BKT ACBS

 

Access Control Bus System 

- the access control system with RS485 bus interface 
 
 
- installation and configuration manual 
- version 5 
 
 
 
 
 

 

 
 
 

Содержание ACBS

Страница 1: ...wska 69 Str 86 005 Biale Blota Phone 48 52 36 36 750 e mail export bkte pl 2022 BKT Elektronik www bkte pl BKT ACBS Access Control Bus System the access control system with RS485 bus interface installation and configuration manual version 5 ...

Страница 2: ...lling 34 5 7 Installation of cabinet door wiring 35 5 8 Diagram of functional circuits for operating the cabinet door 38 6 INSTALLATION OF COLD HOT AISLE CONTAINMENT SLIDING DOOR DEVICES 39 6 1 AC100 controller installing 39 6 2 AR122 AR132 readers installing 39 6 3 Installing exit button and emergency button 39 6 4 Installing optional exit buttons 40 6 5 Installing sliding doors wiring 40 6 6 Con...

Страница 3: ...of the access control system with RS485 bus interface 3 9 8 Two user entry 67 9 9 Open door signalling with LED 68 9 10 Tamper signalling 74 9 11 Emergency button use signalling 81 9 12 Adding user group 87 9 13 Adding user to group 88 10 DOCUMENT REVISIONS 92 ...

Страница 4: ...ms use Roger RACS5 devices This manual contains basic information sufficient to run the BKT ACBS access control system More technical information about the devices used in the system can be found at www roger pl en 1 3 Basic system functionality Supports unlimited number of cabinets Supports unlimited number of users subject to a maximum of 8192 per controller Supports different card standards dep...

Страница 5: ...use the same Roger MC16 PAC controller so they can work in the same system managed by the same VISO ST application The table below lists the main differences between the system variants System structure Interface between the controller and the reader Supported standard of proximity cards Possibility of connecting a handle with an integrated reader AL301 Possibility of connecting any third party re...

Страница 6: ...network and RS485 bus connecting slave sets All connections to the controller are made with cables with RJ45 connectors The controller has two configurable LEDs which for example can indicate the status of the front and rear doors of the cabinet Two way power supply possible Requires one or two 12VDC 1 5A power supplies 3 1 1 Technical data Parameter Value Power supply voltage Nominal 12V DC allow...

Страница 7: ...ccessories Product Description Part number MC16 PAC x x door controller RACS5 122AC1020xx GST18A12 P1J Power supply 18W 12VDC 1 5A AC socket C14 DC plug 5 5 2 1 no AC cord 122AA100015 Power cord plug IEC 320 C13 10A plug DIN 49441 unischuko 16A 3x1 0 mm2 black 2m 11480784 2 Power cord plug IEC 320 C13 10A plug IEC 320 C14 10A 3x1 0 mm2 black 2m 11480785 2 ...

Страница 8: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 8 3 1 4 Controller wiring schematic ...

Страница 9: ...roller are made with cables with RJ45 connectors The controller has two configurable LEDs which for example can indicate the status of the front and rear doors of the cabinet Two way power supply possible Requires one or two 12VDC 1 5A power supplies 3 2 1 Technical data Parameter Value Power supply voltage Nominal 12V DC allowed 12 15V DC Average current consumption with no external devices 10 mA...

Страница 10: ... 2 3 AB101 secondary set accessories Product Description Part number GST18A12 P1J Power supply 18W 12VDC 1 5A AC socket C14 DC plug 5 5 2 1 no AC cord 122AA100015 Power cord plug IEC 320 C13 10A plug DIN 49441 unischuko 16A 3x1 0 mm2 black 2m 11480784 2 Power cord plug IEC 320 C13 10A plug IEC 320 C14 10A 3x1 0 mm2 black 2m 11480785 2 ...

Страница 11: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 11 3 2 4 Secondary set wiring ...

Страница 12: ...1 secondary set Length 5m terminated with RJ45 and 10 pin female connectors 244AW001110 AW113 Reader to housing sliding door controller connection cable 5m The cable is used to connect the reader AR122 AR132 to sliding door controller Length 5m terminated with RJ45 and 10 pin male connectors 244AW001130 Electrical junction box 86mm x 86mm x 39mm wall mount black IP55 122AA100006 RUD 1 USB RS485 in...

Страница 13: ...5cm long cable terminated with multi pin connectors to connect to the lock and cabinet controller It reads EM Unique 125kHz proximity cards reading range up to 7 cm Three LED indicators buzzer with adjustable sound level keyboard with backlight two function buttons detection of housing opening and detachment from the surface 12V 50mA power supply from a controller or a slave set Dimensions 153 x 4...

Страница 14: ...ated with multi pin connectors to connect to the sliding door controller and to the system controller The wiring arrangement is different than in the AR121 reader It Reads EM Unique 125kHz proximity cards reading range up to 7 cm Three LED indicators buzzer with adjustable sound level keyboard with backlight two function buttons detection of housing opening and detachment from the surface 12V 50mA...

Страница 15: ... 15cm long cable terminated with multi pin connectors to connect to the lock and cabinet controller It reads Mifare 13 56MHz proximity cards reading range up to 7 cm Three LED indicators buzzer with adjustable sound level keyboard with backlight two function buttons detection of housing opening and detachment from the surface 12V 85mA power supply from a controller or a slave set Dimensions 153 x ...

Страница 16: ...nated with multi pin connectors to connect to the sliding door controller and to the system controller The wiring arrangement is different than in the AR121 reader It reads Mifare 13 56MHz proximity cards reading range up to 7 cm Three LED indicators buzzer with adjustable sound level keyboard with backlight two function buttons detection of housing opening and detachment from the surface 12V 85mA...

Страница 17: ...ation 250mA Quiescent current consumption 90mA Dimensions 177 x 37 x 51 H x W x D 122AL002000 3 4 2 AL200 Dimensions 3 4 3 AL200 connectors 8 pin socket 53047 0810 1 GND Power supply input GND 2 12V Power supply input 12V 3 STATUS Handle status active low when handle open 4 CTRL Handle control 12V or GND to open the handle 5 SENSOR Do not connect 6 GND Do not connect 7 CANL Do not connect 8 CANH D...

Страница 18: ...ey in the event of a power failure Nominal current consumption during lock operation 200mA Quiescent current of the handle 50mA Dimensions 168 x 37 x 50 HxWxD 122AL103001 3 4 6 AL300 Dimensions 3 4 7 AL300 connectors 1 Power supply GND 2 Power supply 12V 3 N C 4 Control 12V to open handle 5 Electrical status active low when handle is open 6 Mechanical status active low when handle is open 3 4 8 AL...

Страница 19: ...th an RJ45 plug to connect to the controller The set has a metal bracket that fixes the reed switch to the cabinet frame 244AD001010 3 5 2 AD101 Door sensor wiring 3 5 3 AD102 Double leaf door sensor Product Description Part number AD102 Double leaf door reed sensor with 5m cable Sensors normally open NO 5m long wire terminated with an RJ45 plug to connect to the controller The set has a two metal...

Страница 20: ...AR122 AR131 AR132 with the AC1xx controller 5m long terminated with RJ45 plug and a 10 pin female connector 244AW001110 3 6 2 AW111 cable wiring 3 6 3 AW113 cable Product Description Part number AW113 Reader to housing sliding door controller connection cable The cable is used to connect the reader AR121 AR122 AR131 AR132 with the cold hot aisle containment sliding door controller 5m long terminat...

Страница 21: ... connect the reader AR121 AR131 to AL300 swinghandle Length 0 55m terminated with 10 pin male and 6 pin female connectors 244AW001120 3 6 6 AW112 cable wiring 3 6 7 AW212 cable Product Description Part number AW212 AL200 swinghandle to AR121 or AR131 reader connection cable 0 55m The cable is used to connect the reader AR121 AR131 to AL200 swinghandle Length 0 55m terminated with 10 pin male and 8...

Страница 22: ...selected logical automation nodes System control using remote commands Remote access authorization by VISO operators Automatic system reactions for selected events Configurable alerts for selected events E mail notifications Support for system administrator reader Wizards for quick system configuration The software is available for download at www roger pl 4 BKT ACBS SYSTEM STRUCTURE 4 1 System st...

Страница 23: ...t for a cold hot aisle containment made of six cabinets The system has been divided into two identical subsystems one for each row of cabinet a subsystem for cabinets 1 3 and a subsystem for cabinets 4 6 One of the cabinets has an AC100 controller installed with the MC16 PAC 7 controller pcb that supports up to 7 doors The remaining cabinets are equipped with AB101 secondary sets The secondary set...

Страница 24: ...er of doors supported by the controller Versions are available from MC16 PAC 1 for one door to MC16 PAC 16 for 16 doors The assembly of the pcb board should be performed in an environment free from electrostatic charges Hold the board only by its edges More information about the controller pcb itself can be found on the website www roger pl Open the controller housing cover by unscrewing the three...

Страница 25: ...onnectors on the terminal block It is enough to tighten only the connectors with the white description on the pcb the others are not used Connect the LAN connection patchcord Put the housing cover and tighten the screws 5 1 3 Installing in the cabinet Attach the 19 brackets to the housing using the provided four M3 screws two on each side ...

Страница 26: ...h the power supplies using plastic cable ties or Velcro ties Connect the 230VAC power cables and secure against disconnection by attaching a cable tie to the power supply holder Connect the 12VDC plugs of the power supplies to the sockets on the front panel Pay attention to the Rail A and Rail B markings Install the AC100 controller in the rack Suggested position at the top at the back of the cabi...

Страница 27: ...Screw the protective grounding conductor from the cabinet grounding bar to the device housing Connect the power supply cables to the power strips in the rack Pay attention to the proper connection to Rail A and Rail B Make connections of the other devices according to 5 1 4 Connecting devices to the AC100 controller ...

Страница 28: ...cord Local Ethernet network AW111 cable Front door reader AR121 or AR131 AW212 cable AL200 swing handle AW111 cable Front door reader AR121 or AR131 AW212 cable AL200 swing handle Front door sensor AD101 or AD102 Front door sensor AD101 or AD102 AW111 cable Sliding door reader AR122 or AR132 AW113 cable Sliding door controller Patch cords RJ45 RJ45 RS485 bus to the AB101 secondary boxes in next ca...

Страница 29: ... AW111 cable Front door reader AR121 or AR131 AW212 cable AL200 swing handle AW111 cable Front door reader AR121 or AR131 AW212 cable AL200 swing handle Front door sensor AD101 or AD102 Front door sensor AD101 or AD102 AW111 cable Sliding door reader AR122 or AR132 AW113 cable Sliding door controller Patch cords RJ45 RJ45 RS485 bus to the AC100 controller and AB101 secondary boxes in next cabinets...

Страница 30: ...Package contents Reader 3 M3 screws with nuts 5 3 2 Installing on the cabinet door Install the AR121 Unique or AR131 Mifare reader on the cabinet door in a designated place If the cabinet does not have a door dedicated to access control make the mounting holes as shown in the picture on the right Open the reader casing by unscrewing the screw at the bottom ...

Страница 31: ...th the controller and the door handle see 5 7 Installation of cabinet door wiring 5 4 AL200 swinghandle installing 5 4 1 Package contents AL200 swingahndle Fastening element with a screw Quick Start Guide 5 4 2 Installing on the cabinet door If the cabinet does not have an AL200 electronic handle pre installed install it in place of the mechanical handle Depending on the type of mechanical handle ...

Страница 32: ...interface 32 Unscrew the cam cylinder housing and then the cogwheel mechanism and remove the handle Pull out the rods so that in the closed position of the handle the rods are extended to the maximum Then place the electronic handle in the cut out in the door Screw in all the elements you just unscrewed ...

Страница 33: ...ontrol system with RS485 bus interface 33 Check if the handle mechanically closes the door properly 5 5 AL300 swinghandle installing Installation of the AL300 handle is similar to the AL200 handle Additional mechanical components including a cogwheel mechanism may be required ...

Страница 34: ...at secure the reed switches Attach the reed switch magnets to the cabinet door using the enclosed self adhesive double sided tape The end of the cable should be connected to the door sensor socket in the AC100 controller or the AB101 set The door sensor cable can be shortened to the required length and reterminated with an RJ45 plug or its spare rolled up and fixed in such a way that it does not i...

Страница 35: ...us interface 35 5 7 Installation of cabinet door wiring Connect the reader to the controller with the AW111 cable On the door hide the cable in dedicated cable paths Fix the cables in the cabinet using cable ties Leave a spare cord between the door and the cabinet frame to allow the door to be opened ...

Страница 36: ...o the required length and reterminated with an RJ45 plug or its spare rolled up and fixed in such a way that it does not interfere with other devices in the cabinet Connect the AL200 handle to the reader using the AW212 cable or the AW112 cable for the AL300 handle Connect the cables to the reader and arrange them carefully Secure them with electrical tape ...

Страница 37: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 37 Screw on the reader connector cover ...

Страница 38: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 38 5 8 Diagram of functional circuits for operating the cabinet door ...

Страница 39: ...a dedicated place on the side wall of the cold hot aisle containment If the containment wall does not have dedicated holes make the mounting holes as shown in the picture on the right Make sure that the reader installation location will not interfere with the sliding doors Connect the reader to the AC100 controller or the AB101 set located in the nearest cabinet Use the AW111 cable The cable must ...

Страница 40: ...able see 3 6 3 AW113 cable to the sliding door reader and then route it without cutting it to the emergency button exit button and sliding door controller Cut and terminate only the wires of the cables that need to be connected to the device Place and clamp the ferules on the ends of the cables before connecting them Make connections as shown in the diagram 6 6 Connection diagram of sliding kiosk ...

Страница 41: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 41 6 6 Connection diagram of sliding kiosk door control devices ...

Страница 42: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 42 6 7 Diagram of functional circuits for operating the sliding door ...

Страница 43: ...ce New 4 Select the device model MC16 v1 x firmware version communication channel Ethernet 5 Enter the IP address of the MC16 factory default IP address 192 168 0 213 6 Enter the communication key factory default password is 1234 In controllers with version older than 1 4 the factory password is empty 7 Click Connect the program will connect to the controller and automatically go to the Configurat...

Страница 44: ...access the controller 1 Select Tools Set communication key from menu 2 Enter key You can use only hex signs 0 9 A B C D E F 3 Write the key down as it will be needed at high level configuration of the system 4 Click Set key button 5 Click Close button Send settings to the device click Send to Device button Ending the controller low level configuration 1 In Roger VDM menu select Device Disconnect 2...

Страница 45: ...tor 2 Connect the RJ45 plug of the AW111 cable to the RUD 1 interface as shown in the figure below Putting the reader into the service mode AR121 and AR122 readers UNIQUE readers do not require any additional steps In AR131 and AR132 readers Mifare readers you should 1 Remove the MEM jumper on the reader 2 Restart the reader turn off and turn on the power or short RST jumper for a moment orange LE...

Страница 46: ...n tab Firmware update 1 Make sure that the device has the newest firmware The version currently installed on the device is displayed in the bottom bar of the application window The latest versions of firmware can be downloaded from the website www roger pl 2 To run the firmware update disconnect Device Disconnect and then select Tools Update Firmware from the menu For the UNIQUE readers AR121 and ...

Страница 47: ...s 5 8 Diagram of functional circuits for operating the cabinet door 6 7 Diagram of functional circuits for operating the sliding door AR121 AR131 for cabinet door Input IN1 NC Input IN2 NC Input IN3 NO AR122 AR132 for cold hot aisle containment sliding door Input IN1 NC Input IN2 NC Input IN3 NO Describe the reader s inputs and outputs These descriptions will be visible in the high level VISO ST s...

Страница 48: ...FTWARE The Roger SVC software must be installed for the system to function properly Once installed the software runs as Windows service The software is responsible for communication with system controllers and writing information to the database The service package must be installed only on one computer e g on a server 8 1 SVC software installation Download from http www roger pl en and run the fi...

Страница 49: ...tion manual of the access control system with RS485 bus interface 49 8 2 SVC software configuration Open the service management application from the taskbar shortcut Click on Database connection Click on Configure connection Click on Select database ...

Страница 50: ... control system with RS485 bus interface 50 Select the file with the database created in the VISO software and confirm See section 9 2 Database configuration Enter the database password if it was created and click OK Go back to the main window Click on Communication service ...

Страница 51: ...www bkte pl BKT ACBS installation and configuration manual of the access control system with RS485 bus interface 51 Click Start Go back to the main window Services have been configured Close the window ...

Страница 52: ...n Cabinet door configuration Cold hot aisle containment sliding door configuration Open door signalling configuration etc Adding system users 9 1 VISO ST software installation Download from www roger pl en and run the VISOSetup exe file Then follow the windows that appear After installation the first time you run the program you must configure the database access See section 9 2 Database configura...

Страница 53: ...database file Enter the name of the database file in the Database field Optionally enter a password to protect access to the database Confirm by clicking OK After configuration the software will restart using the created database In the newly created database the administrator s access password is empty 9 3 Controller configuration The system configuration should be started by adding a new control...

Страница 54: ...assword that was created during the low level configuration of the controller See section 7 1 Controller low level configuration Click Next Settings are being saved to the database Then on the confirmation window click OK The controller will now search for readers that have been connected to the bus Select Run Device Discovery Process Click Run The controller and all the readers connected to it sh...

Страница 55: ...shed In the tree view expand System Networks All system readers connected to the controller should appear in the system tree view In the tree view expand System Networks DataCenter C1 Hardware Resources The above configuration should be sent to the controller See chapter 9 4 Data synchronising 9 4 Data synchronising Data synchronisation is an uploading to the system controllers the configuration c...

Страница 56: ...o participate in the synchronisation Then click Start Correctly completed process of data synchronisation with controllers is indicated by a green field next to each of them Click Close 9 5 Cabinet door configuration To start the door configuration Choose Wizards Add Access Door In the pop up windows Choose Read in only the door with card reader on one side Click Next ...

Страница 57: ...lock control relay For this purpose it is necessary to know which address has the reader installed on the configured cabinet door In this example only one reader with address 100 is displayed Drop down the Read in Terminal list and select READER from the appropriate card reader Drop down the Door Lock Output list and select REL1 from the appropriate card reader Drop down the Door Contact Input lis...

Страница 58: ...s is the optimal unlocking time for cabinet electronic handles Click Next Create a new access authorization for this door This authorization you will later be able to assign to a user group so they could open that door The program will suggest a name C1_Cab 01 front_IN_AUTH Choose Create new Authorisation Click Next System saves the settings to the database ...

Страница 59: ...door sensor has been assigned to the door It is necessary to assign the IN3 input sensor of the handle In this way the system will recognize the door status as open when either door or handle is open In the tree view right click on System Networks DataCenter C1 Access Doors and select Open Click on the door which just has been added to the system C1_Cab 01 front Choose Inputs tab Click Add In the ...

Страница 60: ... swinghandle sensor is connected Click on the drop down list in the field Object Name Select IN3 input of the card reader MCT12x IO which belongs to currently configured door The program will propose a name for the selected object Confirm the suggestion by clicking Yes Confirm the input line by clicking OK In the Function field select the function 130 Door Contact Click OK ...

Страница 61: ...tem tree view In the tree view expand System Networks DataCenter C1 Access Doors The above configuration should be sent to the controller See chapter 9 4 Data synchronising 9 6 Cold hot aisle containment sliding door configuration To start the door configuration Choose Wizards Add Access Door In the pop up windows Choose Read in only the door with card reader on one side Click Next ...

Страница 62: ... and exit button For this purpose it is necessary to know which address has the reader installed on the configured sliding door In this example only one reader with address 100 is displayed Drop down the Read in Terminal list and select READER from the appropriate card reader Drop down the Door Lock Output list and select REL1 lock from the appropriate card reader Drop down the Door Contact Input ...

Страница 63: ... list and select IN3 exit button from the appropriate card reader Click Next Create a new authorisation to access this door This authorisation will then be assigned to the user so that he can open the door The program will propose the name C1_Aisle 01 front_IN_AUTH Choose Create new Authorisation Click Next System savs the settings to the database ...

Страница 64: ...ataCenter C1 Access Doors 9 7 Permanent opening of the cold hot aisle containment sliding door Sometimes while working in the server room it is necessary to block the entrance door to the cold hot aisle containment in a permanently open position Pressing the F1 button on the door reader keypad and then applying the authorized user card will open the door and lock it in the open position To close t...

Страница 65: ...elect Function Keys tab Click Add In the pop up window Click on in Function Key field In the next window that opens select the keypad of the cold hot aisle containment front door reader Drop down the Object Name list and select KEYPAD of the reader which controls aisle door The program will propose a name for the selected object Confirm the suggestion by clicking Yes ...

Страница 66: ...old hot aisle containment door Click OK Select Function 136 Set Alternately Normal Unlock Door Mode Tick User Authentication required option Click OK The use of the F1 button has been The above configuration should be sent to the controller See chapter 9 4 Data synchronising After synchronization the controller will restart and it will be possible to use this functionality ...

Страница 67: ...users must have permission to open this door If more than two users have permission to open that door then any two of them can do this To start configuration In the tree view click right on System Networks DataCenter C1 Access Points and select Open Select required access point card reader which is to be configured as a two user entry Select Main tab Select Edit In the newly opened window Select A...

Страница 68: ...point reader C1_Cab 01 front has been configured as a two user entry The above configuration should be sent to the controller See chapter 9 4 Data synchronising 9 9 Open door signalling with LED The system enables configuration of signalling LEDs located on the AC100 controller and the AB101 secondary set enclosures These LEDs are connected to reader outputs LED1 output OUT1 IO1 of front door card...

Страница 69: ...be used to check the door status IN1 door sensor IN3 door handle sensor Since these lines have already been assigned in the configuration of the door in order to be able to use them again you need to change their properties to the multifunctional lines For this purpose In the system tree right click on System Networks DataCenter configurable name C1 configurable controller name Inputs and select O...

Страница 70: ...function option Click OK Now you can use again the IN3 door handle sensor input for configuration The configuration process of the automation node that will be responsible for the LED1 control In the system tree right click on System Networks DataCenter configurable name C1 configurable controller name Automation Nodes and select Open A new automation node should be created that will be responsibl...

Страница 71: ...ate to OFF Untick Register events It is not necessary to log LED events Click OK It is now necessary to add input lines that will affect the state of the LED1 Select just created automation node Cab 01 LED12 Click on Inputs tab Click Add In the pop up window Drop down the Input list and select available IN1 line door sensor Drop down the Function list and select 166 Set Node ON Toggle Click OK ...

Страница 72: ...3 input of door handle sensor In the pop up window Drop down the Input list and select available IN3 line door handle sensor Drop down the Function list and select 166 Set Node ON Toggle Click OK It is now necessary to add the output line to which the LED1 is connected Click on Outputs tab Click Add In the pop up window Click on in Output field ...

Страница 73: ...reader see 5 8 Diagram of functional circuits for operating the cabinet door Drop down Object Name list Select OUT1 IO1 of the front door reader The program will propose a name for the selected object Confirm the suggestion by clicking Yes Confirm the input line by clicking OK In the field Function select 021 Node Status Select Triggering Method Set output ON for unlimited time Select Modulation T...

Страница 74: ... should light up when the door or handle is open Similarly configure the LED2 which will signal the opening of the rear door of the cabinet 9 10 Tamper signalling Opening the controller box the slave set box or the reader casing can be monitored in the system as a sabotage In order for the sabotage condition to be saved to the database and at the same time to be signalled by sound and led on the r...

Страница 75: ...on manual of the access control system with RS485 bus interface 75 Enter the automation node name eg C1_Cab 01 tamper Click OK Make sure the proper automation node is selected Click on Inputs tab Click Add In the pop up window Click on in Input field ...

Страница 76: ...d window select the IN2 tamper line of the card reader which is installed on the door of the configured cabinet Drop down Object Name list and select input IN2 of the card reader of the configured door The program will propose a name for the selected object Confirm the suggestion by clicking Yes Confirm the input line by clicking OK ...

Страница 77: ...of the cabinet other door reader if it exists Click Add to add all tamper lines of currently configured cabinet This configuration is sufficient to log readers tampering in events You just need to sync data see chapter 9 4 Data synchronising Additional tamper acoustic signaling To additionally signal the tamper status audibly appropriate output line should be added Click Outputs tab Click Add In t...

Страница 78: ...ured cabinet Drop down the Object Name list and select BUZZER output of the cabinet front door reader The program will propose a name for the selected object Confirm the suggestion by clicking Yes Confirm the input line by clicking OK In the field Function select 021 Automation Node Status Select Triggering Method Set output ON for unlimited time Select Modulation Type One Short Pulse repeated eve...

Страница 79: ...ate the tamper state by the LED on the reader add the appropriate output lines Click Add In the pop up window Click on in Output field In the next opened window select the LED of the cabinet door reader Drop down the Object Name list and select LED_SYSTEM output of the reader The program will propose a name for the selected object Confirm the suggestion by clicking Yes ...

Страница 80: ...ime Select Modulation Type One Short Pulse repeated every 1s Click OK The cabinet tamper signalling has been configured The created tamper automation node should appear in the system tree The above configuration should be sent to the controller See chapter 9 4 Data synchronising After synchronization if the controller box is opened the reader on the front door will flash a yellow LED and buzz the ...

Страница 81: ...nt can be monitored in the system In order to save status of this button into the database and simultaneously indicate the use of it by sound and LED on the reader the automation node has to be used In the system tree right click on System Networks DataCenter configurable name C1 configurable controller name Automation Nodes and select Open Click Add Enter the name of automation node eg C1_Aisle f...

Страница 82: ...the next opened window select the IN2 line of the reader which is mounted next to the cold hot aisle containment sliding door In AR122 readers this line is also used to control the reader s tamper To add IN2 line Drop down Object Name list and select input IN2 of the reader which controls aisle door The program will propose a name for the selected object Confirm the suggestion by clicking Yes ...

Страница 83: ...ld select the function 166 Automation Node On Toggle Click OK This configuration is sufficient to log the use of the emergency button The data must be only synchronize see chapter 9 4 Data synchronising Additional acoustic signaling In order to indicate the emergency button use with buzzer and or LED the appropriate output lines should be added Click Outputs tab Click Add ...

Страница 84: ... Click on in Output field In the next opened window select the buzzer BUZZER of the aisle sliding door reader Drop down the Object Name list and select BUZZER output of the reader which controls aisle door The program will propose a name for the selected object Confirm the suggestion by clicking Yes Confirm the input line by clicking OK ...

Страница 85: ...ficient to log the use of the emergency button and to indicate with buzzer The data must be only synchronize see chapter 9 4 Data synchronising Additional LED signaling To additionally indicate the evacuation state by the LED on the reader add the appropriate output lines Click Add In the pop up window Click on in Output field In the next opened window select the LED of the cold hot aisle containm...

Страница 86: ...me Select Modulation Type Two Short Pulse repeated every 1s Click OK The indication of the use of the emergency button has been configured The created automation node that supports this feature should appear in the system tree The above configuration should be sent to the controller See chapter 9 4 Data synchronising After synchronization the controller will restart and if the emergency exit butto...

Страница 87: ...ed group of doors Any user who belongs to such group will have the rights of this group In the system tree view click with the right button on Access Users and select Add Group Enter the name of user group Click OK You must assign authorisations that were created during the door configuration to just created group In the system tree view click with the right button on just created user group and s...

Страница 88: ... A group of users with permissions to open dedicated doors has been created The above configuration should be sent to the controller See chapter 9 4 Data synchronising 9 13 Adding user to group In order to add a new user Choose Wizards Add person Online In the opened window Enter user name Select the user group to which user should belong in this way the user will be given the rights to open the d...

Страница 89: ...Credential Click Next The credential name can be edited here Click Next In the next two windows it is possible to assign permissions directly to the user Since the user being added at this moment has already been granted permissions from the user group to which he belongs these two configuration windows should be left out without making any changes Click Next Once again click Next ...

Страница 90: ... the entire system Select the type eg card or PIN Enter the PIN or card number or click Read from Reader If you have chosen to read from the reader a new window will appear Choose the type of reader USB reader connected to a computer or system reader any reader so far configured in the system If you have chosen a system reader click on the reader you want to use to read the card Present the card t...

Страница 91: ...ion manual of the access control system with RS485 bus interface 91 Click OK Click Next Data have been saved to database Click OK Upload the configuration to the device that is synchronise the controller Click Send After synchronisation click Finish ...

Страница 92: ...p Applying just a configured card to the reader should open the door 10 DOCUMENT REVISIONS Version Changes Date 1 Initial version June 2018 2 Added communication key setting in the controller low level configuration July 2018 3 Added comparison to the BKT ACWS system Small updates have been made November 2018 4 Added two user entry configuration February 2019 5 Updated with new AC100 controller an...

Отзывы: