background image

CARE AND MAINTENANCE

Storage

1. Ideal storage temperature range is 50-68°F (10-20°C).
2. Store and use the inverter in a cool, dry place with adequate ventilation.
3. Avoid locations that are exposed to heating units, radiators, direct sunlight or excessive humidity or

dampness.

Fuse Replacement

This inverter is equipped with multiple internal fuses. Normally, these fuses will not “blow” unless there is a
serious problem inside the unit. 

Internal fuses are replaceable; however, only trained personnel should

attempt fuse replacement.

Refer to the “Service Information” section of this Instruction Manual.

Preventive Maintenance

Inverters require minimal maintenance. For optimum performance, the manufacturer recomments periodically
performing the following preventive maintenance.

1. Turn OFF the inverter using the front panel ON/OFF Power Switch.
2. Remove the DC power fuse.
3. Check and tighten all electrical connections, including the ground.
4. Using a non-metallic vacuum cleaner hose, vacuum the air slots and fan area.
5. Clean the outside of the unit using a damp (not wet) cloth.
6. Wipe unit surfaces thoroughly with a dry cloth.
7. Re-insert the fuse and resume operation.

Accessories

Recommended accessories for use with your tool are available from your local dealer or authorized service center.
If you need assistance regarding accessories, please call: 1-800-544-6986.

WARNING: 

The use of any accessory not recommended for use with this tool could be hazardous.

Service Information

All Black & Decker Service Centers are staffed with trained personnel to provide customers with efficient and
reliable power tool service. Whether you need technical advice, repair, or genuine factory replacement parts,
contact the Black & Decker location nearest you. To find your local service location, refer to the yellow page
directory under "Tools—Electric" or call: 

1-800-544-6986

or visit 

www.blackanddecker.com

.

CAUTION

If the cord becomes damaged, return the entire unit to manufacturer immediately for service/repair.

FULL TWO-YEAR HOME USE WARRANTY

Black & Decker (U.S.) Inc. warrants this product for two years against any defects in material or workmanship.
The defective product will be replaced or repaired at no charge in either of two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it was purchased
(provided that the store is a participating retailer). Returns should be made within the time period of the retailer’s
policy for exchanges (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with
the retailer for their specific return policy regarding returns that are beyond the time set for exchanges.
The second option is to take or send the product (prepaid) to a Black & Decker owned or authorized Service
Center for repair or replacement at our option. Proof of purchase may be required. Black & Decker owned and
authorized Service Centers are listed under "Tools-Electric" in the yellow pages of the phone directory and on our
website www.blackanddecker.com.
This warranty does not apply to accessories. This warranty gives you specific legal rights and you may have other
rights which vary from state to state or province to province. Should you have any questions, contact the manager
of your nearest Black & Decker Service Center. This product is not intended for commercial use.

FREE WARNING LABEL REPLACEMENT:

If your warning labels become illegible or are missing, call 1-800-544-

6986 for a free replacement.

13

VEC054D_ManualEN_092107.qxp  9/24/2007  3:40 PM  Page 13

Содержание MAXX SST

Страница 1: ...THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER SAVE THIS MANUAL FOR FUTURE REFERENCE Cat VEC054D September 2007 Copyright 2007 Black Decker Printed in China ...

Страница 2: ...like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in PROPER COOLING is essential when operating the inverter Do not place the unit near the vehicle s heat vent or in direct sunlight ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used Receptacles are available having built...

Страница 3: ...SHOCK Do not connect to AC distribution wiring Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This unit is NOT approved for ignition protected areas NEVER immerse the unit in water or any other liquid or use when wet Do not insert foreign objects into the AC outlet or the USB outlet WARNING TO REDUCE THE RISK OF FIRE Do not operate near flammable...

Страница 4: ...form of 120 volt AC outlets to run most household or electronic appliances Before introduction of SST high start up currents from large inductive loads could shut down an inverter SST improves inverter operation by Gradual voltage ramp up during inverter start up eliminating failed cold starts under load Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to...

Страница 5: ... and the ability to operate reactive loads such as those found in inductive motors In this stage the inverter functions as a high power bipolar switch alternately applying opposite polarity to the AC outlet HOT and NEUTRAL terminals Notes Simplified diagram Cables fuse and battery are not included and must be supplied by user The Power Inverter Output Waveform The AC output waveform of the Power I...

Страница 6: ...rted and resume normal operation Note To restart the inverter turn it off and then on again The on off Switch is located on the unit s Front Panel refer to the Control and Functions section of this Instruction Manual The inverter powers resistive loads the easiest however larger resistive loads such as electric stoves or heaters could draw more wattage than the inverter can deliver on a continuous...

Страница 7: ...he battery or batteries is are fully charged If the connections are good and the battery is charged but the voltage still drops below 11 volts you may need to use a larger battery or battery combination CAUTION Rechargeable Devices Certain rechargeable devices do not operate well from a modified sine wave inverter They only operate properly from a standard household outlet which provides a pure si...

Страница 8: ...ttery size you will need to operate appliances from MAXX SST inverters follow these steps 1 Determine the wattage of each appliance and or tool you will need to simultaneously operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt hours of energy use the to...

Страница 9: ...DC the inverter will automatically shut down If the low voltage alarm sounds when the battery is fully charged refer to the Troubleshooting section of this Instruction Manual CIRCUIT PROTECTION The inverter has electronic circuit protection against overload or short circuit conditions CAUTION If turning the ON OFF Switch OFF then ON again does not reset the inverter DO NOT ATTEMPT TO OPEN THE INVE...

Страница 10: ...16 Call Vector Technical Support toll free at 1 800 544 6986 with any questions Installation Procedures When wiring the inverter to a 12 volt DC power source ensure that polarity is correct Reversed polarity will blow a fuse and may cause permanent damage to the inverter Review diagrams on page 3 if necessary to identify the location of the DC terminals Note The manufacturer s warranty does NOT co...

Страница 11: ...ve cables to the battery do not exceed six feet 5 Using an appropriate AWG cable see the diagram on page 7 reposition the inverter and fuse holder if necessary 6 After you have performed the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions Note This procedure is for using locally purcha...

Страница 12: ...pment does not exceed maximum continuous power The Power Inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner described above Do not connect the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to the negative of th...

Страница 13: ...adio Snow in picture Keep inverter and antenna distant from each interference buzzing sound other Use shielded antenna Connect antenna to amplifier Problem Solution Buzzing sound in audio systems Some inexpensive stereo systems and boom boxes emit a buzzing sound from their speakers when operated from the Power Inverter This occurs because the power supply in the electronic device does not adequat...

Страница 14: ...l advice repair or genuine factory replacement parts contact the Black Decker location nearest you To find your local service location refer to the yellow page directory under Tools Electric or call 1 800 544 6986 or visit www blackanddecker com CAUTION If the cord becomes damaged return the entire unit to manufacturer immediately for service repair FULL TWO YEAR HOME USE WARRANTY Black Decker U S...

Страница 15: ...y _ 82 No load current draw 1 0 amp Over voltage shutdown 15 5 0 5 volts DC Low voltage shutdown 10 0 0 3 volts DC Thermal shutdown auto reset Yes North American standard outlets 3 ANL fuse rating for direct hardwire 500 Proper cable gauge AWG 6 ft 1 0 Proper cable gauge AWG 10 ft 3 0 For lengths greater than 10 feet please call 1 800 544 6986 Imported by Black Decker U S Inc 701 E Joppa Rd Towson...

Отзывы: