3.2 Interconnection Cable Requirements
To connect the Local and Remote units you will need:
•
DVI:
Connect the supplied DVI cable(s) to your CPU(s) (KVM - Switch, etc.). Please
ensure that the connection is tension-free!
•
USB-Keyboard, USB-Mouse, USB 2.0:
Connect the supplied USB cable(s) to your
CPU (USB-A to USB-B). Please ensure that the connection is tension-free!
•
Fibre Cables:
•
Multimode:
Two fibres 50
µ
m or 62.5
µ
m. E.g. I-V(ZN)H 2G50 (In house
patch cable)or I-V(ZN)HH 2G62,5 (In house Breakout cable) or I/AD(ZN)H
4G50 (In house OR Outdoor Breakout cable, stress resistant) or
A/DQ(ZN)B2Y 4G62,5 (Outdoor cable, stress resistant with protection against
animal biting). All notations acc. to VDE specification.
1 fibre:
ACS110A and ACS111A
2 fibre:
ACS120A, ACS112A, ACS201A and ACS211A
3 fibre:
ACS122A and ACS202A
A point to point connection is required. Having one or more patch panels
in the line is possible and allowed. Not allowed is a connection from the
fibre link interface to any other products, especially telecommunications or
network equipment.
•
Power Supply:
Connect the supplied 5V/DC power supplies to the
Plug
terminal on the
rear of both the local and the remote unit.