18                                                                                            BK Radio

 

Either priority channel can be programmed as 
a fixed channel, tied to the Channel Selector 
knob, or programmed OFF.  If the radio is 
programmed to transmit on the first priority 
channel, transmissions will occur on PR1 
when operating in Priority Scan Mode.  

If PR1 is a fixed channel, and the 

[PRI]

 key is 

not locked out, the user can  use the keypad to 
change groups, if necessary,  move the 
channel selector to a new channel and press 
the 

[PRI]

 key to choose a new PR1 channel. 

OLD-STYLE BK PRIORITY SCAN 

The radio can be programmed with one of 
three  Priority  Modes: A, B, or C. The table 
below  shows how the priority channels and 
the transmit channels are selected in each 
mode. 

 

Mode A 

Mode B 

Mode C 

Priority Channel 

Channel Knob 

Preset 

Preset 

Transmit Channel 

Channel Knob  Channel Knob 

Priority Channel 

 

Priority Mode A With Scan 

In Priority Mode A, the  priority channel is set 
by the Channel Selector knob. Priority Mode A 
is seldom used by itself because the radio 
receives and transmits only on the knob-
selected channel. 

When Switches B (scan) and C (priority) are 
up, scanning occurs until an active scan 
channel is found. The radio receives the 
message while continuing to check the priority 
channel. The display shows the scan channel.   

If the priority channel becomes active during 
this message, the  Priority  Indicator will light. 
The radio changes to the priority channel and 
holds for the duration of the message. The 
display shows the priority channel. 

              RX SCN 

  

LABEL     12   

 

 

 

 GPH-CMD Owner’s Manual                                                                19                                                           

To reply to a message on the priority channel, 
press the PTT switch and  the radio will 
transmit on the priority channel. Once activity 
ceases on the priority channel, the radio 
returns to scan operation. 

Priority Mode B 

With Switch C (priority) up and Switch B 
(scan) down, the radio can receive on the 
knob-selected channel while sampling the 
priority channel. If the priority channel 
becomes active,  the Priority  Indicator lights 
up. The radio changes to the priority channel 
and holds for the duration of the transmission.   

To reply to a message on the priority channel, 
use the keypad to change groups if necessary, 
turn the Channel Knob to select the priority 
channel, and then transmit. 

Priority Mode B with Scan 

With Switches B (scan) and C (priority) up, the 
radio scans until it locks on to an active 
channel. The radio continues to sample the 
priority channel while listening to the active 
scan channel. 

If activity occurs on the priority channel, the 
radio overrides the active scan channel, 
changes to the priority channel, and holds for 
the duration of the transmission.   

To reply to a message on the priority channel, 
use the keypad to change groups if necessary, 
turn the Channel  K nob  to select the priority 
channel, and then transmit. 

Once activity has ceased on the priority 
channel, the radio returns to scan operation. 

Priority Mode C  

With Switch C (priority) up and Switch B 
(scan) down, the radio samples the fixed 
priority channel at the preset rate. If activity 
occurs on the priority channel, the radio 
changes to the priority channel and holds for 
the duration of the transmission.   

PR         RX SCN 

  

LABEL      3    

 

 

 

 

 

 

 

Содержание GPH-CMD

Страница 1: ...Technology Drive West Melbourne FL 32904 Telephone 321 984 1414 FAX 321 984 0434 www relm com Copyright 2005 RELM Wireless Corporation All rights reserved P N 7001 30969 300 03 02 GPH CMD PORTABLE RADIO OWNERS MANUAL ...

Страница 2: ...mation 5 Radio Controls 8 Basic Operation 9 Code Guard Operation 10 Command Group 11 Channel Groups 13 Programmable Top Switches Function Menu 13 Scan Operation 14 Priority Scan 17 User Transmit Code Guard 21 Other Operational Features 22 Alphanumeric Display 25 Cloning Procedure 26 Battery Installation And Removal 29 Definitions And Acronyms 31 Service Inside Back Cover ...

Страница 3: ...Your radio must be properly licensed by the Federal Communications Commission prior to use Your BK Radio dealer can assist you in meeting these requirements Your dealer will program each radio with your authorized frequencies signaling codes etc and will be there to meet your communications needs as your system expands SAFETY PRECAUTIONS Do not operate the transmitter in close proximity to blastin...

Страница 4: ...nergy which when used improperly can cause biological damage Very high levels of x rays for example can damage tissues and genetic m aterial The energy levels associated with radio waves from portable 2 way radios when properly used are not great enough to cause biological damage Experts in science engineering medicine health and industry work with organizations to d evelop standards for exposure ...

Страница 5: ... up to 50 talk Your BK Radio 2 way radio complies with the following RF energy exposure standards and guidelines United States Federal Communications Commission Code of Federal Regulations 47 CFR 1 1307 1 1310 2 1091 and 2 1093 American National Standards Institute ANSI Institute of Electrical and Electronic Engineers IEEE C95 1 1992 Institute of Electrical and Electronic Engineers IEEE C95 1 1999...

Страница 6: ...ecause this radio generates measurable RF energy exposure only when transmitting in terms of measuring for standards compliance Hold the radio in a vertical position in front of face with the microphone and the other parts of the radio including the antenna at least one inch 2 5 cm away from the nose Keeping the radio at the proper distance is important because RF exposures decrease with distance ...

Страница 7: ...tiple beeps will follow Failure of downloading can be due to Improper connection Failure to turn on the clone Setting the clone in Programming Mode Target radio s group locked by PC Programming NOTE To stop the FAILURE Mode press CLR turn off both radios and try again starting with Step 1 on the previous page BATTERY INSTALLATION AND REMOVAL BK Radio battery packs are available in a variety of siz...

Страница 8: ...LR key Navigate to a CH prompt then press and hold the key to get the GRP prompt CLONING Group 01 PROG GPHcmD Group 01 PROG GPH Group 01 Press and Hold Key to Change Target PROG GPHcmD Cmnd group PROG GPHcmD pick list Press and Hold Key to Change Data GPH CMD Owner s Manual 9 BASIC OPERATION RECEIVE 1 Turn power on by turning the Volume knob clockwise A beep sounds indicating the radio is operatio...

Страница 9: ...ne Master Switch When the Master s Command Group is cloned to a slave the channel data that is pointed to by the Command Group is transferred to a target group not the Command Group in the slave The target group s label in the slave will be set to CMND CLN Data that can be cloned to a standard GPH radio includes Group data Command Group data When cloning to a GPH radio the Master s global data is ...

Страница 10: ...e transmitting or if Busy Channel operation is enabled check the yellow LED NOTE Do not transmit if the channel is busy 2 Press the PTT switch When the transmitter is on the red Transmit Indicator glows and TX appears in the display 3 If monitoring the channel reset the squelch knob to the Code Guard position to receive only the messages with the proper Code Guard value During extended transmissio...

Страница 11: ...arily shows CHAN DELETED and the following channels move up in the list For example if channel 5 is deleted channel 6 becomes the new channel 5 channel 7 becomes the new channel 6 etc When all channels are deleted the radio beeps continuously and the display shows CMND EMPTY along with the CMND icon Exit the Command Group to add new channels CMND full CMND Chan deleted SCN CMND LABEL 7 CMND cmnd e...

Страница 12: ...only the transmitter is disabled If an attempt is made to transmit an alert tone will be generated and the display will show the word BUSY until the channel becomes available or the PTT switch is released whether the Squelch knob is in or out of the Code Guard detent Channels not programmed with a receive Code Guard value can be used to transmit regardless of carrier activity BUSY GPH CMD Owner s ...

Страница 13: ... 7 8 9 0 CLR FCN PRI ENT SCN LABEL 3 LOCKED GPH CMD Owner s Manual 23 DTMF ENCODING Radios can be programmed to enable DTMF Dual Tone Multiple Frequency encoding To send DTMF tones similar to the tones used by a standard push button telephone 1 Press and hold the PTT switch 2 Press any of the keys on the keypad You will hear a sidetone The FCN PRI ENT and CLR keys respond as DTMF tones A B C and D...

Страница 14: ...ower level can be selected with a top switch or the keypad menu GPH CMD Owner s Manual 15 the channel selected by the Channel Selector knob When a signal is detected scanning stops and the message is received The received channel is shown in place of the transmit channel Once the signal ends the radio continues to monitor the channel for the preset scan delay time before it resumes scanning SCAN C...

Страница 15: ...s Manual 21 NOTE If the radio is programmed for Dual Priority operation only the Priority 1 channel can be changed with the PRI key NOTE A channel can be the priority channel even if it is on the Scan List Due to multiple sampling of the same channel however maximum performance occurs when the priority channels are not on the Scan List USER TRANSMIT CODE GUARD When the radio is being programmed wi...

Страница 16: ... 6 7 8 9 0 CLR FCN PRI ENT GPH CMD Owner s Manual 17 PRIORITY SCAN Priority Scan enables the radio to receive on any channel while monitoring for a message on the designated priority channel s The radio samples each priority channel at a preset rate 25 2 0 seconds regardless of activity on any other channel Priority Scan operates only while the radio is not transmitting and can be used in combinat...

Страница 17: ...y channel RX SCN LABEL 12 GPH CMD Owner s Manual 19 To reply to a message on the priority channel press the PTT switch and the radio will transmit on the priority channel Once activity ceases on the priority channel the radio returns to scan operation Priority Mode B With Switch C priority up and Switch B scan down the radio can receive on the knob selected channel while sampling the priority chan...