60
Model
FX-i11
Inside sound power level
58 dB(A)
Refrigerant
R410A
GWP Refrigerant
2088 KgCO
2
ep.
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global war-
ming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [2088].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times higher
than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and
always ask a professional.
EER
rated
3,2
Cooling energy efficency class
A+
Indicative hourly electricity consumption in cooling
Q
DD
0,7
kWh/60min
Energy consumption “0,7” kWh per 60 minutes, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located
Cooling capacity P
rated
2,3 kW
COP
rated
3,3
Heating energy efficency class
A
Indicative hourly electricity consumption in heating
Q
DD
0,7
kWh/60min
Energy consumption “0,7” kWh per 60 minutes, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
Capacità di riscaldamento P
nomonale
Heating capacity P
rated
2,3 kW
PRODUCT FICHE