Important Safety InStructIonS for LI-Ion BatterIeS
-SaVe tHeSe InStructIonS-
The battery pack is not fully charged out of the carton. Before using the battery pack and charger, read the safety instructions below. Then follow charging procedures.
Read all InstRuctIons
WaRnInG:
To reduce the risk of injury, basic safety precautions should always be followed including:
•
do not incinerate the battery pack even if it is severely damaged or is completely worn out. The battery pack can explode in a
fire. Toxic fumes and materials are created when battery packs are burned.
•
do not charge or use battery in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Inserting
or removing the battery from the charger may ignite the dust or fumes.
•
If battery contents come into contact with the skin, immediately wash area with mild soap and water. If battery liquid gets into
the eye, rinse water over the open eye for 15 minutes or until irritation ceases. If medical attention is needed, the battery electrolyte for
LI-ION batteries is composed of a mixture of liquid organic carbonates and lithium salts.
•
contents of opened battery cells may cause respiratory irritation. Provide fresh air. If symptoms persists, seek medical attention.
WaRnInG:
Burn hazard. Battery liquid may be flammable if exposed to spark or flame.
• Charge the battery packs only in
BlacK+decKeR LI-ION compatible chargers.
•
do not splash or immerse in water or other liquids. This may cause premature cell failure.
•
do not store or use the tool and battery pack in locations where the temperature may reach or exceed 105°F (40c˚) (such as
outside sheds or metal buildings in summer).
WaRnInG:
Never attempt to open the battery pack for any reason. If battery pack case is cracked or damaged, do not insert into charger. Do
not crush, drop or damage battery pack. Do not use a battery pack or charger that has received a sharp blow, been dropped, run over or damaged in
any way (i.e., pierced with a nail, hit with a hammer, stepped on). Damaged battery packs should be returned to service center for recycling.
WaRnInG:
Fire hazard. do not store or carry battery so that metal objects can contact exposed battery terminals. For
example, do not place battery in aprons, pockets, tool boxes, product kit boxes, drawers, etc., with loose nails, screws, keys, etc.
transporting batteries can possibly cause fires if the battery terminals inadvertently come in contact with conductive materials
such as keys, coins, hand tools and the like. The US Department of Transportation Hazardous Material Regulations (HMR) actually
prohibit transporting batteries in commerce or on airplanes (i.e., packed in suitcases and carry-on luggage) UNLESS they are properly
protected from short circuits. So when transporting individual batteries, make sure that the battery terminals are protected and well
insulated from materials that could contact them and cause a short circuit.
NOTE: Batteries should not be put in checked baggage.
ImpoRtant chaRGInG note
Read manuals originally supplied with charger and tool before charging and using this battery. The batteries should be recharged when they
fail or produce insufficient power on jobs which were easily done previously.
Recharge discharged batteries as soon as possible after
use or battery life may be greatly diminished. For longest battery life, do not discharge batteries fully.
state oF chaRGe IndIcatoR (FIGuRe a)
The battery is equipped with a state of charge indicator. This can be used to display the current level of charge in
the battery during use and during charging. It does not indicate tool functionality and is subject to variation based
on product components, temperature and end-user application.
checKInG state oF chaRGe duRInG use:
• Press the state of charge indicator button (
a1).
• The four LEDs (
a2) will illuminate per the chart in figure a to indicate the percent of charge in the battery.
the RBRc™ seal
The RBRC™ (Rechargeable Battery Recycling Corporation) Seal on the LI-ION battery (or battery pack) indicates
that the costs to recycle the battery (or battery pack) at the end of its useful life have already been paid by
BlacK+decKeR.
RBRC™ in cooperation with
BlacK+decKeR and other battery users, has established programs in the United
States to facilitate the collection of spent LI-ION batteries. Help protect our environment and conserve natural
resources by returning the spent LI-ION battery to an authorized
BlacK+decKeR service center or to your local retailer for recycling. You
may also contact your local recycling center for information on where to drop off the spent battery.
RBRC™ is a registered trademark of the
Rechargeable Battery Recycling Corporation.
service Information
All BLACK+DECKER Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool
service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the BLACK+DECKER location nearest
you. To find your local service location, call:
1-800-544-6986 or visit www.blackanddecker.com.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment. This Class B digital apparatus complies with Canadian ICES-003.
Service Information
All BLACK+DECKER Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool
service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the BLACK+DECKER location nearest
you. To find your local service location, call:
1-800-544-6986 or visit www.blackanddecker.com
InstRuctIon manual
36V / 40V maX* Battery
catalog numbers lBX36, lBXR36, lBXR2036, lBXR2540
a
a2
a1
*Maximum initial battery pack voltage (measured without a
workload) is 40 volts. The nominal voltage is 36.