background image

3

IMPORTANT CABLE INFORMATION:

Substantial power loss and reduced battery operating time results from inverters installed with cables that are
not able to supply full power. Symptoms of low battery power can result from cables that are either excessively
long or an insufficient gauge. Marine installations are also subjected to vibration and stresses that exceed those
of other mobile installations. Therefore, the installer/operator should be especially aware of the requirements to
maintain secure, tight, water-resistant electrical connections and to provide for strain relief for DC cables and
appliance wiring. Cable insulation must be the appropriate type for the environment.
• Read And Understand This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE MAXX SST

TM

COMPACT POWER INVERTER MODEL VEC054D.

WARNING: TO REDUCE THE RISK OF INJURY:

• Follow these instructions and those published by battery manufacturer and the manufacturer of any
equipment you intend to use with this unit. Review cautionary markings on these products and on engine.

INTRODUCTION

Thank you for purchasing the 

VEC054D MAXX SST

TM

Compact Power Inverter.

Please read this Instruction

Manual carefully before use to ensure optimum performance and to avoid damage to this product.
This Power Inverter is configured with the latest Soft Start Technology (SST) and supplies continuous power
and peak watts in the form of 120 volt AC outlets to run most household or electronic appliances. Before
introduction of SST, high start-up currents from large inductive loads could shut down an inverter. SST
improves inverter operation by: 
• Gradual voltage ramp-up during inverter start-up, eliminating failed cold starts under load.
• Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start, eliminating

most shutdowns from momentary overloads. 

• A new technology that cools the power transistors more efficiently, and, combined with Soft Start, dramatically

increases reliability and life of the product.

Added safety features include automatic shutdown and a low battery alarm to prevent damage to your battery.

FEATURES

On the front panel are two LED indicators. The green LED indicates power and proper operation of the inverter;
the red LED indicates inverter shutdown from over-load or over-temperature condition, or abnormal input
voltages. The ON/OFF Switch turns the inverter ON and OFF. The switch can also be used to force reset of
inverter circuits by switching it OFF, then back ON again. All models also feature a port to attach a remote
control (sold separately).
120 volt AC power is supplied through three North American three-prong type outlets. The outlets can
accommodate either two- or three-pin AC plugs.

Controls and Functions

Maxx SST™ Safety Features

Built-in Automatic Safety Features include: 

Front View Diagram

Back View Diagram

HIGH-SPEED
COOLING FANS

NEGATIVE (–)
TERMINAL

POSITIVE (+)
TERMINAL

GREEN POWER LED
INDICATOR

RED FAULT 
LED INDICATOR

ON/OFF
POWER
SWITCH

(4) 120 VOLT
AC OUTLETS

WATTAGE
POWER METER

PORT FOR 
REMOTE CONTROL
(SOLD SEPARATELY)

VEC054D_ManualEN_092107.qxp  9/24/2007  3:40 PM  Page 3

Содержание MAXX SST

Страница 1: ...THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER SAVE THIS MANUAL FOR FUTURE REFERENCE Cat VEC054D September 2007 Copyright 2007 Black Decker Printed in China ...

Страница 2: ...like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in PROPER COOLING is essential when operating the inverter Do not place the unit near the vehicle s heat vent or in direct sunlight ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used Receptacles are available having built...

Страница 3: ...SHOCK Do not connect to AC distribution wiring Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This unit is NOT approved for ignition protected areas NEVER immerse the unit in water or any other liquid or use when wet Do not insert foreign objects into the AC outlet or the USB outlet WARNING TO REDUCE THE RISK OF FIRE Do not operate near flammable...

Страница 4: ...form of 120 volt AC outlets to run most household or electronic appliances Before introduction of SST high start up currents from large inductive loads could shut down an inverter SST improves inverter operation by Gradual voltage ramp up during inverter start up eliminating failed cold starts under load Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to...

Страница 5: ... and the ability to operate reactive loads such as those found in inductive motors In this stage the inverter functions as a high power bipolar switch alternately applying opposite polarity to the AC outlet HOT and NEUTRAL terminals Notes Simplified diagram Cables fuse and battery are not included and must be supplied by user The Power Inverter Output Waveform The AC output waveform of the Power I...

Страница 6: ...rted and resume normal operation Note To restart the inverter turn it off and then on again The on off Switch is located on the unit s Front Panel refer to the Control and Functions section of this Instruction Manual The inverter powers resistive loads the easiest however larger resistive loads such as electric stoves or heaters could draw more wattage than the inverter can deliver on a continuous...

Страница 7: ...he battery or batteries is are fully charged If the connections are good and the battery is charged but the voltage still drops below 11 volts you may need to use a larger battery or battery combination CAUTION Rechargeable Devices Certain rechargeable devices do not operate well from a modified sine wave inverter They only operate properly from a standard household outlet which provides a pure si...

Страница 8: ...ttery size you will need to operate appliances from MAXX SST inverters follow these steps 1 Determine the wattage of each appliance and or tool you will need to simultaneously operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt hours of energy use the to...

Страница 9: ...DC the inverter will automatically shut down If the low voltage alarm sounds when the battery is fully charged refer to the Troubleshooting section of this Instruction Manual CIRCUIT PROTECTION The inverter has electronic circuit protection against overload or short circuit conditions CAUTION If turning the ON OFF Switch OFF then ON again does not reset the inverter DO NOT ATTEMPT TO OPEN THE INVE...

Страница 10: ...16 Call Vector Technical Support toll free at 1 800 544 6986 with any questions Installation Procedures When wiring the inverter to a 12 volt DC power source ensure that polarity is correct Reversed polarity will blow a fuse and may cause permanent damage to the inverter Review diagrams on page 3 if necessary to identify the location of the DC terminals Note The manufacturer s warranty does NOT co...

Страница 11: ...ve cables to the battery do not exceed six feet 5 Using an appropriate AWG cable see the diagram on page 7 reposition the inverter and fuse holder if necessary 6 After you have performed the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions Note This procedure is for using locally purcha...

Страница 12: ...pment does not exceed maximum continuous power The Power Inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner described above Do not connect the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to the negative of th...

Страница 13: ...adio Snow in picture Keep inverter and antenna distant from each interference buzzing sound other Use shielded antenna Connect antenna to amplifier Problem Solution Buzzing sound in audio systems Some inexpensive stereo systems and boom boxes emit a buzzing sound from their speakers when operated from the Power Inverter This occurs because the power supply in the electronic device does not adequat...

Страница 14: ...l advice repair or genuine factory replacement parts contact the Black Decker location nearest you To find your local service location refer to the yellow page directory under Tools Electric or call 1 800 544 6986 or visit www blackanddecker com CAUTION If the cord becomes damaged return the entire unit to manufacturer immediately for service repair FULL TWO YEAR HOME USE WARRANTY Black Decker U S...

Страница 15: ...y _ 82 No load current draw 1 0 amp Over voltage shutdown 15 5 0 5 volts DC Low voltage shutdown 10 0 0 3 volts DC Thermal shutdown auto reset Yes North American standard outlets 3 ANL fuse rating for direct hardwire 500 Proper cable gauge AWG 6 ft 1 0 Proper cable gauge AWG 10 ft 3 0 For lengths greater than 10 feet please call 1 800 544 6986 Imported by Black Decker U S Inc 701 E Joppa Rd Towson...

Отзывы: