Speed:

64,000 bps, max.

Connectors:

RS-232 port: DB25 

female; 

RS-422 port: DB37 female

Indicators:

7 LEDs show status of

RS-232 and RS-422 signals and
indicate power ON. RS-232 port:
DSR, CTS, DATA; RS-422 port:
DSR, CTS, DATA

Controls:

RS-232 port: DTE/DCE DIP

shunts; 

RS-422 port: DTE/DCE DIP shunts;
Slide switch to enable receiver 

termination

Temperature:

Storage: -4 to +158°F

(-20 to +70°C); 

Operating: 32 to 122°F (0 to 50°C)

Power:

115 VAC supply: ±10%, 

100 mA; 

230 VAC supply: ±10%, 50 mA

Size: 

Standalone: 2.3"H x 8"W x 
11.9"D (5.8 x 20.3 x 30.2 cm);

Rackmount: 1.2"H x 7.5"W x 11.4"D

(3 x 19.1 x 29 cm)

Weight:

Standalone: 2 lb. (0.9 kg);

Rackmount: 10 oz. (283.5 g)

The converter is easy to set for DCE or DTE operation. Simply install

the DIP shunts in the correct sockets on the circuit board.

One configuration is for connecting RS-422 DCE to RS-232 DTE. The

other configuration is for connecting RS-232 DCE to RS-422 DTE.

There is also a receiver termination switch on the circuit board. It

has a termination switch to insert 120-ohm resistance between the
receive data input leads. To enable termination, set the switch to the ON
position. To disable termination, set the switch to the OFF position.

Technically Speaking

• RS-232 Cable

• RS-442/449 Cable

• Modem eliminator if you want to connect two DTEs together
through the converter

• Cross-over cable if you want to connect two DCEs together
through the converter

Additional equipment you may need

Specifications

Ordering Information

ITEM

CODE

RS-232

RS-422 Interface Converter

115 VAC .................................................................IC456A-R5
230 VAC...............................................................IC456AE-R3
Card........................................................................IC456C-R5

You may also need cable…

RS-232 Cable ...............................................................ECM25C
RS-442/449 Cable ........................................................EDN37J

Connect your RS-232 equipment to your RS-422/449 equipment via the converter.

Modem or other

DCE device

RS-422 Device

4 (T-)

6 (R-)

24 (R+)

22 (T+)

R+

T-

T+

R-

RS-232

422

Interface Converter

DIP-shunt

settings:

DCE       DTE

Straight cable

Отзывы: