Electric Autolift Fryer
Operation
15
BLF-F Operation
System Programming
The controller must be configured with its basic operating parameters before using. These parameters are
the operational mode (cooking or frying), the temperature units, and the control hysteresis. You may also
display the current temperature and test the output relays in this configuration mode. To access these
parameters, press and hold the
[5
]
button, apply the AC operating power by touching the
FRY
button on
the
FILTER/OFF/FRY
switch, and then release the
[5
]
button.
Operating Mode
– The controller now displays its basic operating mode as shown in the table below. Use
the
[2
]
and
[5
]
buttons to change to the desired operating mode. Press the
[3SET]
button to save and
advance to the next parameter which is the temperature units
.
LED Display
Operating Mode
OP:CF
Cooking controller with fan output on K2
(default)
OP:CO
Cooking controller with no fan output
OP:FL
Frying controller with Lift output on K2, 1 sec @ end
OP:Fr
Frying controller with no lift output
OP:FP
Frying controller for pressure, K2 on for fry cycle
Temperature Units
– The unit can display temperature in either degrees Fahrenheit or Centigrade. Use the
[2
]
and
[5
]
buttons to change to the desired temperature units,
[3SET]
saves and advances to the
next parameter which is the temperature control hysteresis.
LED Display
Temperature Units
Un:°F
Temperature in degrees Fahrenheit
(default)
Un:°C
Temperature in degrees Centigrade
Melt Cycle Parameters
– The control provides a built in melt cycle for fryers, the configuration items are the
heat on time, the heat off time, and the temperature where the controller transitions to standard
temperature control. Use the
[2
]
and
[5
]
buttons to change to the desired values,
[3SET]
saves and
advances to each item and then finally to the temperature control hysteresis.
LED Display
Parameter
Setting
On:08
Heat On Time
Set between 1 and 60 sec
(default = 8 sec)
OF:15
Heat Off Time
Set between 1 and 60 sec
(default = 15 sec)
225°
Transition Temp Set between 150° and 275°
(default = 225°)
Control Hysteresis
– This value is the number of degrees Fahrenheit above and below the setpoint at
which the temperature control relay switches. The output relay will be on until the current temperature
reaches the current setpoint
plus
the control hysteresis value, and the relay will be off until the temperature
drops down to the setpoint
minus
the control hysteresis value. This value can be set anywhere from 3°F to
20°F and is set to the default value of 5°F during the factory testing. Use the
[2
]
and
[5
]
buttons to
change to the desired value,
[3SET]
advances to the next parameter which is the temperature control
hysteresis.
LED Display
Hysteresis Value
Hy:XX
XX = the value in °F from 03
– 20
(default = 5)