background image

Model # 900149: Page 9 

 

PROPER CARE & CLEANING 

 

General Cleaning 

Perform: As needed 
Time Required: 5 minutes. 
Note: Do NOT use abrasive materials or chemical cleaners. 
 
1.  Clean cabinet surfaces with a soft cloth and warm soapy water.  
2.  Wipe dust from back of dispenser to improve efficiency. 
3.  Remove drip tray assembly by sliding it forward. Remove cover. Place tray and 

cover in dishwasher or wipe parts clean with a soft cloth and warm soapy water.  

 
Cleaning Water Tanks and Lines 

Perform:  Every 3 months or whenever an off-taste occurs. 
Time Required: 30 minutes. 
Requires: (1) empty 5 gallon bottle, (1) 2 gallon or larger bucket, clean cloths and 
unscented household bleach. 
Note: Best to do prior to loading a fresh bottle. 
 

Step A: Remove Existing Water 

1.  Move dispenser away from wall and turn it 90

°

 in either direction. 

2.  Turn energy saving switches to OFF. 
3.  Unplug power cord from wall outlet. 
4.  Remove water bottle and disconnect probe. 
5.  Place a 2 gallon or larger bucket under the drain plug 

in the rear of the dispenser.  

6.  CAUTION: Remove drain cap and silicon plug. Cold 

water will immediately flow into the bucket. Several 
seconds’ later hot water will dispense. 
Reminder - Place drain cap and silicon plug in a safe 
location so they are not lost. 

7.  Once unit has drained, replace silicon plug and drain 

cap. 

8. Remove 

remaining 

water from reservoir by 

dispensing from the cold and cool taps into a pitcher. 

 

Step B: Sanitize Probe and Taps

 

1.  In a clean bucket, make a sanitizing solution of one gallon tap water and 3 

tablespoons of unscented household bleach. 

Содержание 900149

Страница 1: ...tled Water Dispenser Model 900149 USER MANUAL PN O 035 2009 Primo Water Corporation TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE USER MUST READ THIS MANUAL BEFORE ASSEMBLING INSTALLING OPERATING DISPENSER SAVE THIS MANUAL FOR FUTURE USE ...

Страница 2: ...sunlight Do NOT use outdoors Install and use only on a hard flat and level surface Do NOT place dispenser into an enclosed space or cabinet Do NOT operate dispenser in the presence of explosive fumes Position back of dispenser no closer than 4 inches from wall and permit free airflow between wall and dispenser There must be at least 4 inches clearance on the sides of the dispenser to permit airflo...

Страница 3: ...ited Warranty 12 KEY INFORMATION FOR FUTURE USE Please register your dispenser immediately at www primowater com For future support please record your serial number located on label on back of dispenser and date purchased Staple your receipt to manual You will need this information to obtain warranty service Product Bottom Loading Bottled Water Dispenser Model Number 900149 Serial ID Number Date o...

Страница 4: ... 149 F 199 F Dimensions 40 5 inches H x 12 6 inches W x 15 0 inches D Net Weight 35 3 lbs PARTS FEATURES Energy Saving Switch Cold Front Back LED Nightlights Bottle Tray Inside Bottle Probe Inside Cabinet Hot Water Control Hot Water Release Hot Water Tap Cold Water Tap Drip Tray 1 2 3 4 5 6 7 8 9 11 Drain Plug Carry Handle Power Cord 1 2 3 4 5 6 7 8 9 13 15 10 14 12 13 14 Cold Water Control 12 15 ...

Страница 5: ...d location near a grounded wall outlet 3 Position dispenser so the back is at least 4 inches from wall and there are at least 4 inches of clearance on both sides 4 To minimize vibration and noise make sure dispenser is level Notice Do NOT plug in power cord yet OPERATION This unit is intended for water dispensing only Do NOT use other liquids Do NOT use for other purposes This dispenser has been d...

Страница 6: ... gallon bottle remove sections C B Save for future use 3 Install bottle Open door and place fresh bottle in front of tray Clean fresh bottle with a soft cloth and warm soapy water then rinse Remove entire plastic cap from top of bottle Insert probe into bottle Push down on probe until it is seated Create a seal by turning handle clockwise until tight do NOT over tighten Slide bottle onto tray and ...

Страница 7: ...the taps the pump will come on to refill the tanks This is normal Initial Rinsing of Water Lines This unit has been tested and sanitized prior to packing and shipping During transit dust and odors can accumulate in the tank and lines Dispense and dispose at least one quart of water from cool and cold taps prior to drinking any water Dispensing Cold Water Note After setup it will take 1 hour to get...

Страница 8: ...Release control once desired fill level is achieved Replacing an Empty Bottle Notice When your bottle is empty the dispenser will beep 3 times and the LED nightlights will blink until a fresh bottle is connected You may also hear a sucking sound when the bottle empties This is normal and is another way to be alerted that your bottle is empty Replace empty bottle as soon as you notice it is empty T...

Страница 9: ...o do prior to loading a fresh bottle Step A Remove Existing Water 1 Move dispenser away from wall and turn it 90 in either direction 2 Turn energy saving switches to OFF 3 Unplug power cord from wall outlet 4 Remove water bottle and disconnect probe 5 Place a 2 gallon or larger bucket under the drain plug in the rear of the dispenser 6 CAUTION Remove drain cap and silicon plug Cold water will imme...

Страница 10: ...ir by dispensing from the cold and cool taps into a pitcher Step D Rinse Reservoirs 1 Dispose of sanitizing solution and rinse bottle with tap water 2 Fill the bottle with tap water and insert probe into bottle 3 Push down on probe until it is seated 4 Create a seal by turning handle clockwise until tight do NOT over tighten 5 Slide bottle into cabinet and close door 6 Plug power cord into a groun...

Страница 11: ...after setup to secure cold water Make sure the back of the dispenser is at least 4 inches from a wall and there is free airflow on all 4 sides of the dispenser Make sure energy saving switch is ON Hot water is not hot It takes 15 20 minutes after setup to secure hot water Make sure the power cord is properly connected to a working outlet Make sure energy saving switch is ON Dispenser is noisy Make...

Страница 12: ...suse alteration misapplication improper installation or improper maintenance or service by you or any third party or failure to perform normal and routine maintenance on the dispenser as set out in the User s Manual In addition the Limited Warranty does not cover damages to the finish such as scratches dents discoloration or rust after purchase The Limited Warranty is in lieu of all other express ...

Страница 13: ...66 429 7566 para recibir asistencia Dispensador de agua con carga por la parte inferior Modelo no 900149 MANUAL DEL USUARIO PARA REDUCIR EL RIESGO DE LESIONES Y DAÑOS MATERIALES EL USUARIO DEBE LEER ESTE MANUAL ANTER DE ENSAMBLAR INSTALAR Y USAR EL DISPENSADOR GUARDAR ESTE MANUAL PARA USO FUTURO PN O 035A 2009 Primo Water Corporation ...

Страница 14: ...s Instalar y usar únicamente sobre superficies duras niveladas y planas NO instalar el dispensador en espacios o gabinetes cerrados NO use este dispensador en presencia de gases explosivos Posicionar la parte posterior del dispensador a una distancia de por lo menos 4 pulgadas 10 cm de la pared para permitir el flujo de aire entre la pared y el dispensador Debe haber por lo menos 4 pulgadas 10 cm ...

Страница 15: ...do y limpieza 9 Resolución de problemas 11 Garantía limitada 12 INFORMACIÓN IMPORTANTE PARA USO FUTURO Por favor registre su dispensador inmediatamente en www primowater com Para servicio futuro por favor registre su número de serie ubicado en la etiqueta situada en la parte posterior del dispensador y fecha de compra Engrape su recibo al manual Necesitará esta información para obtener servicio de...

Страница 16: ...litros Rango temp caliente 149 F 199 F 65 C 93 C Dimensiones 40 5 pulgadas de alto x 12 6 pulgadas de ancho x 15 pulgadas de largo 102 8 cm x 32 cm x 38 2 cm Peso neto 35 3 libras 16 kg PIEZAS Y CARACTERÍSTICAS Interruptor de ahorro de energía Fría Frente Atrás Grifo agua fría Interruptor de ahorro de energía Caliente Sonda de botellón dentro del gabinete Control agua caliente Botón liberador de a...

Страница 17: ... dura y nivelada en una ubicación protegida y fresca cerca de un tomacorriente con conexión a tierra 3 Coloque el dispensador de modo que la parte posterior esté a una distancia de por lo menos 4 pulgadas 10 cm de la pared y que ambos lados tengan un espacio libre de por lo menos 4 pulgadas 10 cm 4 Para minimizar la vibración y el ruido asegúrese de que el dispensador esté nivelado Aviso Todavía N...

Страница 18: ...sección C Guárdela para uso futuro Si esta usando un botellón de 3 galones 11 3 litros retire las secciones C y B Guárdelas para uso futuro 3 Instale el botellón Abra la puerta y coloque un botellón nuevo en frente de la bandeja Limpie el botellón nuevo con un paño suave y aja jabonosa tibia luego enjuague Quite del botellón la tapa de plástico completa Inserte la sonda dentro del botellón Presion...

Страница 19: ...o la bomba se encenderá y apagará Esto es normal Cada vez que dispense agua de los grifos la bomba se encenderá para rellenar los tanques Esto es normal Enjuague inicial de las líneas de agua Esta unidad ha sido probada y desinfectada antes de su empaque y envío Sin embargo es posible que durante el transporte se acumulen polvo y olores en el tanque y en las líneas Dispense y deseche por lo menos ...

Страница 20: ... abajo para empezar el flujo 3 Suelte el control una vez que se alcance el nivel de agua deseado Reemplazar un botellón vacío Aviso Cuando el botellón esté vacío el dispensador emitirá un pitido 3 veces y parpadearán las luces LED nocturnas hasta que se conecte un botellón nuevo También podría escuchar un sonido de succión cuando el botellón esté vacío Esto es normal y es otra manera de indicarle ...

Страница 21: ... 1 botellón de 5 galones 18 9 litros vacío 1 cubo de 2 galones 8 litros o más grande paños limpios y lejía de uso doméstico sin aroma Aviso Es mejor hacer la desinfección antes de cargar un botellón nuevo Paso A Extraiga el agua existente 1 Mueva el dispensador lejos de la pared y gírelo 90 en cualquier dirección 2 Mueva los interruptores de ahorro de energía a la posición OFF apagado 3 Desenchufe...

Страница 22: ...a y lejía llene los depósitos vacíos 8 Espere 10 minutos y luego coloque los interruptores de ahorro de energía en la posición OFF apagado y desenchufe el cable eléctrico 9 Coloque un cubo de 2 galones 8 litros o más grande debajo del tapón de drenaje situado en la parte posterior del dispensador 10 PRECAUCIÓN Quite la tapa de drenaje y el tapón de silicona Fluirá inmediatamente agua fría en el cu...

Страница 23: ...CIÓN Extraiga la tapa de drenaje y el tapón de silicona Inmediatamente fluirá agua fría al cubo Varios segundos después se dispensará el agua caliente Recordatorio Coloque la tapa de drenaje y el tapón de silicona en un lugar seguro para que no se pierdan 11 Una vez que se haya drenado la unidad vuelva a colocar el tapón de silicona y la tapa de drenaje 12 Extraiga l agua restante del depósito dis...

Страница 24: ... encendido Asegúrese de que la parte posterior del dispensador esté a una distancia de por lo menos 10 cm de la pared y que haya espacio libre a los cuatro lados del dispensador Asegúrese de que el interruptor de ahorro de energía esté en la posición ON encendido El agua caliente no está caliente Calentar el agua demora de 15 a 20 minutos después del encendido Asegúrese de que el cable eléctrico e...

Страница 25: ...miento o servicio inapropiado o falla en la realización de mantenimiento normal y rutinario del enfriador de agua como se prescribe en este manual del usuario Además la garantía limitada no cubre daños al terminado de la unidad tales como rasguños abolladuras descoloridos oxidaciones y otros daños causados por la intemperie después de la compra de la unidad Esta garantía limitada reemplaza cualqui...