Resistive loads are the easiest for the inverter to run; however, it will not run larger resistive loads (such as
electric stoves and heaters), which require far more wattage than the inverter can deliver. Inductive loads (such
as TVs and stereos) require more current to operate than do resistive loads of the same wattage rating.
For safety reasons, the unit will simply shut down if it is overloaded. To restart the unit, simply unplug all
devices plugged into the unit; disconnect the unit from any 12 volt DC power source; then reconnect the unit
BEFORE plugging the appliance back in.

Operation of the 115 Volt AC Outlet

1. Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual. If

using the 12 Volt DC Vehicle Accessory Adapter, rotate the vehicle accessory plug slightly to make sure there
is good contact. Make sure there is adequate space for proper ventilation of the inverter.

2. Press the Power Pushbutton to turn the unit ON.
3. The green Power LED Indicator will light, indicating a proper connection. If the either the yellow Input Fault

LED Indicator or red Output Fault LED Indicator lights, indicating a fault condition exists, refer to the
“Troubleshooting” section of this Instruction Manual.

4. If the Inverter does not work, make sure the ignition/accessory switch is actually powering the accessory

outlet. Some vehicles require the ignition switch to be turned on.

5. Plug the (110/120 volt AC) appliance into the Inverter’s three-prong AC outlet and operate normally.

Note: The Inverter will not operate appliances and equipment that generate heat, such as hair dryers,

electric blankets, microwave ovens and toasters.
Remember to disconnect the inverter from any power source when not in use.

Operation of the USB Charging Port

1. Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual. If

using the 12 Volt DC Vehicle Accessory Adapter, rotate the vehicle accessory plug slightly to make sure there
is good contact.  Make sure there is adequate space for proper ventilation of the inverter.

2. Press the Power Pushbutton to turn the unit ON.
3. The green Power LED Indicator will light, indicating a proper connection. If the either the yellow Input Fault

LED Indicator or red Output Fault LED Indicator lights, indicating a fault condition exists, refer to the
“Troubleshooting” section of this Instruction Manual.

4. If the inverter does not work, make sure the ignition/accessory switch is actually powering the accessory

outlet. Some vehicles require the ignition switch to be turned on.

5. Plug the USB-powered device into the inverter’s USB Charging Port and operate normally.

Note: This unit’s USB Charging Port does not support data communication. It only provides 5 volts/300mA DC

power to an external USB-powered device.
Remember to disconnect the inverter from any power source when not in use.

Operation of the 12 Volt DC Outlet

1. Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual. If

using the 12 Volt DC Vehicle Accessory Adapter, rotate the vehicle accessory plug slightly to make sure there
is good contact.

2. Press the Power Pushbutton to turn the unit ON.
3 The green Power LED Indicator will light, indicating a proper connection. If the either the yellow Input Fault

LED Indicator or red Output Fault LED Indicator lights, indicating a fault condition exists, refer to the
“Troubleshooting” section of this Instruction Manual.

4 If the inverter does not work, make sure the ignition/accessory switch is actually powering the accessory

outlet. Some vehicles require the ignition switch to be turned on.

5. Plug the 12 volt DC-powered device into the inverter’s 12 Volt DC Power Port and operate normally.

Note: Do not attempt to use this unit to power appliances that draw more than 8 amps.

Remember to disconnect the inverter from any power source when not in use.

Protective Features

The inverter monitors the following conditions:
Low Battery Voltage — This condition is not harmful to the inverter, but could damage the power source, so the
inverter will automatically shut down when input voltage drops below 10.5 ± 0.3 volts DC.
Input Voltage Too High — The inverter will automatically shut down when DC input voltage exceeds 15.5 ± 0.5
volts, as this can harm the unit.
Thermal Shutdown Protection — The inverter will automatically shut down when the unit becomes overheated.
Overload/Short Circuit Protection — The inverter will automatically shut down when a short circuit occurs.

6

PI200AB_ManualEN_060807.qxp  6/8/2007  4:48 PM  Page 6

Содержание 200 WATT

Страница 1: ... INSTRUCTION MANUAL Catalog Number PI200AB BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 877 571 2391 BEFORE YOU CALL HAVE THE CATALOG No AVAILABLE IN MOST CASES A REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in PROPER COOLING is essential when operating the inverter Do not place the unit near the vehicle s heat vent or in direct sunlight ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used Receptacles are available having built...

Страница 3: ...udes DC cigarette lighter type plug connection This unit is NOT approved for ignition protected areas NEVER immerse the unit in water or any other liquid or use when wet Do not insert foreign objects into the AC outlet or the USB outlet WARNING TO REDUCE THE RISK OF FIRE Do not operate near flammable materials fumes or gases DO NOT expose to extreme heat or flames CAUTION TO REDUCE THE RISK OF INJ...

Страница 4: ...panel provides three LED indicators The green LED indicates power and proper operation of the inverter The AC and USB outlets are ready to use The red LED indicates inverter shutdown from an over load or over temperature fault and the yellow LED indicates an input fault If the red or yellow Fault LED Indicator lights refer to the Troubleshooting Section of this Instruction Manual The Power Pushbut...

Страница 5: ...87 Fluke 8080A Beckman 4410 or Triplett 4200 115 Volt AC Output CAUTION Rechargeable Devices Certain rechargeable devices are designed to be charged by plugging them directly into an AC receptacle These devices may damage the inverter or the charging circuit When using a rechargeable device monitor its temperature for the initial ten minutes of use to determine if it produces excessive heat If exc...

Страница 6: ...s are lit and that no flammable fumes are present in the installation area 2 Identify the POSITIVE and NEGATIVE DC power source battery terminals 3 Install a fuse holder or breaker close to the POSITIVE terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end of the wire to the POSITIVE terminal of the inverter 5 Connect a...

Страница 7: ...dicator will light indicating a proper connection If the either the yellow Input Fault LED Indicator or red Output Fault LED Indicator lights indicating a fault condition exists refer to the Troubleshooting section of this Instruction Manual 4 If the inverter does not work make sure the ignition accessory switch is actually powering the accessory outlet Some vehicles require the ignition switch to...

Страница 8: ...pe TROUBLESHOOTING Common Audio Visual Problems Problem Buzzing Sound In Audio Systems Some inexpensive stereo systems and boom boxes make a buzzing sound when operated from the inverter because the power supply in the electronic device does not properly filter the modified sine wave produced by the inverter The only solution to this problem is to use a sound system that has a higher quality power...

Страница 9: ...5 t u p t u O B S U s p m a 8 t e l t u O C D s t l o v 8 2 1 e g a t l o V t u p n I Output Voltage Approx 115 volt AC RMS 60 Hz Low Voltage Alarm 10 7 volts DC Low Voltage Shutdown 10 5 0 3 volts DC Thermal Shutdown Automatic W S M e v a W e n i S d e i f i d o M m r o F e v a W Output Connection North American Standard Receptacles s p m a 8 g u l P y r o s s e c c A C D l a n r e t n I s e s u ...

Отзывы: