background image

A/B SWITCH WITH REMOTE INTERFACE 

Page 6 of 22 

and can be entered in upper or lower case.  Note however, that password parameters are case sensitive.  All 
commands must be terminated with a carriage return (ASCII 13 or hex 0x0D) before they will be accepted by the 
A/B Switch.  Several commands can be abbreviated by using just the first character of each command word, for 
example the set/get system commands can be abbreviated using “g s” for “get system” or “s s a” for “set system a”. 
 

5.3.1 Serial RS232 Switching on models without Ethernet modules 

 
Typing the word “help” or typing the question mark character “?” followed by a carriage return will cause 
the A/B Switch to display a list of available commands.  Models of the A/B Switch that include an RS232 
console port but that do not also include an Ethernet module support a basic set of serial commands as 
shown in the example output below. 
 
 

>help 
 
d1000 Rev B 
Commands: 
get system 
set system X (X = A or B) 
help or ? (displays this list) 

 
These commands allow you to switch connection states to either the A or B state by using the “set system 
A” command or the “set system B” command, and you can query the switch port connection status by using 
the “get system” command. 
 
 
 

5.3.2 Serial RS232 Switching on models with Ethernet modules

 

 

A/B Switch models that have an Ethernet module installed support the same serial commands as listed in 
section 5.3.1 above, but also include a number of additional commands.  These additional commands 
provide access to the configuration parameters and auto switching features that are supported via the 
Ethernet module.  Refer to section 7 for a complete list of the enhanced console commands. 

 

5.4 Ethernet Switching 

 

 
A/B Switch models that support Ethernet remote control can be switched using commands sent over an Ethernet 
network.  In order to use the Ethernet Network port on the A/B Switch you must set the IPADDRESS, 
SUBNETMASK and GATEWAY address parameters before connecting to your network. See section 6 for more 
details on how to do this.  After setting up the system and powering up for the first time, you may also need to 
change other parameters for your application.  All configuration parameters are stored in non-volatile memory.  
They are immediately active when a change is made, but they will not become permanent until the SAVE command, 
followed by the RESET command has been executed. 
 
Once the Ethernet remote control port has been configured, the A/B Switch can be switched using SNMP commands 
- see the MIB path summary in the appendix for a list of SNMP variables and their functions. 
 
The A/B Switch also supports remote telnet access, and can be controlled via a telnet session using the same 
commands as supported by the RS232 serial interface.  Refer to section 7 for the complete list of console commands. 
 
As an additional option, A/B Switch models that support Ethernet remote control also include a built in http server 
application that allows all of the console commands listed in section 7 to be accessed via a web browser interface. 
See section 8 for more details about the web browser interface feature. 
 
Note that the NETWORK port on the A/B Switch is 10base-T only.  The STATUS LED will blink whenever the 

Содержание 12 VDC load

Страница 1: ...the U S 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence P...

Страница 2: ...ntrol interface E N controllable models only Serial Control Port Female DB9 serial controllable models only Remote Control Status Port 1 6 Position Pluggable Phoenix Terminal Block Power 1 3 5 mm powe...

Страница 3: ...or is removed Non latching versions will revert to the port C to port A connection state when power is lost and will remain in that state when power is restored until a new switch command is received...

Страница 4: ...connect the external contacts to the 6 position terminal block as described in section 5 2 Connect the provided 12 VDC power supply to an AC source and to the 3 5 mm power supply connector on the A B...

Страница 5: ...operation the external dry contacts and any associated cable connected to the 6 position terminal block should not exceed 100 ohms resistance Once the A B Switch has switched connection states the st...

Страница 6: ...n parameters and auto switching features that are supported via the Ethernet module Refer to section 7 for a complete list of the enhanced console commands 5 4 Ethernet Switching A B Switch models tha...

Страница 7: ...ons In order to be able to perform the auto bypass and auto recovery switching functions the A B Switch issues ICMP echo request PING packets from its Ethernet network interface to a user configurable...

Страница 8: ...to that same subnet and use the arp a command to retrieve this information from the P C s arp cache you may need to PING the IP address first before the entry will appear in the arp cache In most net...

Страница 9: ...te with the unit over an Ethernet network You will need to enter an IP address subnet mask and gateway address information for basic access You will also need to set the read and write SNMP community...

Страница 10: ...ress 00 06 57 00 01 02 Subnet Mask 255 255 255 0 Gateway IP Address 192 168 1 1 PING Reply Enabled SNMP Enable Enabled Read Community Name public Write Community Name private Web Enable Enabled Web Pa...

Страница 11: ...come permanent until a SAVE and RESET operation sequence is performed SET PINGREPLY ON OFF GET PINGREPLY Set or display whether or not the A B Switch will respond to incoming PINGs ICMP echo requests...

Страница 12: ...itional level of security Any change will not become permanent until a SAVE and RESET operation sequence is performed SET TELNETENABLE ON OFF GET TELNETENABLE Set or display the current state of telne...

Страница 13: ...ss of the gateway router on the A B Switch subnet If the monitormac address is set to 00 00 00 00 00 00 the A B Switch will automatically determine the proper MAC address required for the PING packet...

Страница 14: ...ll 8 ADMIN IP addresses are 0 0 0 0 no ADMIN IP addresses are configured the A B Switch will allow access via the Ethernet interface from any IP address subject to the existing password and enable fla...

Страница 15: ...rameters from stored settings Note that you will lose your connection and have to log in again if giving this command from a telnet or web interface session SET DEFAULTS Causes the A B Switch configur...

Страница 16: ...be entered in upper or lower case All commands should be terminated with a carriage return ASCII 13 or hex 0x0D Set get system commands can be abbreviated using just first letters i e g s for get syst...

Страница 17: ...t the following page or similar Web Interface Version 1 0 Copyright c 2008 All rights reserved Command console Enter new command Send Command Logoff Figure 8 2 Initial Command Screen At this point you...

Страница 18: ...dress 192 168 1 199 Monitor MAC Address 00 00 00 00 00 00 Monitor Interval 5 Monitor Fail Count 5 Monitor OK Count 5 Read Community Name public Write Community Name private Authentication Trap Disable...

Страница 19: ...B the switch will connect channel B to C d1000KeyStat 1 3 6 1 4 1 9477 1 7 2 D1000 Key Lock Switch Status This is a read only variable This variable can be used to determine if the Key Lock Switch is...

Страница 20: ...address es of the device s that will be receiving the syslog messages by using the SET MANAGER N X X X X command see section 7 for details regarding these commands Once these configuration changes ha...

Страница 21: ...00 192 168 1 151 Bypass Switch System switch from B to A position auto switch B to A via auto bypass feature Jan 1 00 00 00 192 168 1 151 Bypass Switch Automatic switch from B to A position auto switc...

Страница 22: ...A B SWITCH WITH REMOTE INTERFACE Page 22 of 22 Copyright 2010 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746...

Отзывы: