Страница 1: ...i 9130C Series Triple Output Programmable DC Power Supplies Models 9130C 9131C 9132C USER MANUAL...

Страница 2: ...es that may occur on electrical conductors associated with these category ratings The category rating is a Roman numeral of I II III or IV This rating is also accompanied by a maximum voltage of the c...

Страница 3: ...tlet The power jack and mating plug of the power cable meet IEC safety standards Do not alter or defeat the ground connection Without the safety ground connection all accessible conductive parts inclu...

Страница 4: ...d appears to be damaged or if any liquid chemical or other material gets on or inside the instrument remove the instrument s power cord remove the instrument from service label it as not to be operate...

Страница 5: ...procedures Disconnect the instrument from the power line before replacing fuses Replace fuses only with new fuses of the fuse types voltage ratings and current ratings specified in this manual or on t...

Страница 6: ...without the wire overheating For continued safe use of the instrument Do not place heavy objects on the instrument Do not obstruct cooling air flow to the instrument Do not place a hot soldering iron...

Страница 7: ...C of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market a...

Страница 8: ...ents of 2006 95 EC Low Voltage Directive and 2004 108 EC Electromagnetic Compatibility Directive with the following standards Low Voltage Directive EN61010 1 2001 EMC Directive EN 61000 3 2 2006 EN 61...

Страница 9: ...s connect disconnect switch on the front of the instrument Direct current Alternating current Fuse Symbol Chassis earth ground symbol Ground terminal Protective earth ground CAUTION indicates a hazard...

Страница 10: ...1 Input Power and Fuse Requirements 9 2 2 Fuse Requirements 10 2 3 Line Voltage Selection 10 2 4 Output Connections 12 2 5 Carrying handle Adjustment 13 2 6 Preliminary Check 14 3 Front Panel Operatio...

Страница 11: ...4 4 11 System Menu 25 4 12 Combined Series and Parallel Modes 26 4 13 Tracking Mode 29 4 14 Parameters in Series Parallel Mode 30 4 15 Over Temperature Protection 30 4 16 Remote Sense 30 5 Remote Oper...

Страница 12: ...and Current of all 3 channels simultaneously RS232 and USB remote interfaces Series parallel and tracking modes Output timer function 0 1 99999 9 seconds Store recall up to 36 instrument settings Bri...

Страница 13: ...imately 214 5 mm 8 44 in x 88 2 mm 3 47 in x 354 6 mm 13 96 in W x H x D The 9131C and 9232C power supply s dimensions are approximately 214 5 mm 8 44 in x 88 2 mm 3 47 in x 445 mm 17 52 in W x H x D...

Страница 14: ...T E151 rackmount kit Note Remove the carrying handle and the two plastic ears before mounting the instrument To remove the handle grasp the handle by its sides pull outwards and rotate it until the ar...

Страница 15: ...4 To rackmount a single instrument order rackmount kit IT E151 To rackmount two instruments side by side order rackmount kit IT E151 and remove the front panel cover...

Страница 16: ...5 1 5 Front Panel Overview Figure 1 Front Panel Front Panel Description VFD display Shift key Local key Power key Numeric keys Function keys Cursor keys Output terminals Rotary knob 1 2 3 4 5 6 7 8 9...

Страница 17: ...6 1 6 Rear Panel Overview Figure 2 Rear Panel Rear Panel Description Cooling fan Remote sense terminal AC power input receptacle fuse box RS 232 interface USB interface 1 2 3 4 5...

Страница 18: ...ly I set Menu button Configures output current or allows access to the power supply menu settings Recall Save button Saves and recalls instrument settings Meter Switches from set value display to meas...

Страница 19: ...y Description Indicates output is off Indicates constant voltage mode Indicates constant current mode Indicates the shift button is pressed Tracking mode enabled Indicates remote mode Keyboard lock en...

Страница 20: ...d including the extension line is compatible with the rated voltage current and that there is sufficient circuit capacity for the power supply Once verified connect the cable firmly The included AC po...

Страница 21: ...strument is properly configured to operate at the desired AC line voltage please follow the steps below For safety no power should be applied to the instrument while changing line voltage operation Di...

Страница 22: ...esired line voltage operation Figure 6 Line Voltage Switch Location Do not connect power to the instrument until the line voltage selection is setup correctly Applying an incorrect line voltage or con...

Страница 23: ...power supply operates at maximum short circuit output current It will also prevent large voltage drops from resistances in the wires SHOCK HAZARD Hazardous voltages may exist at the outputs and the lo...

Страница 24: ...e sides and pull outward Then rotate the handle to the desired position Bench operation Handle transport position Be sure the handle is locked in position and avoid twisting movements while transporti...

Страница 25: ...use Requirements 2 Connect Power and Self Test Connect AC power cord to the AC receptacle in the rear panel and press the power switch to the ON position to turn ON the instrument It will run through...

Страница 26: ...EPROM Fail The internal EEPROM is corrupted or damaged System Lost Last system settings within the EEPROM are lost Model Fail Channel response failure Cal Lost Calibration data within the EEPROM is lo...

Страница 27: ...e and current The output of the power supply can be enabled disabled from the front panel by pressing the button When output is enabled the supply will display the state and voltage current of each ch...

Страница 28: ...e Then enter a numerical value on the keypad followed by 2 Using the rotory knob Press key to select channel selected channel is indicated by press for voltage or for current then press to move the cu...

Страница 29: ...g 120 of the rated voltage across the output terminals or it will damage the power supply 3 6 Save Recall Instrument Settings Up to 36 instrument settings can be saved recalled from the instrument s i...

Страница 30: ...ll light up on the display indicating that the front panel keys are locked At this point all keys are disabled except for the key button and button 2 To unlock the keys press the key and button again...

Страница 31: ...test leads or a shorting bar 3 Set the power supply to settings mode press so that it is not illuminated 4 Press the button first and then enter the value i e 1 000 A on the keypad and press the butto...

Страница 32: ...steps to select them 4 To save changes to a setting press the button To exit the menu at any time press the key multiple times Each press exits out of a submenu 4 2 Menu Options All settings and param...

Страница 33: ...output state values at power on 1 From the Config menu select OutParam and press the button 2 There are two options that can be selected using the curser keys or rotary knob 3 Reset Restores the defa...

Страница 34: ...menu select RS 232 and press the button This will select the RS 232 interface for remote communication 2 There are four options that can be selected by using the keys or rotary knob 3 Use the to sele...

Страница 35: ...t Protocol and press the button There are three options DEFAULT EXT1 LEGACY Select one of the options by using the keys or rotary knob and press the button The DEFAULT option is recommended for most a...

Страница 36: ...s this menu press key and then press the button Use the keys to select CH1 CH2 or CH3 and press the button Use the keys to select MaxVolt OutTimer or Exit and then press the button MaxVolt This allows...

Страница 37: ...followed by the button The display will show four menu options OFF Series Para Track Each of these options are described below Figure 8 Normal Wiring OFF This option is used to disable series parallel...

Страница 38: ...l be shown in the middle of the display Figure 10 Display Series CH1 2 6 Set the voltage and current for CH1 2 and CH3 7 Enable the outputs by pressing the button 8 If the button is not illuminated pr...

Страница 39: ...Successful Figure 12 CH1 CH2 Parallel Display 7 Set the voltage and current max current will be the sum of the combined channels 8 Enable the outputs by pressing the enter button which will illuminat...

Страница 40: ...on The power supply will display Parallel Successful Figure 14 All Channels Parallel Display 4 13 Tracking Mode This function configures the channels for tracking mode In tracking mode when a voltage...

Страница 41: ...V 122 V Parallel CH1 CH2 Max Voltage 31 V 31 V 62 V Parallel CH2 CH3 Max Voltage 6 V 6 V 6 V Parallel CH1 CH2 CH3 All Max Voltag e 6 V 6 V 6 V 4 15 Over Temperature Protection If the internal temperat...

Страница 42: ...designed to tighten wires to the terminals Doing so may create a shock hazard under high voltage output conditions Remote Sense To enable remote sense follow the steps below for each channel 1 Power...

Страница 43: ...interfaces Users can program the power supply by using SCPI Standard Commands for Programmable Instruments commands over any one of the remote interfaces This section will describe how to set up all o...

Страница 44: ...one 8 bits default Even 8 bits Odd 8 bits Address Single Mux 3 Use the keys to select the option and the keys to change settings When all three options are set press the button 4 If MUX mode has been...

Страница 45: ...ces USBTMC and RS 232 Refer to the programming manual for details which can be downloaded from www bkprecision com 7 Troubleshooting Guide Below are some frequently asked questions and answers Please...

Страница 46: ...of the voltage maximum limit Refer to the MaxVolt section of the manual and set this value above the voltage that is being entered This can also be set to the limit of the power supplies range which i...

Страница 47: ...3 A Ch 1 and Ch2 0 3 A Ch3 0 6 A Ch 1 and Ch2 0 3 A Ch3 0 3 A Ch 1 and Ch2 0 3 A Ch3 Power 195 W 375 W 375 W Line Regulation Voltage 0 01 3 mV 0 01 3 mV 0 01 3 mV Current 0 1 3 mA 0 1 3 mA 0 1 3 mA L...

Страница 48: ...9 locations in each group Remote Interface USB USBTMC compliant RS 232 AC Input 110 220 VAC 10 47 Hz 63 Hz Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 158 F 20 C to 70 C...

Страница 49: ...nch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 11 LIM...

Страница 50: ...22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2015 B K Precision Corp Printed in China v020322...