24/7 Tech Support Call: 724 746-5500 (Outside U.S.A. Call: 724 746-5500)
Page 5 of 8
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit
Error
Rate:
<10-9
Singlemode fiber (recommended):
9
μ
m
Multimode fiber (recommended):
62.5/125
μ
m
Multimode fiber (optional):
100/140, 85/140, 50/125
μ
m
LE2122A-R4 850
nM
multimode
Fiber Optic Transmitter Power:
min: -20.0 dBm max: -10.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm max: -7.5 dBm
Link
Budget:
12.5
dB
LE2122A-SM-R4
1300
nM
singlemode
Fiber Optic Transmitter Power: min:
-29.0 dBm max: -10.0 dBm
Fiber Optic Receiver Sensitivity: min:
-35.0 dBm max: -14.0 dBm
Link
Budget:
6.0
dB
Copper Cable
Category 3
:
Minimum
Requirement
Gauge
24
to
22
AWG
Attenuation
11.5 dB/100m @ 5-10 MHz
Straight-Through
OR
Crossover Twisted-Pair cable may be used.
Shielded Twisted-Pair (STP)
OR
Unshielded Twisted-Pair (UTP) may be used.
Pins 1&2 and 3&6 are the two active pairs in an Ethernet network.
RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)