BK Radio GPH-CMD Скачать руководство пользователя страница 4

   

32                                                                                            BK Radio

 

NOTES: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 GPH-CMD Owner’s Manual                                                                5                                                           

RF ENERGY EXPOSURE AWARENESS AND 

CONTROL INFORMATION, AND OPERATIONAL 

INSTRUCTIONS FOR FCC  OCCUPATIONAL USE 

REQUIREMENTS 

BEFORE USING YOUR PORTABLE 2-WAY RADIO, 

READ THIS IMPORTANT RF ENERGY AWARENESS AND 

CONTROL INFORMATION AND 

OPERATIONAL INSTRUCTIONS TO ENSURE COMPLIANCE WITH 

THE FCC’S RF EXPOSURE GUIDELINES. 

NOTICE:  This radio is intended for use in occupational/controlled 
conditions, where users have full knowledge of their exposure 
and can exercise control over their exposure to meet FCC limits.  
This radio device is NOT authorized for general population, 
consumer, or any other use. 

This 2-way radio uses electromagnetic energy in the radio frequency 
(RF) spectrum to provide communications between two or more users 
over a distance.  It uses radio frequency (RF) energy or radio waves to 
send and receive calls.  RF energy is one form of electromagnetic 
energy; other forms include electric power, radar, sunlight and  x-rays. 
RF energy, however, should not be confused with these other forms of 
electromagnetic energy, which  when used improperly  can cause 
biological damage.  Very high levels of x-rays, for example, can 
damage tissues and genetic material. The energy levels associated 
with radio waves from portable 2-way radios, when properly used, are 
not great enough to cause biological damage. 

Experts in science, engineering, medicine, health and industry work 
with organizations to develop standards for exposure to RF energy. 
These standards provide recommended levels of  RF exposure for both 
workers and the general public. These  recommended RF exposure 
levels include substantial margins of protection. All 2-way radios 
marketed in North America are designed, manufactured and tested to 
ensure they meet government  established RF exposure levels. In 
addition, manufacturers also recommend specific operating 
instructions to users of 2-way radios. 

These instructions are important because they inform users about RF 
energy exposure and provide simple procedures on how to control it

.

  

Please refer to the following WEBSITES for more information on what 
RF energy exposure is and how to control your exposure to assure 
compliance with established RF exposure limits. 

http://www.fcc.gov/oet/rfsafety/rf-faqs.html

  

http://www.osha.gov/SLTC/radiofrequencyradiation/index.html

 

 

Содержание GPH-CMD

Страница 1: ...Technology Drive West Melbourne FL 32904 Telephone 321 984 1414 FAX 321 984 0434 www relm com Copyright 2005 RELM Wireless Corporation All rights reserved P N 7001 30969 300 03 02 GPH CMD PORTABLE RADIO OWNERS MANUAL ...

Страница 2: ...mation 5 Radio Controls 8 Basic Operation 9 Code Guard Operation 10 Command Group 11 Channel Groups 13 Programmable Top Switches Function Menu 13 Scan Operation 14 Priority Scan 17 User Transmit Code Guard 21 Other Operational Features 22 Alphanumeric Display 25 Cloning Procedure 26 Battery Installation And Removal 29 Definitions And Acronyms 31 Service Inside Back Cover ...

Страница 3: ...Your radio must be properly licensed by the Federal Communications Commission prior to use Your BK Radio dealer can assist you in meeting these requirements Your dealer will program each radio with your authorized frequencies signaling codes etc and will be there to meet your communications needs as your system expands SAFETY PRECAUTIONS Do not operate the transmitter in close proximity to blastin...

Страница 4: ...nergy which when used improperly can cause biological damage Very high levels of x rays for example can damage tissues and genetic m aterial The energy levels associated with radio waves from portable 2 way radios when properly used are not great enough to cause biological damage Experts in science engineering medicine health and industry work with organizations to d evelop standards for exposure ...

Страница 5: ... up to 50 talk Your BK Radio 2 way radio complies with the following RF energy exposure standards and guidelines United States Federal Communications Commission Code of Federal Regulations 47 CFR 1 1307 1 1310 2 1091 and 2 1093 American National Standards Institute ANSI Institute of Electrical and Electronic Engineers IEEE C95 1 1992 Institute of Electrical and Electronic Engineers IEEE C95 1 1999...

Страница 6: ...ecause this radio generates measurable RF energy exposure only when transmitting in terms of measuring for standards compliance Hold the radio in a vertical position in front of face with the microphone and the other parts of the radio including the antenna at least one inch 2 5 cm away from the nose Keeping the radio at the proper distance is important because RF exposures decrease with distance ...

Страница 7: ...tiple beeps will follow Failure of downloading can be due to Improper connection Failure to turn on the clone Setting the clone in Programming Mode Target radio s group locked by PC Programming NOTE To stop the FAILURE Mode press CLR turn off both radios and try again starting with Step 1 on the previous page BATTERY INSTALLATION AND REMOVAL BK Radio battery packs are available in a variety of siz...

Страница 8: ...LR key Navigate to a CH prompt then press and hold the key to get the GRP prompt CLONING Group 01 PROG GPHcmD Group 01 PROG GPH Group 01 Press and Hold Key to Change Target PROG GPHcmD Cmnd group PROG GPHcmD pick list Press and Hold Key to Change Data GPH CMD Owner s Manual 9 BASIC OPERATION RECEIVE 1 Turn power on by turning the Volume knob clockwise A beep sounds indicating the radio is operatio...

Страница 9: ...ne Master Switch When the Master s Command Group is cloned to a slave the channel data that is pointed to by the Command Group is transferred to a target group not the Command Group in the slave The target group s label in the slave will be set to CMND CLN Data that can be cloned to a standard GPH radio includes Group data Command Group data When cloning to a GPH radio the Master s global data is ...

Страница 10: ...e transmitting or if Busy Channel operation is enabled check the yellow LED NOTE Do not transmit if the channel is busy 2 Press the PTT switch When the transmitter is on the red Transmit Indicator glows and TX appears in the display 3 If monitoring the channel reset the squelch knob to the Code Guard position to receive only the messages with the proper Code Guard value During extended transmissio...

Страница 11: ...arily shows CHAN DELETED and the following channels move up in the list For example if channel 5 is deleted channel 6 becomes the new channel 5 channel 7 becomes the new channel 6 etc When all channels are deleted the radio beeps continuously and the display shows CMND EMPTY along with the CMND icon Exit the Command Group to add new channels CMND full CMND Chan deleted SCN CMND LABEL 7 CMND cmnd e...

Страница 12: ...only the transmitter is disabled If an attempt is made to transmit an alert tone will be generated and the display will show the word BUSY until the channel becomes available or the PTT switch is released whether the Squelch knob is in or out of the Code Guard detent Channels not programmed with a receive Code Guard value can be used to transmit regardless of carrier activity BUSY GPH CMD Owner s ...

Страница 13: ... 7 8 9 0 CLR FCN PRI ENT SCN LABEL 3 LOCKED GPH CMD Owner s Manual 23 DTMF ENCODING Radios can be programmed to enable DTMF Dual Tone Multiple Frequency encoding To send DTMF tones similar to the tones used by a standard push button telephone 1 Press and hold the PTT switch 2 Press any of the keys on the keypad You will hear a sidetone The FCN PRI ENT and CLR keys respond as DTMF tones A B C and D...

Страница 14: ...ower level can be selected with a top switch or the keypad menu GPH CMD Owner s Manual 15 the channel selected by the Channel Selector knob When a signal is detected scanning stops and the message is received The received channel is shown in place of the transmit channel Once the signal ends the radio continues to monitor the channel for the preset scan delay time before it resumes scanning SCAN C...

Страница 15: ...s Manual 21 NOTE If the radio is programmed for Dual Priority operation only the Priority 1 channel can be changed with the PRI key NOTE A channel can be the priority channel even if it is on the Scan List Due to multiple sampling of the same channel however maximum performance occurs when the priority channels are not on the Scan List USER TRANSMIT CODE GUARD When the radio is being programmed wi...

Страница 16: ... 6 7 8 9 0 CLR FCN PRI ENT GPH CMD Owner s Manual 17 PRIORITY SCAN Priority Scan enables the radio to receive on any channel while monitoring for a message on the designated priority channel s The radio samples each priority channel at a preset rate 25 2 0 seconds regardless of activity on any other channel Priority Scan operates only while the radio is not transmitting and can be used in combinat...

Страница 17: ...y channel RX SCN LABEL 12 GPH CMD Owner s Manual 19 To reply to a message on the priority channel press the PTT switch and the radio will transmit on the priority channel Once activity ceases on the priority channel the radio returns to scan operation Priority Mode B With Switch C priority up and Switch B scan down the radio can receive on the knob selected channel while sampling the priority chan...