background image

Installing the Battery

Ensure laser on/off switch (A) is in the full off position by moving laser button to "O" position.

Remove the battery compartment cover (H). Insert  2 fresh 1.5 volt AA alkaline batteries

making sure to match (+) and (-) terminals correctly. Replace battery compartment cover. 

WARNING: Batteries can explode, or leak, and can cause injury or fire.

To reduce this

risk:

 Carefully follow all instructions and warnings on the battery label and package. 

 Always

insert batteries correctly with regard to polarity (+ and -), marked on the battery and the

equipment.

 Do not short battery terminals.

 Do not charge batteries.

 Do not mix old

and new batteries. Replace all of them at the same time with new batteries of the same

brand and type.

 Remove dead batteries immediately and dispose of per local codes.

Do not dispose of batteries in fire.

 Keep batteries out of reach of children.

 Remove 

batteries if the device will not be used for several months.

“Transporting batteries can possibly cause fires if the battery terminals inadvertently come

in contact with conductive materials such as keys, coins, hand tools and the like.  The US

Department of Transportation Hazardous Material Regulations (HMR) actually prohibit

transporting batteries in commerce or on airplanes (i.e. packed in suitcases and carryon

luggage) UNLESS they are properly protected from short circuits.  So when transporting

individual batteries, make sure that the battery terminals are protected and well insulated

from materials that could contact them and cause a short circuit.”

LOW BATTERY INDICATOR

A battery energy level indicator is displayed in the lower left hand corner of

the display screen. 

Operating Instructions

NOTE: Detecting elements for wood and metal studs and AC Wires are

located in the lower part of the unit.

STUD DETECTION 

For stud detection through up to 3/4 inch (19mm) thick drywall.

1). Hold unit straight up and down and place flat against wall as shown in 

Figure 1

2). Press in and hold the detector on/off button (B). LCD screen (D) will light and detector will

run initialization process. 

3). READY message will appear on LCD screen and the unit will beep once to indicate it is

calibrated and ready for detection.

4). Slide unit slowly,

Figure 2

, horizontally across surface of wall without lifting or tilting. When

the STUD FOUND message appears on the LCD screen, slow down and keep sliding until

EDGE message appears and beep sounds as shown in 

Figure 3

. This is the stud edge. Mark

this spot (at arrow on lower part of unit).

5). Keep moving past mark until EDGE and STUD FOUND disappear.

6). Continue holding detector button and reverse direction. 

7). Find and mark other stud edge, following step 4).

8). Center of the stud is between marks.

AC WIRE SENSING

Test on a known “live” AC wire before each use. For AC Detection up to 1-1/2 inches (38mm)

from the surface. The sensor detects AC voltage and will identify only live wires. AC voltage

detection feature works continuously when detecting studs. It assists in identifying when the

sensor is near live AC wiring and detector button (B) is depressed. Once AC voltage has

been detected AC wire indicator LED (C) will light. 

If the unit is calibrated close to AC wire, it may decrease AC wiring sensor sensitivity. Static

charge may spread detection 12 inches (30.4cm) on both sides of wire. 

WARNING:

Occasionally, pipes and electrical wiring may not be detected by this product.

Observe caution when cutting or drilling into areas that may contain concealed pipes or

wiring. The sensor will not detect live wires inside metal pipe or metal conduit, behind

metallic wall covering, or behind some plywood or other dense materials. 

Use caution if area has plywood, thick wood backing behind drywall, or thicker than normal

walls.

WARNING: 

Always turn off the power when working near electrical wires, electric

shock may result.

AUTO LEVELING LASER LINES

Operation of Laser:

Place unit flat against wall as shown in

Figure 1

. Move laser on/off

button (A) to "I" position to actuate the auto leveling horizontal laser lines.

HANGING ON DRYWALL SURFACES ONLY

Hands Free Operation of Laser: 

To hang the unit on a wall, remove the orange protective

cap from the drywall pin (F) and store it on the cone as shown in 

Figure 4

. Push pin into

drywall (

Figure 5

). When pressing pin into drywall, make sure it is straight and seated firmly.

Hang the laser on the cone as shown in 

Figure 6

and check to make sure that the unit is

secure on the wall. 

Figure 7

illustrates a typical application for the laser when it is wall

mounted.

CAUTION:

Pin is sharp and should be handled with care. The drywall pin should always be

pushed in by hand and never driven by a hammer. Replace protective cap after each use. 

NOTE:

The pin is only for use on drywall NOT other surfaces including plaster.

HANGING ON OTHER SURFACES

Hands Free Operation of Laser:

For surfaces other than drywall, the (key hole) hanging

cone (E) can be used with a standard nail or screw in a predrilled hole. To use the keyhole

hanging cone, place it over a nail or screw on a vertical surface with the narrow portion of the

opening pointing upward. Push the laser onto the hanging cone until it snaps into place. To

remove the laser, lift it slightly and pull it straight off. The unit can also be used with the

hanging cone attached to the back and then hanging the unit on the nail or screw. Make sure

it is straight and seated firmly on the cone and that the unit is secure on the wall.

DANGER: Laser Radiation, avoid direct eye exposure.

Helpful Hints

If the laser light becomes dim or is no longer visible when the switch is in the on position

check or change the battery.

The laser lines are only level on the wall against which the unit is held or hung. The short

line visible on any adjacent wall is not level.

The laser unit is a wall use tool only and only generates level lines when held against a

vertical surface.

The laser unit is equipped with a pendulum lock that stops pendulum motion when the laser

on/off switch is moved to the off position.

If the laser on/off switch is pushed part way to the on position, the laser lines may be on

while the pendulum lock is still engaged.

Hold stud sensor straight up and down.

For your convenience and safety, the following labels are on your laser.

Helpful Hints (Con’t).

Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches wide, 

beware of anything closer together or of a different width. Doors and windows are

constructed with studs and headers which are closer together.

When using unit over a stucco wall, place a piece of cardboard over the surface to help

provide a smooth motion across the wall. 

Avoid materials which have inconsistent density such as:

 Carpeting and padding

 Ceramic floor tile

 Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular 

wallpaper or fabric will scan with no difference in function.

 Walls that are freshly painted and are still damp.

 Excessively thick plaster and lath. 

Storage

Always store this product indoors 

Maintenance

Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool;

never immerse any part of the tool into a liquid.

IMPORTANT:

To assure product SAFETY and RELIABILITY, repairs, maintenance and

adjustment (other than those listed in this manual) should be performed by authorized service

centers or other qualified service organizations, always using identical replacement parts.

Accessories

WARNING: 

The use of any accessory not recommended for use with this tool could be

hazardous.

SERVICE INFORMATION

All Black & Decker Service Centers are staffed with trained personnel to provide customers

with efficient and reliable power tool service. Whether you need technical advice, repair, or

genuine factory replacement parts, contact the Black & Decker location nearest you. To find

your local service location, refer to the yellow page directory under "Tools—Electric" or call: 

 or visit www.blackanddecker.com.au

Laser Diode Wavelength:        

650 ± 5 nm (red color)

Laser Class:

Class IIIa

Working Range:

Up to 20 feet (depends on light conditions)

Leveling Accuracy:

±1/8 inch (3 mm) @ 10 feet (3 m)

Auto Leveling Range:

±4.5°

Auto Leveling Lines Settling Time: <5 sec

Batteries:

2 AA Alkaline (included)

Voltage:

3 Volt

Operating Temperature:

50°F (10°C)- 104° F (40°C)

DANGER

PELIGRO

Possible Cause

 Weak battery.

 Nothing to detect in that

area.

 Check mode. May

have been calibrated

over a stud. 

Solution

 Replace with fresh battery.

 Start again moving farther to

either side.

Problem

 Unit not detecting any

studs in search area.

 Because studs are normally

spaced 16 inches or 24 inches

apart and are 1-1/2 inches wide,

beware of anything closer together

or of a different width.

 Unit found too many

studs in search area.

 Detects other objects

besides studs.

 Electrical wiring and

metal or plastic pipes

may be near or touching

back surface of wall.

T

T

R

R

O

O

U

U

B

B

L

L

E

E

S

S

H

H

O

O

O

O

T

T

I

I

N

N

G

G

 Replace with fresh battery.

 Be sure that the unit is as straight

up and down as possible.

 Laser does not project

on wall.

 Weak battery.

 The self leveling range

of the unit is +/-5

degrees, if the unit is not

held within 5 degrees of

vertical, the laser lines

will not project on wall.

 Laser projects on wall

but lines are not level.

 Wall on which the unit

is mounted or held must

be /- 5 degrees

of vertical for the self

leveling mechanism to

function correctly. If this

is exceeded, the lines

will still project but may

not be level.

 The laser on/off switch

must be pushed to the

full on position.

 Use the unit against vertical walls

only, lines will not be level on

sloped walls or other non-vertical

surfaces.

 Be sure laser on/off switch is in

the full on position.

 Replace with fresh battery.

 If a switch controls an outlet, make

sure the it is ON for detection.

 You suspect electrical

wires, but do not detect

any.

 Weak battery.

 If wires are shielded

behind metallic wall

coverings, or in metal

conduit, the sensor will

not be able to detect

them.

 The wires may not be

“live”.

 Wires may be too deep

to sense.

 Use caution if area has

plywood, thick wood

backing behind drywall,

or thicker than normal

walls.

WARNING:

Always turn off the power when working near electrical wires.

LASER RADIATION. AVOID DIRECT EYE EXPOSURE.

RADIACI”N L¡ SER. EVITE LA EXPOSICI”N DIRECTA DE LOS OJOS.

MAXIMUM OUTPUT POWER< 5mW@633nm-670nm CLASS IIIa LASER PRODUCT. THIS PRODUCT

COMPLIES WITH THE APPLICABLE REQUIREMENTS OF 21CFR PARTS 1040.10 AND 1040.11.

L¡ SER CLASE IIIa CON M¡ XIMA POTENCIA DE SALIDA < 5mW@633nm-670nm. ESTE PRODUCTO 

CUMPLE CON LOS REQUISITOS APLICABLES DE LAS PIEZAS 1040.10 Y 1040.11 DE 21CFR.

DANGER

PELIGRO

WARNING/ADVERTENCIA/AVERTISSEMENT

To reduce the risk of injury, user must read and 

understand instruction manual. Para reducir el riesgo 

de lesiones, el usuario debe leer y entenderel manual 

de instrucciones. ¿ titre prÈventif, lire le guide.

AC WIRE DETECTION

Only life AC wires could be detected. AC voltage detection feature works

continually when detecting studs. Once AC voltage detected AC wire

indicator LED will light. (see instruction manual).

LASER RADIATION. AVOID DIRECT EYE EXPOSURE.

RADIACI”N L¡ SER. EVITE LA EXPOSICI”N DIRECTA DE LOS OJOS.

MAXIMUM OUTPUT POWER< 5mW@633nm-670nm CLASS IIIa LASER PRODUCT. THIS PRODUCT

COMPLIES WITH THE APPLICABLE REQUIREMENTS OF 21CFR PARTS 1040.10 AND 1040.11.

L¡ SER CLASE IIIa CON M¡ XIMA POTENCIA DE SALIDA < 5mW@633nm-670nm. ESTE PRODUCTO 

CUMPLE CON LOS REQUISITOS APLICABLES DE LAS PIEZAS 1040.10 Y 1040.11 DE 21CFR.

DANGER

PELIGRO

WARNING/ADVERTENCIA/AVERTISSEMENT

To reduce the risk of injury, user must read and 

understand instruction manual. Para reducir el riesgo 

de lesiones, el usuario debe leer y entenderel manual 

de instrucciones. ¿ titre prÈventif, lire le guide.

AC WIRE DETECTION

Only life AC wires could be detected. AC voltage detection feature works

continually when detecting studs. Once AC voltage detected AC wire

indicator LED will light. (see instruction manual).

Imported by

 

 

4

2

2

-

4

44

4

-

0

0

8

-

1

TECHNICAL SPECIFICATIONS OF LASER LEVEL: