background image

9

X

Keep the battery charger cords loosely coiled during 
storage to prevent damage to the cords.

Troubleshooting

Display indications, common problems and possible 
solutions:

No Functions

X

Make sure that the battery charger is plugged into a live 
230 Vac outlet.

X

Follow the steps outlined in the "Connecting the battery 
charger" at the front of this manual.

F01 - Internal shorted cell battery

If the battery being charged has an internal shorted cell, 

F01

 

will be displayed. We recommend taking your battery to a 
certified automotive service centre for evaluation.

F02 - Bad battery connection or battery voltage too low 

to accept a charge

When 

F02

 is displayed, the most common cause is a poor 

connection to the battery.

X

Follow the steps outlined in "Safety instructions" at the 
front of this manual to disconnect the ac power cord and 
the battery clamps (5), clean the battery terminals and 
reconnect the battery charger.

X

If the situation persists, we recommend taking your battery 
to a certified automotive service centre for evaluation.

F03 - Sulphated or unchargeable battery

F03

 is displayed when the battery is highly sulphated and 

cannot accept a normal charge current.

X

Follow the steps in the Equalizing section to equalize the 
battery.

X

If the situation persists after equalizing, we recommend 
taking your battery to a certified automotive service centre 
for evaluation.

F04 - Overtime condition

F04

 is displayed when the charging time exceeds 18 hours. 

You may be using a charging rate that is too low for the size 
of the battery. Select a higher charging rate to charge the 
battery.

F05 - Overheated condition

F05

 is displayed to indicate that the battery charger is 

overheating. The ventilation grill of the battery charger may 
be blocked.

X

Follow the steps outlined in “Safety instructions” at the 
front of this manual to disconnect the ac power cord and 
the battery clamps (5), allow the appliance to cool for 30 
minutes and reconnect.

X

Make sure that there is ample ventilation before resuming 
operation.

F06 - Reverse polarity

F06

 is displayed if the connections to the battery's positive 

and negative terminals are incorrect.

Follow the steps outlined in “Safety instructions” at the front 
of this manual to disconnect the ac power cord and the 
battery clamps (5) and then reconnect to the battery with the 
correct polarity.

F07 - Alternator voltage

The alternator output voltage is out of the typical operation 
range.

Charging a very cold battery

If the battery to be charged is very cold i.e., in temperatures 
below freezing (0°C/ 32°F), it cannot accept a high rate of 
charge. The initial charge rate will be low. The charge rate 
will increase as the battery warms. Never attempt to charge 
a frozen battery.

Mains plug replacement (U.K. & Ireland only)

If a new mains plug needs to be fitted: 

X

Safely dispose of the old plug. 

X

Connect the brown lead to the live terminal in the new plug. 

X

Connect the blue lead to the neutral terminal. 

Warning! 

No connection is to be made to the earth terminal. 

Follow the fitting instructions supplied with good quality plugs. 
Recommended fuse: 5 A.

Protecting the environment

Should you find one day that your appliance needs 
replacement, or if it is of no further use to you, 
think of the protection of the environment. Black & 
Decker repair agents will accept old Black & 
Decker tools and ensure that they are disposed of 
in an environmentally safe way.

Separate collection of used products and 
packaging allows materials to be recycled and 
used again. Re-use of recycled materials helps 
prevent environmental pollution and reduces the 
demand for raw materials. 

Local regulations may provide for separate collection of 
electrical products from the household, at municipal waste 
sites or by the retailer when you purchase a new product.

Black & Decker provides a facility for the collection and 
recycling of Black & Decker products once they have reached 
the end of their working life. To take advantage of this 
service please return your product to any authorised repair 
agent who will collect them on our behalf.

Содержание BDV1085

Страница 1: ...UK Ireland Australia New Zealand ...

Страница 2: ...2 ...

Страница 3: ...ecified in this manual Power cord safety Warning Neveraltertheacpowercordorplug Ifitwillnotfit haveaproperoutletinstalledbyaqualifiedelectrician Improper connection may result in an electric shock Specific safety instructions for battery chargers This product must be earthed Always check that the power supply corresponds to the voltage on the rating plate Power plugs must match the outlet Never mo...

Страница 4: ...ychargerasfarawayfromthebatteryas theleadswillallow Thebatterychargercontainsswitches that may create a spark X Donot placethe batterycharger above or stand thebattery charger on top of the battery X Explosive gases may collect near the ground Locate the battery charger as high as possible above ground level X Do not use power tools in the charging area X Do not smoke or have naked flames in the c...

Страница 5: ...ating covers to the battery posts Charging a battery disconnected from the circuit Warning Incorrectconnection batteryshortcircuit locationof battery and location of the battery charger may create a hazard Make sure that adequate preparation has been made before proceeding If the battery is not already removed from the circuit follow the manufacturers instructions to remove the battery before char...

Страница 6: ...red Battery voltage pushbutton 14 This pushbutton enables a check to measure the battery voltage Equalize pushbutton 9 This is a recessed pushbutton used to start the equalize process Control panel LEDs fig A WET LED 10 lights when the battery type selector is on wet battery type Maintenance free LED 11 lights when the battery type selector is on maintenance free battery type Float charge LED 6 li...

Страница 7: ...y when equalizing The frequency which the equalization process needs to be run depends on the use of the battery The more the battery is used the more undercharged it becomes thus the more frequently the battery should be equalized Do not use this mode on sealed or valve regulated batteries This mode is only meant for wet unsealed vented batteries X Make sure that there are no flammable sources ne...

Страница 8: ...rnatorand or ground Note The battery voltage pushbutton 14 is disabled in the alternator check mode Note F07 may display because a number of extra accessory loads have been added to the charging system thereby increasing current demand from the alternator Make sure that the alternator is rated to support the application Note This check may not be accurate for every make manufacturer and model of v...

Страница 9: ... 30 minutes and reconnect X Make sure that there is ample ventilation before resuming operation F06 Reverse polarity F06 is displayed if the connections to the battery s positive and negative terminals are incorrect Follow the steps outlined in Safety instructions at the front of this manual to disconnect the ac power cord and the battery clamps 5 and then reconnect to the battery with the correct...

Страница 10: ... This guarantee statement is in addition to and in no way prejudices your statutory rights The guarantee is valid within the territories of the Member States of the European Union and the European Free Trade Area If a Black Decker product becomes defective due to faulty materials workmanship or lack of conformity within 24 months from the date of purchase Black Decker guarantees to replace defecti...

Страница 11: ...11 ...

Страница 12: ...N HFNHU XVWUDOLD 3W WG 7HO OHWFKHU 5RDG 0RRURROEDUN D 9LFWRULD 1HZ HDODQG ODFN HFNHU 7HO XJR RKQVWRQ ULYH D 3HQURVH XFNODQG 1HZ HDODQG 8QLWHG LQJGRP ODFN HFNHU 7HO DWK 5RDG D 6ORXJK HUNVKLUH 6 HOSOLQH 90507193 12 06 ...

Отзывы: