HSS Hot Food Merchandiser
Installation
CS-TM-003.01
Revised 10/01/18
9
Supply Cable Connection
•
It is recommended that the power supply cable shall be an oil resistance sheathed flexible cable to BS 6007 (code
designation HO7 RN-F).
•
It is required that the power supply cable connection to the appliance terminal block, the earth conductor is to be
made at least 50mm longer than the length of the live (L) and neutral (N) conductors so that if the supply cable is
strained the earth conductor is the last to become disconnected.
•
To gain access to the control panel and mains block connection, remove the 4-side panel securing screws on the
drive side of the oven.
•
The mains block is sited toward the bottom right hand side of the control box. Cable entry is provided through the
base of the oven.
•
Refer to the mains wiring diagram for correct connection.