mounted shielded type RJ 45 female Leads Signals Supported RJ 45 Pins 1 2 3 and 6 Enclosure High...

Страница 9: ...handy piece of 10 Mbps Ethernet test equipment into the network to provide a test port and then remove it after you re finished testing It takes up minimal space and uses minimal power plus it s rugg...

Страница 10: ...and Benefits Interoperability with other Ethernet devices The Networking Hub is interoperable with other Ethernet compliant network devices Each is fully compliant with IEEE 802 3 specifications for...

Страница 11: ...file sharing email printer sharing and other computer information High quality construction A rugged metal enclosure and compliance with rigid Class B emission standards make the hub suitable for comm...

Страница 12: ...orking Hub 3 2 1 POSITIONING THE NETWORKING HUB ON A TABLE OR SHELF The Networking Hub can be placed on a table or shelf and has four rubber feet to provide stability without scratching finished surfa...

Страница 13: ...owered up and functional device attached to it on the other end of the cable 3 3 Cascading You can cascade Networking Hubs in order to expand networks For example use a 10BASE T crossover cable to con...

Страница 14: ...ovide reassurance of normal network activity and help you spot abnormal activity 4 2 Operating Features Partitioning and Reconnection The Networking Hub will automatically partition any port where 32...

Страница 15: ...ged into a functioning electrical outlet Is the Pwr LED on signalling that the unit is receiving proper power 4 If the problem is isolated to a network device other than the Networking Hub replace the...

Страница 16: ...components involved in the problem Any particular application that when used appears to create the problem or make it worse If you cannot solve the problem over the phone return the Networking Hub to...

Страница 17: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2002 Black Box Corporation All rights reserved 2 02...

Отзывы: