background image

7

Charge Rate Selection

After charger clamps are correctly connected, plug the charger into a 120 volt AC outlet and the charger will
show “000” on the Digital Display, indicating power has been applied. Select the proper charge current rate
based on battery size. Press the 4/10/20/40 AMP button and the charger will begin charging at 4 amps.
Pressing the 4/10/20/40 AMP button again will advance the charge rate to 10 amps, again to 20 amps, and
again to 40 amps. Pressing the switch again will turn OFF the charger output and the display will show “000”.

Note: 

The only time the selected charge rate does not display at the full selected rate is when the battery is

nearly full and charging at either step two or three. The display will show a reduced charge rate. To return to
4A, press the 4/10/20/40 amp button. When the battery is fully charged, “FUL” shows on the Digital Display.

WARNING: 

If Digital Display shows “F02”, the connection to the battery terminals is bad. Follow the steps

outlined in “Important Safety Instructions” at the front of this manual to disconnect, clean battery terminals,
then reconnect.
If Digital Display shows “F06”, the Red (Positive) and Black (Negative) clamps are incorrectly connected to
battery terminals. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to
disconnect, then reconnect in correct polarity.

Charging the Battery

1. Press Battery Type selector until desired battery type LED lights.

Note:

The default selection is “GEL” type battery.

2. Press 4/10/20/40 AMP button to begin charging at the 4 amp rate; the unit sounds a beep and displays

charging current. The charger starts charging at 4 amp rate automatically if 4/10/20/40 AMP button is not
pressed within 3 minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the battery is sulfated and the charger is
trying to give it some charge. If after approximately 3 hours the display just shows “F03”, then the battery will
not charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or charging stage changes.

3. Pressing the 4/10/20/40 AMP button again advances charging rate to 10 amps. Pressing once more

advances charging rate to 20 amps, and again to 40 amps. (Pressing the button again will turn OFF the charger
output and the Display will show “000”.) This selection and actual battery charge rate are monitored by the
microprocessor, and the unit will stop charging if the selected rate is too fast or too slow for battery size or
condition.
As the battery nears full charge capacity, the unit’s output will automatically drop to a lower charge rate.
Pressing the 4/10/20/40 AMP button repeatedly advances to standby mode; the unit sounds a beep, displays
“000” and stops charging.

4. The battery charger displays the charge current. To view the battery voltage, press BATTERY VOLTAGE

button. The charger will sound a beep and display the battery voltage. Press the BATTERY VOLTAGE button
again to return to displaying the charge current.

5. The display shows “FUL” when the battery is fully charged.
6. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect.

Automatic Float Charging

Automatic Float Charging is ideal for maintaining a fully charged battery.

1. Keep the AC power and battery connected after battery is fully charged.
2. The charger monitors the battery and tops it off as needed.
3. The Float Charge indicator lights and the display shows charge current when topping off the battery and

returns to “FUL” when completed.

4. To view battery voltage, press the Battery Voltage button.

Note:

Charging can be terminated by pressing the charge rate selector button at any time when unit is

charging. After AC power interruption, charging restarts at 4 amp rate automatically and the battery type will
default to “GEL”.

WARNING:

If battery size is not known, charge at the 4 amp rate. DO NOT overcharge batteries. 

Equalizing

Equalizing is the process by which the fluid in each of a battery’s cells is equalized. This process occurs after
charging is complete.

BC40EB_ManualEN_051707.qxp  6/4/07  2:54 PM  Page 7

Содержание BC25EB

Страница 1: ...NG THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER SAVE THIS MANUAL FOR FUTURE REFERENCE Cat BC40EB Form 90516444 May 07 Copyright 2007 Black Decker Printed in ...

Страница 2: ...LT CIRCUIT INTERRUPTER GFCI protection should be provided on the circuits or outlets to be used Receptacles are available having built in GFCI protection and may be used for this measure of safety USE OF ACCESSORIES AND ATTACHMENTS The use of any accessory or attachment not recommended for use with this appliance could be hazardous Note Refer to the accessory section of this manual for further det...

Страница 3: ...operate unit with damaged cord or plug or if the unit has received a sharp blow been dropped or otherwise damaged in any way Do not disassemble the unit take it to a qualified service technician when service or repair is required Incorrect reassembly may result in a risk of electric shock or fire and will void warranty Use of an attachment not supplied recommended or sold by manufacturer specifica...

Страница 4: ...cian Improper connection can result in a risk of an electric shock Preparing to Charge 1 Determine voltage of battery to be charged by referring to the vehicle manual 2 it is necessary to remove battery from vehicle to charge or to clean terminals always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc 3 Clean battery terminals ...

Страница 5: ...d POS P or red 4 Stand as far back from the battery as possible and do not face battery when making final connection 5 Carefully connect the NEGATIVE BLACK charger clamp to the free end of the battery cable connected to the negative terminal 6 Set the charge rate to appropriate setting according to battery size 7 When disconnecting charger always do so in reverse sequence of connecting procedure a...

Страница 6: ...ic Temperature Compensation Battery type selection Digital diagnostics Alternator voltage and battery voltage check Digital display shows charge rate operating mode fault codes and FUL when charged 1 minute engine start 3 stage high frequency switch mode automatic rapid charging Spark resistant reverse polarity and short circuit protection for user Built in battery reconditioning desulfate Lightwe...

Страница 7: ... a battery to maintain its charge over long periods of non use If there is any loss of power to the charger once power is restored charger will automatically return to the default settings Battery selector type would be gel Battery Voltage lights when battery voltage is displayed Alternator Good lights when load or no load checks show the alternator is keeping up with the electrical load Equalize ...

Страница 8: ... display just shows F03 then the battery will not charge Charger occasionally sounds a beep and displays 0 0 during self test or charging stage changes 3 Pressing the 4 10 20 40 AMP button again advances charging rate to 10 amps Pressing once more advances charging rate to 20 amps and again to 40 amps Pressing the button again will turn OFF the charger output and the Display will show 000 This sel...

Страница 9: ...5 2 7v per cell depending on ambient temperature it will automatically adjust 13 The WET LED flashes while the charger is in equalize mode 14 The digital readout will show FUL when the equalization process is complete Engine Start The Engine Start function can supply 110 amps for engine starting 1 Set the 4 10 20 40 AMPS button to 40 amp mode and immediately press the 110A button switch to activat...

Страница 10: ...failure or possibly bad connections between the battery and alternator and or ground Notes BATTERY VOLTAGE button is disabled in Alternator Check mode F07 may display because someone has added a number of accessory loads on the charging system thereby increasing current demand from the alternator MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION This check may not be accurate for e...

Страница 11: ...nit to cool for 30 minutes and reconnect Make sure there is ample ventilation before resuming operation F06 Reverse Polarity The connections to the battery s positive and negative terminals are incorrect Follow the steps outlined in Important Safety Instructions at the front of this manual to disconnect AC cord and clamps and reconnect to battery with correct polarity F07 Alternator Voltage Altern...

Страница 12: ...pecific legal rights and you may have other rights which vary from state to state or province to province Should you have any questions contact the manager of your nearest Black Decker Service Center This product is not intended for commercial use FREE WARNING LABEL REPLACEMENT If your warning labels become illegible or are missing call 1 800 544 6986 for a free replacement SPECIFICATIONS Input 12...