SV9401/SV9402/SV9403, SV9501/SV9502/SV9503, SV9601/SV9602 SMARTVALVE™ SYSTEM CONTROLS
69-1004—2
4
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death or property
damage.
Follow these warnings exactly:
1. Disconnect power supply before wiring to
prevent electrical shock or equipment damage.
2. To avoid dangerous accumulation of fuel gas,
turn off gas supply at the appliance service
valve before starting installation, and perform
Gas Leak Test after completion of installation.
3. Do not bend pilot tubing at ignition system
control or pilot burner after compression fitting
is tightened, or gas leakage at the connection
can result.
4. Always install a sediment trap in gas supply
line to prevent contamination of ignition system
control.
WARNING
Electrical Shock or Equipment Damage
Hazard.
Can cause severe injury, death or equipment
damage.
1. Never apply a jumper across or short the
thermostat, 24V hot or 24V common terminal
in the SV9401/SV9402/SV9403, SV9501/
SV9502/SV9503, or SV9601/SV9602 wiring
harness. This can burn out the heat anticipator
in the thermostat or damage the system
transformer.
2. Never short the electronic fan timer (EFT)
output. This can damage the EFT drive
circuitry.
IMPORTANT
These ignition system controls are shipped with
protective seals over the inlet and outlet
tappings. Do not remove the seals until ready to
connect the piping.
Follow the appliance manufacturer instructions if
available; otherwise, use these instructions as a guide.
Converting Ignition System Control from
Natural Gas to LP Gas Application (or LP
Gas to Natural Gas Application)
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death or property
damage.
1. Do NOT attempt to convert step-opening
models (SV9401P/SV9402P/SV9403P,
SV9501P/SV9502P/SV9503P, or SV9601P/
SV9602P).
2. Always change the main and pilot burner
orifices when converting from natural to LP gas
or from LP to natural gas. Follow appliance
manufacturer specifications and instructions to
assure proper appliance conversion.
3. Ignition system controls are factory-set for
natural (and manufactured) or LP gas. Do not
attempt to use an ignition system control set
for natural (manufactured) gas on LP gas, or
an ignition system control set for LP gas on
natural (manufactured) gas.
Convertible (Natural/LP) Regulator for
Mobile Home Applications
Ignition system controls with suffix letter R are
convertible pressure regulator models. They can be
converted from natural gas to LP or from LP to natural
gas without a conversion kit.
Before converting the ignition control from one gas to
another, check the ignition control label and the
appliance manufacturer rating plate to determine if the
factory-set pressure regulator setting meets the
appliance manifold requirements after conversion.
NOTE: Convertible pressure regulator models (suffix
letter R) do not have field-adjustable regulators.
If the factory pressure regulator setting meets the
appliance manifold requirement, convert the ignition
control using the following procedure:
1.
Remove the pressure regulator cap. See Fig.
2.
Turn over the cap so the letters facing up are for
the gas type the appliance uses NAT for natural
gas and LP for LP gas.
3.
Replace the cap and tighten firmly.
Install Adapters on Control
IMPORTANT
3/4 in. inlets and outlets do not accommodate
flange adapters.
If adapters are being installed on the control, mount them
as follows:
Flanges
1.
1.Choose the appropriate flange for your
application as listed in Table 5.
2.
2.Remove the seal over the ignition system control
inlet or outlet.
69-1004-2.fm Page 4 Wednesday, November 5, 2003 10:49 AM
Содержание LGF
Страница 10: ...Gas Pressure Fryer Introduction 8 Safety Labels ...
Страница 11: ...Gas Pressure Fryer Introduction 9 ...
Страница 38: ...Gas Pressure Fryer Notes 36 Notes ...
Страница 39: ...Gas Pressure Fryer Appendix A 37 Appendix A Gas Control Valve Instructions ...
Страница 56: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0101 0205 ...