ACS110A-ACS211A -EXTENDER
24
5. Troubleshooting
Monitor
There is no picture.
Check the power supply connection at the Local and Remote unit. Is the
Power
(Red LED) at the Local and Remote unit illuminated? If not, the internal power-
supply may be damaged or there may be an internal error.
Check that the Interconnection cable is connected at the Local Unit and the Remote
Unit. Is the
Link Status
LED illuminated? If not, there may be a problem with the
Interconnection cable:
To ensure a stable data connectionyou must hear the SC plugs of the fibre
cable snap into the sockets and the Link LEDs must be permanent on.
Are there
Errors through data transmission over fibre Cable? Is the
Data Error
LED
illuminated or blinking?
‚DVI 1’ and/or ‚DVI 2’ LED are off: CPU does not provide a video signal – Check
settings of the graphic card.
USB-Keyboard/USB-Mouse
Your USB-keyboard/USB-mouse does not work
Although we tried to design the devices as transparent as possible, we can’t ensure
that all devices are running. Please check on page 32 the list of the tested devices.
USB-HID Device
Your USB-HID device does not work
Although our interface supports HID devices, we can’t ensure that every connected
device is running. In case of a malfunction please contact our technical support.
Other USB-devices
Your USB- device does not work (ACS1xxA without USB 2.0 only)
You have connected a non-HID device. Only HID devices are supported. All other
devices are ignored.
Содержание ACS110
Страница 4: ......
Страница 40: ...ACS110A ACS211A EXTENDER 38 Power 2 5mm barrel type Pin Signal inner 5V outer GND...
Страница 41: ...NOTES...