4
ENGLISH
Refit the cover and let it click into place.
Use
Switching on and off
To switch the tool on, turn the sensitivity dial (3) clockwise.
To switch the tool off, turn the sensitivity dial
counterclockwise.
Detecting live wires (fig. C)
Warning!
Test the unit on a known source of AC current
before use.
Make sure unit is away from area being scanned and any
other AC current source.
Set the mode selector switch (1) to the electricity symbol.
Turn the sensitivity dial clockwise until the buzzer sounds
and the red LED indicator is on.
Slowly turn the dial counterclockwise until the buzzer
stops sounding and the red LED indicator is off.
Test the unit by holding it adjacent to a plug connected to
a live socket. Confirm the operation of the red LED
indicator and the buzzer.
The unit is now ready for use and is set to maximum sensitivity.
While holding the unit with one hand place your other
hand on the surface close to the area being scanned.
Move the detector slowly and smoothly across the surface
area, approaching from different directions.
When an AC source is located, the red LED indicator will blink
and the buzzer will sound intermittently.
After detecting the work area repeat the testing procedure
to confirm the operation of the unit.
Detecting metal pipes (fig. C)
Warning!
Test the unit on a known metal object before use.
Make sure unit is away from area being scanned or any
other metal objects when preparing for use.
Set the mode selector switch (1) to the metal symbol.
Turn the sensitivity dial clockwise until the buzzer sounds
and the green LED indicator is on.
Slowly turn the dial counterclockwise until the buzzer
stops sounding and the green LED indicator is off.
Test the unit by holding it adjacent to an exposed metal
object. Confirm the operation of the green LED indicator
and the buzzer.
The unit is now ready for use and is set to maximum sensitivity.
While holding the unit with one hand place your other
hand on the surface close to the area being scanned.
Move the tool slowly across the wall, approaching from
different directions.
When a metal object is detected, the buzzer will sound and
the green LED indicator will come on.
After detecting the work area repeat the testing procedure
to confirm the operation of the unit.
Hints for optimum use
After detecting a hidden object, the sensitivity of the unit
can be gradually reduced to maximise the accuracy.
Slightly turn the sensitivity dial counterclockwise and
continue to move the tool across the detected area from
different directions until the location of the hidden object is
more accurately defined.
Protecting the environment
Separate collection. This product must not be
disposed of with normal household waste.
Should you find one day that your Black & Decker product
needs replacement, or if it is of no further use to you, do not
dispose of it with household waste. Make this product
available for separate collection.
Separate collection of used products and packaging
allows materials to be recycled and used again.
Re-use of recycled materials helps prevent
environmental pollution and reduces the demand for
raw materials.
Local regulations may provide for separate collection of
electrical products from the household, at municipal waste
sites or by the retailer when you purchase a new product.
Black & Decker provides a facility for the collection and
recycling of Black & Decker products once they have reached
the end of their working life. To take advantage of this service
please return your product to any authorised repair agent who
will collect them on our behalf.
You can check the location of your nearest authorised repair
agent by contacting your local Black & Decker office at the
address indicated in this manual. Alternatively, a list of
authorised Black & Decker repair agents and full details of our
after-sales service and contacts are available on the Internet
at:
www.2helpU.com
Battery
At the end of their useful life, discard batteries with
due care for our environment.
Remove the battery as described above.
Содержание BDS200
Страница 2: ...2 A B 4 4 C ...
Страница 41: ...41 ...