background image

SS-OM-043.02 

 

Revised  5/20/2013 

 

BKI LIMITED WARRANTY 

2812 Grandview Drive • Simpsonville, SC 29680 • USA 

(864) 963-3471 • Toll Free: (800) 927-6887 • Fax: (864) 963-5316 

 

WHAT IS COVERED 

This warranty covers defects in material and workmanship under normal use, and applies only to the 
original  purchaser providing that:

 

 The equipment has not been accidentally or intentionally damaged, altered or misused; 

 

The  equipment  is  properly  installed,  adjusted,  operated  and  maintained  in  accordance  with

 

national 

and  local  codes,  and  in  accordance  with  the  installation  and  operating  instructions  provided  with  this 
product. 

 

The serial number rating plate affixed to the equipment has not been defaced or removed. 

WHO IS COVERED 

 

This warranty is extended to the original purchaser and applies only to equipment 

purchased for use  in the U.S.A.

 

COVERAGE PERIOD

 

  

Warranty claims must be received in writing by BKI within one (1) year from date of 

installation or within one (1) year and three (3) months from data of shipment from the factory, 
whichever comes first. 

 

COB Models:  One (1) Year limited parts and labor. 

 

COM Models:  Two (2) Year limited parts and labor.  COM convection ovens also have a two (2) year 

door warranty.

 

 

Warranty period begins the date of dealer invoice to customer or ninety (90) days after 

shipment date from BKI, whichever comes first.

 

WARRANTY COVERAGE 

This warranty covers on-site labor, parts and reasonable travel time and travel expenses of the 
authorized service representative up to (100) miles round trip and (2) hours travel time and  
performed during regular, weekday business hours.

 

EXCEPTIONS 

 

Any exceptions must be pre-approved in advance and in writing by BKI.   

EXCLUSIONS 

 

 

Negligence or acts of God,

  

 

Thermostat calibrations after (30) days from equipment installation date, 

 

Air and gas adjustments, 

 

Light bulbs, 

 

Glass doors and door adjustments,  

 

Fuses, 

 

Adjustments to burner flames and cleaning of pilot burners, 

 

Tightening of screws or fasteners, 

 

Failures caused by erratic voltages or gas suppliers, 

 

Unauthorized repair by anyone other than a BKI Factory Authorized Service Center, 

 

Damage in shipment, 

 

Alteration, misuse or improper installation, 

 

Thermostats and safety valves with broken capillary tubes, 

 

Freight – other than normal UPS charges, 

 

Ordinary wear and tear, 

 

Failure to follow installation and/or operating instructions, 

 

Events beyond control of the company. 

INSTALLATION 

 

Leveling, as well as proper installation and check out of all new equipment - per appropriate 
installation and use materials – is the responsibility of the dealer or installer, not the manufacturer. 

REPLACEMENT PARTS 

BKI genuine Factory OEM parts receive a (90) day materials warranty effective from the date of 
installation by a BKI Factory Authorized Service Center. 

 
Warranty is in lieu of all other warranties, expressed or implied, and all other obligations or liabilities on the manufacturer’s part.  
BKI shall in no event be liable for any special, indirect or consequential damages, or in any event for damages in excess of the 
purchase price of the unit.  The repair or  replacement of proven defective parts shall constitute a fulfillment of all obligations 
under the terms  of this warranty.

 

 
 
 

Содержание MHB

Страница 1: ...SS OM 043 02 Revised 5 20 2013 Mobile Hot Bar MODEL MHB Installation Operation Manual ...

Страница 2: ...und trip and 2 hours travel time and performed during regular weekday business hours EXCEPTIONS Any exceptions must be pre approved in advance and in writing by BKI EXCLUSIONS អ Negligence or acts of God អ Thermostat calibrations after 30 days from equipment installation date អ Air and gas adjustments អ Light bulbs អ Glass doors and door adjustments អ Fuses អ Adjustments to burner flames and clean...

Страница 3: ...rols and Indicators 5 Hardware Controls 5 Preheating 6 Temperature Adjustment 6 Operational Guidelines 6 Unit Shutdown 6 Installation 7 Unpacking and Handling 7 Location 7 Wiring Connection And Grounding 7 General Guidelines 7 Mechanical Specifications 8 Maintenance 9 Scheduled Maintenance 9 Cleaning 9 Troubleshooting 11 Accessories 12 Wiring Diagrams 13 MHB 3 13 MHB 4 14 MHB 5 15 Notes 16 ...

Страница 4: ...ial hazards exist and special precautions should be taken Know and understand the meaning of these instructions signs and messages Damage to the equipment death or serious injury to you or other persons may result if these messages are not followed This message indicates an imminently hazardous situation which if not avoided will result in death or serious injury This message indicates a potential...

Страница 5: ...ipment Your customer should keep it near for easy access If your customer needs a replacement operators manual contact BKI Technical Services Department 2812 Grandview Dr Simpsonville S C 29680 Or call toll free 1 800 927 6887 Outside the U S call 864 963 3471 Safety Labels Must be Clean and in Good Condition Make sure all safety labels are in place clean and in good condition Replace any damaged ...

Страница 6: ...oduction 4 1 2 1 0 3 4 5 9 6 7 8 1 2 1 0 3 4 5 9 6 7 8 1 2 1 0 3 4 5 9 6 7 8 1 2 1 0 3 4 5 9 6 7 8 1 2 1 0 3 4 5 9 6 7 8 UPPER CANOPY POWER 1 2 3 4 WELL 4 WELL 3 WELL 2 WELL 1 1 2 1 0 3 4 5 9 6 7 8 WELL 5 5 Safety Labels ...

Страница 7: ... 6 7 8 UPPER CANOPY POWER 1 2 3 4 WELL 4 WELL 3 WELL 2 WELL 1 1 2 1 0 3 4 5 9 6 7 8 WELL 5 5 2 1 3 Hardware Controls Item Description Function 1 Main Power Switch Turns power On or Off to the entire unit When placed in the on position the well and overhead heaters are powered and the lights illuminate When placed in the off position power is removed from the entire unit 2 Individual Well Thermosta...

Страница 8: ...he proper internal temperature of the food product The thermostats should be set to the lowest possible setting that will maintain the proper product temperature Operational Guidelines Foods should be a minimum of 175 F 80 C before being placed in the unit Keep food thermometer on hand Check the food temperatures every 30 minutes Rotate the food products Foods loaded in first should be served firs...

Страница 9: ... of the shipping pallet Make certain there are no separately packed accessories before discarding packaging Location The unit must be located on a level surface After moving the unit be sure to lock all 4 casters on the unit Wiring Connection and Grounding Electrocution equipment failure or property damage could result if an unlicensed electrician performs the electrical installation Ensure that a...

Страница 10: ... 8 327 0 OPTIONAL ANGLED WELL RISER TOP CORD ENTRY 3 4 KNOCK OUT BOTTOM CORD ENTRY 3 4 KNOCK OUT MODEL WELLS DIM A MHB 3 3 43 1092 MHB 4 4 56 1 2 1435 MHB 5 5 70 1778 208V 220V 240V MODEL kW Amps kW Amps kW Amps MHB 3 3 3 10 7 15 9 3 2 10 0 14 7 3 8 10 9 16 0 MHB 4 4 4 12 5 21 1 4 3 11 5 19 5 5 1 12 5 21 2 MHB 5 6 2 18 7 29 9 6 0 16 2 27 4 7 2 17 7 29 8 ALL MODELS ARE 3 or 1 Ph AMPS SHOWN ARE 3 Ph...

Страница 11: ...the cabinet finish Use only a mild soap and water solution Never steam clean or get excess water in the interior of the cabinet as this can damage unit This appliance is not intended to be cleaned with a water jet Never use cleaners containing ammonia Windex 409 etc on the clear plastic parts of the unit Ammonia will damage these parts Never use a dry cloth or your hands to remove dirt and dust fr...

Страница 12: ...Hot Bar Maintenance 10 STEP 1 LIFT UP BOTTOM OF BACK PANEL STEP 2 PULL BOTTOM OF BACK PANEL OUT CLEAR OF BACK OF UNIT STEP 3 LOWER BACK PANEL OUT OF UPPER CHANNEL REMOVE FROM UNIT MHB SOLID BACK PANEL REMOVAL ...

Страница 13: ... to the Preheating section of this manual Product is below temperature when loaded into merchandiser Check product temperature before loading the merchandiser Well or Upper Canopy thermostat setting too low Refer to Temperature Adjustment section of this manual One or more heating elements not operating properly Contact authorized BKI service company Light Bulb s Do Not Illuminate when Power is tu...

Страница 14: ...led Well Riser WB64406500 Accommodates 2 1 2 or 4 full size steam table pans End Shelves Consult Factory Available on either or both ends of the hot bar Designed to meet your specific merchandising requirements End Shelf with Removable Tray shown ...

Страница 15: ...N 3 POLE END PLATE TERMINAL SEC GROUND TERM SEC 3 POLE END STOP TERMINAL SEC TERM BLOCK 2 POLE CERAMIC COMPONENT LEGEND KEY Part No DESCRIPTION SW1 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe T1 P1 SW2 R1 BLUE BLUE YEL YEL RED RED BLUE YEL YEL RED 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe H1 H2 B1 TB3 L1 TB1 TB2 R1 R1 POWER B1 T...

Страница 16: ... TERMINAL SEC GROUND TERM SEC 3 POLE END STOP TERMINAL SEC TERM BLOCK 2 POLE CERAMIC COMPONENT LEGEND KEY Part No DESCRIPTION SW1 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe T1 P1 SW2 R1 BLUE BLUE YEL YEL RED RED BLUE YEL YEL RED 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe H1 H2 ...

Страница 17: ...SEC 3 POLE END STOP TERMINAL SEC TERM BLOCK 2 POLE CERAMIC COMPONENT LEGEND KEY Part No DESCRIPTION SW1 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe T1 P1 SW2 R1 BLUE BLUE YEL YEL RED RED BLUE YEL YEL RED 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux 1 Aux 3 Aux 2 Probe 120 100 COM 240 Relay Relay Aux ...

Страница 18: ...SS OM 043 02 Revised 5 20 2013 Notes 2812 Grandview Dr Simpsonville S C 29680 USA http www bkideas com Made and printed in the U S A ...

Отзывы: