CHAPTER 2: Introduction 

2. Introduction 

This manual is intended to assist IT professionals install the Remote Port 
USB 2.0 4-Port. The instructions in this guide assume a general knowledge 
of computer installation procedures, familiarity with cabling requirements, 
and some understanding of USB devices. 

NOTE 

Notes give additional information that could make installation easier. 

2.1 Product 

Contents 

When you open your product for the first time you should find the following 
items: 

 

• 

Remote Port USB 2.0 4-Port User Guide 

• 

Local Unit 

• 

Remote Unit 

• 

AC power adapter (2) 

• 

USB cable (2 meters long) 

To complete the installation, you will also require the following items that 
are not included with the product: 

 

• 

USB 2.0 compatible computer 

• 

USB device 

• 

Category 5 Unshielded Twisted Pair (UTP) cable with two RJ45 
connectors (if using surface cabling), 
OR, 
Category 5 UTP cabling with two information outlets and two 
Category 5 UTP patch cords with RJ45 connectors (if using 
premise cabling) 

NOTE 

The maximum length of the Category 5 UTP cable, including patch cords, must not exceed 50 meters. The 

combined length of any patch cords using stranded conductors must not exceed 10 meters. 

All references to Category 5 UTP cable in this document represent the minimum requirement. 

Category 5E, Category 6 or better UTP cable may be substituted. 

Use only the AC adapters supplied with the Remote Port USB 2.0 4-Port. Use of substitute adapters may 

cause permanent damage to the system and will void the warranty. 

Содержание IC248A

Страница 1: ...der toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporatio...

Страница 2: ......

Страница 3: ...quipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes...

Страница 4: ...camente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuari...

Страница 5: ...camente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del...

Страница 6: ...REMOTE PORT USB 2 0 4 PORT 4...

Страница 7: ...8 3 Installation 11 3 1 Before You Begin 11 3 2 Installing the Local Unit 11 3 3 Installing the Remote Unit 11 3 4 Connecting the Local Unit to the Remote Unit 12 3 5 Checking the Installation 12 3 6...

Страница 8: ...t 5 V DC 3 A Power available to USB devices at Remote Unit 4 x 500 mA USB cable 2 meters 6 6 ft Local Unit connector upstream 1 x USB Type B Local Unit connector downstream 1 x RJ45 Remote Unit connec...

Страница 9: ...e following items that are not included with the product USB 2 0 compatible computer USB device Category 5 Unshielded Twisted Pair UTP cable with two RJ45 connectors if using surface cabling OR Catego...

Страница 10: ...the Remote Port USB USB devices can be located up to 50 meters from the host computer The product is composed of two individual units the Local Unit and the Remote Unit 2 2 1 The Local Unit The Local...

Страница 11: ...ws you to connect up to four USB devices directly Additional devices may be connected by attaching a conventional USB hub to the Remote Unit The Remote Unit is powered by an external AC adapter Front...

Страница 12: ...E Category 5 UTP cabling is the standard data communications cable installed in most commercial and some residential buildings The cables used for horizontal circuits are of solid conductor constructi...

Страница 13: ...let 3 Connect the power adapter to the Local Unit 4 Plug the Type B connector on the USB cable included into the Host port on the Local Unit 5 Plug the Type A connector on the USB cable into the USB p...

Страница 14: ...port on the Remote Unit 3 4 2 With Premise Cabling 1 Plug one end of a Category 5 patch cord not included into the Link port on the Local Unit 2 Plug the other end of the patch cord into the Category...

Страница 15: ...the Remote Port USB has been installed correctly you should find it listed as a Generic USB Hub 3 6 Connecting a USB Device 1 Install any software required to operate the USB device Refer to the docum...

Страница 16: ...trical power Link LEDs on Local Unit and Remote Unit are off Cause There is no connection between the Local Unit and Remote Unit 1 Ensure that a Category 5 UTP cable with straight through conductors i...

Страница 17: ...e properly the first device may not be compatible with the Remote Port USB Contact technical support for assistance All LEDs on both the Local Unit and Remote Unit are on but the device does not opera...

Страница 18: ...complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the pro...

Страница 19: ......

Страница 20: ...Copyright 2006 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746...

Отзывы: