Cleaning and maintenance

WARNING: Before cleaning and maintenance, 

switch the appliance off and remove the plug from 

the socket, to prevent electric shock.
Note! Always unplug the unit from the mains before 

cleaning. 
Note! Clean the unit regularly to ensure optimal 

performance.

Cleaning the Housing

♦ 

To clean the unit’s housing, wipe it down with a 

soft, damp cloth.

♦ 

Never use aggressive chemicals, gasoline, 

detergents, chemically treated cloths or other 

cleaning solutions to clean the unit, as this may 

cause damage to its components.

Cleaning the Filter

♦ 

To clean the filter, tap it lightly or use a vacuum 

cleaner to remove loose dust and dirt from its 

surface.

♦ 

Once it is dust and dirt-free, rinse the filter 

thoroughly under running water, at a temperature 

of no more than 40 degrees centigrade.

♦ 

Dry the filter thoroughly before placing it back into 

the unit.

Note! NEVER attempt to operate the unit without the 

filters.

Before storing the unit:

♦ 

Drain any water inside the tank.

♦ 

Operate the unit in ventilation only mode for a few 

hours to thoroughly dry the interior.

♦ 

Clean or change the filter.

♦ 

Unplug and store the power cord.

♦ 

Place the unit back into its original box.

♦ 

You can now safely store the unit.

Mains plug replacement

WARNING: The following section on mains plug 

replacement is for authorised service centre persons 

only.
If a new mains plug needs to be fitted:

♦ 

Safely dispose of the old plug.

♦ 

Connect the brown lead to the live terminal in the 

new plug.

♦ 

Connect the blue lead to the neutral terminal.

♦ 

If the product is class I (earthed), connect the 

green/yellow lead to the earth terminal.

Note! If your product is class II double insulated 

(only 2 wires in the cord set), no connection is to be 

made to the earth terminal.
Follow the fitting instructions supplied with good 

quality plugs. Any replacement fuse must be of the 

same rating as the original fuse supplied with the 

product.

Protecting the environment

Separate collection. Products and 

batteries marked with this symbol must 

not be disposed of with normal household 

waste.

Products and batteries contain materials that can 

be recovered or recycled, reducing demand for 

raw materials. Please recycle electrical products 

and batteries according to local provisions. Further 

information is available at www.2helpU.com.

Technical data

BXAC40008GB

Input voltage 

V AC

220-240V

Frequency

Hz

50

Power input

W

1350

Weight

KG

28.5

Содержание BXAC40008GB

Страница 1: ...BXAC40008GB www blackanddecker co uk ...

Страница 2: ...trol Features 1 Remote Control 2 Control Panel 3 Air Outlet 4 Air Inlet 5 Cord Storage 6 Air Inlet 7 Water Stopper Drainage Point 8 Air Inlet 9 Window Hose Air Outlet 10 Air Inlet 11 Hose Adaptor 12 Window Hose 13 Window Adaptor 14 Drain Tube 15 Active Carbon Filter 16 Remote Control 1 2 3 11 12 13 5 4 6 7 8 9 10 14 15 16 ...

Страница 3: ...6 Sleeping Mode Indicator 7 Mode Function Option Soft Touch Button 8 Temperature Up Soft Touch Button 9 Temperature Down Soft Touch Button 10 Indicator For Compressor Operation 11 Full Tank Indicator 12 Low Ventilation Indicator 13 Medium Ventilation Indicator 14 High Ventilation Indicator 15 Receiver For Remote Control 16 Display Window 17 Automatic Mode Indicator 18 Dehumidify Dry Mode Indicator...

Страница 4: ...o reduce the risk of fire electric shock personal injury and material damage Using Your Appliance Please read the operating instructions carefully before using your air conditioner for the first time Check that the voltage of the main circuit corresponds with the rating of the appliance before operating Children shall not play with the appliance Do not let the cable hang over the edge of a table o...

Страница 5: ...appliance is used near pets Do not allow the cord to become twisted After Use While cleaning DO NOT use a wet cloth or use water on any part of the unit as this may cause a short circuit or electrical shock Keep this unit clean Do not allow objects to enter the ventilation opening as this may cause electric shock or damage to the unit Switch off the unit and then remove the plug from the socket wh...

Страница 6: ...erate the unit only at the voltage specified Do not use the unit near open windows as contact with rain and other natural elements could cause an electrical hazard Do not put heavy objects on the appliance Do not tip the unit on its side Never insert any other object into the unit body to avoid any hazard or unit failure Do not put the unit close to heat generating devices or near flammable and da...

Страница 7: ...om with a floor area of less than 10m2 Be aware that the refrigerant may be odourless and that leaks may not be detectable by smell ALWAYS take care to comply with national gas regulations Keep ventilation openings clear of obstruction Store the appliance in a well ventilated area where the room size corresponds to the room area specified for operation Any person who is involved with working on or...

Страница 8: ...Remote Control 2 Control Panel 3 Air Outlet 4 Air Inlet 5 Cord Storage 6 Air Inlet 7 Water Stopper Drainage Point 8 Air Inlet 9 Window Hose Air Outlet 10 Air Inlet 11 Hose Adaptor 12 Window Hose 13 Window Adaptor 14 Drain Tube 15 Active Carbon Filter 16 Remote Control Use About the Controls 3 speed selection 24 hour timer 3 cooling modes and dehumidifying mode Sleep mode LED display Remote Control...

Страница 9: ...o place The remote control is now ready for normal use Assembling Your 3 in 1 Air Conditioner WARNING Before performing any assembly or maintenance switch the unit off and remove it from the power supply Installing the Window Hose Before using your air conditioning unit you will need to install the window hose so that hot air from the appliance is released onto an outside open air area The section...

Страница 10: ...ront of the unit To position the outer louvers gently hold them by the lip and push them upwards or downwards as required Push the louvers upwards to open them or downwards to close them To position the inner louvers gently hold them by the lip and push them sideways to the left or right as required The air flow will be re directed accordingly Temperature Selection While the unit automatically adj...

Страница 11: ...constant temperature until turned off In cooling mode the temperature will increase in fan mode it will decrease Press the Sleep button again while the unit is in sleep mode to turn this function off The fan will resume operation and default to the latest pre set mode and speed settings Note In sleep mode the unit will automatically turn itself off after 12 hours of continuous operation The Timer ...

Страница 12: ...has been drained Note To stop the buzzing indicator sound press any button on the unit s remote control Note Always wait at least 3 minutes after switching off the unit before turning it back on This will help prolong the life of the compressor Draining Without the Tank You can also drain the unit without needing to empty the water tank To do so simply remove the drain plug and plug cap insert the...

Страница 13: ...change the filter Unplug and store the power cord Place the unit back into its original box You can now safely store the unit Mains plug replacement WARNING The following section on mains plug replacement is for authorised service centre persons only If a new mains plug needs to be fitted Safely dispose of the old plug Connect the brown lead to the live terminal in the new plug Connect the blue le...

Страница 14: ...t must be returned to the retailer with proof of purchase or a receipt within the 1st year of purchase For any product related issues after 12 months please contact our customer services team The product must be installed and used in accordance with the instructions contained in this instruction guide It must be used only for domestic purposes It does not cover wear and tear damage misuse or consu...

Страница 15: ... 3KW Power Ampere Consumption 1350W 6 0A Air Volume 410 Compressor Rotary Refrigerant R290 200g Fan Speed 3 Timer 1 24 hours Working Temperature 18o C 32o C Window Hose 150 x 1500mm Net Weight 28 5kg Product Size W x D x H 394 x 352 x 846mm Contact Details Imported by Black Decker 210 Bath Road Slough Berkshire SL1 3YD ...

Страница 16: ...United Kingdom Black Decker Tel 01753 511234 Republic Of Ireland 210 Bath Road Fax 01753 512365 www blackanddecker co uk Slough Berkshire SL1 3YD emeaservice sbdinc com 10 2019 ...