Black Box IC483A-R2 Скачать руководство пользователя страница 2

1

FEDERAL COMMUNICATIONS COMMISSION

AND

CANADIAN DEPARTMENT OF COMMUNICATIONS

RADIO FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly,
that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio
communication.  It has been tested and found to comply with the limits for a Class A computing device in
accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when the equipment is operated in a commercial
environment.  Operation of this equipment in a residential area is likely to cause interference, in which case
the user at his own expense will be required to take whatever measures may be necessary to correct the
interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out
in the Radio Interference Regulation of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le
ministère des Communications du Canada.

INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement)

1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4. Todas las instrucciones de operación y uso deben ser seguidas.

5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano

mojado o cerca de una alberca, etc..

6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 

7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de

operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 

9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato

eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en
libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas

u otros aparatos (incluyendo amplificadores) que producen calor.

11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de

operación, o como se indique en el aparato.

12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

Содержание IC483A-R2

Страница 1: ...FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION JUNE 2000 IC483A R2 IC483AE R2 IC483C R2 ...

Страница 2: ...fety Statement 1 Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado 2 Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura 3 Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas 4 Todas las instrucciones de operación y uso deben ser seguidas 5 El apar...

Страница 3: ...tado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación 18 Servicio por personal calificado deberá ser provisto cuando A El cable de poder o el contacto ha sido dañado u B Objectos han caído o líquido ha sido derramado dentro del aparato o C El aparato ha sid...

Страница 4: ...3 CONTENTS 1 Specifications 4 2 Introduction 5 3 Installation 6 3 1 DIP Shunt Settings 6 3 2 LEDs 9 4 Ground Strap and Pin Connections 10 4 1 Ground Strap 10 4 2 Pin Connections 11 ...

Страница 5: ...ock Controls Jumpers for Pin H of V 35 and Pins 12 and 30 Terminal Ready of RS 449 V 35 port DTE DCE jumper selectable RS 422 port DTE DCE jumper selectable Maximum Storage Temperature 158 F 70 C Maximum Operating Temperature 122 F 50 C Power IC481A R2 IC483A R2 115 VAC 60 Hz 16 watt power supply IC483AE R2 230 VAC 50 Hz 16 watt power supply IC481C R2 IC483C R2 Requires 16 watts from RM060 interfa...

Страница 6: ...ipment DCE only The Converter has two jumper selectable configurations One connects RS 422 modem equipment to V 35 terminal equipment DTE to DCE The other connects V 35 modem equipment to RS 422 terminal equipment DCE to DTE Both configurations allow bidirectional data transfer Typical applications appear in Figure 2 1 The Converter s ports should be configured the opposite of the equipment s inte...

Страница 7: ...e See Figure 3 1 for more information on DIP shunt settings Figure 3 1 Quick Setup Guide for DIP Shunt Settings V 35 DTE STEP 1 SEE STEP 4 W1 W2 NOT USED USED A B C A B C STEP 2 A B XW5A XW4A STEP 2 XW3B XW1B 422 DTE STEP 1 SEE STEP 4 W1 W2 NOT USED USED A B C A B C STEP 3 A B XW5B XW4B STEP 3 XW3A XW1A DTE DCE DTE DCE OR DTE DCE 422 V 35 DCE DTE IC483A R2 DCE DTE 422 V 35 DTE DCE IC483A R2 DTE DC...

Страница 8: ...W1 is in the B C position the DTR signal pin H is passed from the V 35 port through to pins 12 and 30 of the RS 422 port If W1 is placed in the A B position pins 12 and 30 are forced high When the V 35 side of the Converter is configured as DTE W1 has no effect and W2 is used instead With W2 in the A B position the terminal ready DTR signal is passed from the RS 422 side of the V 35 port With W2 i...

Страница 9: ...oard Layout Showing LED Indicators and Plug Connectors W2 W1 XW6 DTE DCE J2 J1 RX V 3 5 RS 4 4 9 X W 5 A X W 4 A X W 3 A X W 2 A X W 1 A X W 5 B X W 4 B X W 3 B X W 2 B X W 1 B V 35 DTE RS 422 DTE FG AC AC SG 1 2 3 4 ...

Страница 10: ...he LEDs indicates the uses of the LEDs for an RS 422 DTE V 35 DCE configuration The row of type below the LEDs indicates the uses of the LEDs for a V 35 DTE RS 422 DCE configuration See Figure 3 3 and Figures 4 5 and 4 6 For the card version the LEDs are distinguished on the pull lever Figure 3 3 Front Panel LEDs ...

Страница 11: ...TED DATA TERMINAL TIMING TERMINAL TIMING TRANSMIT TIMING TRANSMIT TIMING A C E H K P S U W Y AA B D F J L R T V X BB REMOTE LOOPBACK RECEIVED DATA RECEIVED DATA RECEIVE TIMING RECEIVE TIMING SIGNAL GROUND CLEAR TO SEND RECEIVE LINE SIGNAL DETECT LOCAL LOOPBACK TEST PATTERN 1 SHIELD 2 3 4 SEND DATA 5 SEND TIMING 6 RECEIVE DATA 7 REQUEST TO SEND 8 RECEIVE TIMING 9 CLEAR TO SEND 10 11 DATA MODE 12 TE...

Страница 12: ...nd the V 35 port configured as DCE the signal directions are reversed2 Pins 12 and 30 of the RS 422 port become outputs See Figure 4 4 for jumper W1 settings Figure 4 3 Signal directions for RS 422 port configured as DCE V 35 port configured as DTE 1NOTE In this configuration W1 has no effect on the circuit W2 is used instead Figure 4 4 Signal directions for V 35 port configured as DCE RS 422 port...

Страница 13: ...4 5 The Converter Configured for RS 422 as DTE and V 35 as DCE 4 22 6 24 7 25 9 27 11 29 13 31 5 23 8 26 17 35 12 30 P S DS5 TD DS6 RD R T C D E DS3 RTS DS1 CTS F Y AA DS9 DTR DM DS4 RR DS8 TC DS7 RC V X U W H C A B W1 CTS RTS RR TD RD RC TC DM DS4 DS3 DS2 DS1 DS5 DS6 DS7 DS8 DS9 POWER DS10 ...

Страница 14: ...and V 35 as DTE 4 22 6 24 7 25 9 27 11 29 13 31 5 23 8 26 P S DS6 TD DS5 RD R T C D E DS1 RTS DS3 CTS F Y AA DS2 DSR DS4 SD DS8 TC DS7 RC V X 12 30 H C A B W2 DS9 DM DTR 17 35 U W C RTS CTS SD RD TD RC TC DTR DS4 DS3 DS2 DS1 DS5 DS6 DS7 DS8 DS9 DSR POWER DS10 ...

Страница 15: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved ...

Отзывы: