30
CHAPTER 8: RS-232 CONTROL
1.877.877.2269
BLACKBOX.COM
8.3.7 EDID MANAGEMENT
TABLE 8-7. EDID MANAGEMENT
COMMAND
FUNCTION
FEEDBACK EXAMPLE
EDIDMINIT.
Restore the factory default EDID data for each input
All Input EDID Set
Default!
EDIDUPGRADE[XX].
Upgrade EDID via Serial Port
[XX]=00 to 04
(
xx=01 to 04 is the number of input port (enable EDID user-defined for corresponding
HDMI input). If the xx=00, it means all input ports (enable EDID user-defined for all HDMI
inputs).
NOTE: EDID user-defined can be used once. If you switch to another EDID or exit, it will
not be saved.
[XX]=U.
(
xx=U means user-defined for built-in EDID. It can be saved in machine for use at any time.)
NOTE: It can user-defined. There is only one built-in EDID. After finishing it, machine
still uses the previous built-in EDID.
After it receives commands, the machine will remind EDID file (.bin) to send within 10
seconds.
Input XX/User Define
EDID Upgrade OK By
RS232 Or GUI!
EDID/[XX]/[YY].
Input ports xx use built-in EDID yy
[xx]=00 to 04
(xx=01 to 04 is the number of the input port. If the xx=00, it means all input ports.)
[yy]=01 to 09
(yy=01 to 08 means built-in EDID that cannot be user-defined. If the yy=09, it means
user-defined EDID.)
Input 03 EDID
Upgrade OK By 01
Internal EDID!
EDIDGOUT[XX].
Read and print EDID of HDMI output
[XX]=01 to 04 is the number of the output port.
EDIDOUT04:
……
EDIDM[XX]B[YY].
Input port [yy] follows the EDID from output port [xx].
[xx]=01 to 04
(xx=01 to 04 is the number of the output port.)
[yy]=00 to 04
(yy=01 to 04 is the number of input port. If yy=00, it means all input ports.)
Input 01 EDID
Upgrade OK By 04
EXT EDID!
/+[X]/[YY]:XXX.
Send serial data to local
[X]= 1--2400; 2--4800; 3--9600; 4--19200; 5--38400; 6--57600; 7--115200.
[yy] means the output port that sent serial data. yy=01 means local output.
xxx.
NEED HELP?
LEAVE THE TECH TO US
LIVE 24/7
TECHNICAL
SUPPORT
1.877.877.2269