This instrument is intended to be used in an indoor pollution degree 2 environment. The operating 
temperature range is 

0 °C to 40 °C

 and the operating humidity range is 

≤ 95%

 relative humidity with no 

condensation allowed. 
Measurements made by this instrument may be outside specifications if the instrument is used in non-office-
type environments. Such environments may include rapid temperature or humidity changes, sunlight, vibration 
and/or mechanical shocks, acoustic noise, electrical noise, strong electric fields, or strong magnetic fields. 

Do not operate instrument if damaged 

If the instrument is damaged, appears to be damaged, or if any liquid, chemical, or other 

material gets on or inside the instrument, remove the instrument's power cord, remove the instrument from 
service, label it as not to be operated, and return the instrument to B&K Precision for repair. Notify B&K 
Precision of the nature of any contamination of the instrument. 

Clean the instrument only as instructed 

 

Do not clean the instrument, its switches, or its terminals with contact cleaners, abrasives, lubricants, solvents, 
acids/bases, or other such chemicals. Clean the instrument only with a clean dry lint-free cloth or as instructed 
in this manual. 

Not for critical applications 

Содержание 601B

Страница 1: ...Model 601B SLA Battery Capacity Analyzer USER MANUAL...

Страница 2: ...line voltage will void the warranty Make all connections to the instrument before applying power Do not operate the instrument in ways not specified by this manual or by B K Precision Failure to comp...

Страница 3: ...s are meant to be connected to the mains supply at a standard wall outlet or similar sources Example measurement environments are portable tools and household appliances Category III CAT III Measureme...

Страница 4: ...ffice type indoor environments Do not operate the instrument In the presence of noxious corrosive or flammable fumes gases vapors chemicals or finely divided particulates In relative humidity conditio...

Страница 5: ...g magnetic fields Do not operate instrument if damaged If the instrument is damaged appears to be damaged or if any liquid chemical or other material gets on or inside the instrument remove the instru...

Страница 6: ...avoid injuries always disconnect the power cord from the instrument disconnect all other connections for example test leads computer interface cables etc discharge all circuits and verify there are no...

Страница 7: ...instrument to B K Precision for service and repair to ensure that safety and performance features are maintained For continued safe use of the instrument Do not place heavy objects on the instrument D...

Страница 8: ...Section 1 General Description 9 1 1 INTRODUCTION 9 1 2 APPLICATIONS 9 1 3 SPECIFICATIONS 9 Section 2 Operation 10 2 1 Front Panel Controls 10 2 2 Operating Procedure 11 Service Information 14 Limited...

Страница 9: ...nance will increase along with increasing demand for UPS The 601B can be applicable for Automobile Service Stations UPS Manufacturing Maintenance and Field Servicing QC Department Battery Systems in R...

Страница 10: ...this key the user can decrease the Ah values 4 Test On pressing this key the measurement will begin 5 Repeat Test This key is used to repeat previously performed test 6 Reverse Polarity LED This LED...

Страница 11: ...1B performs a memory test displays open circuit voltage on LCD CAUTION Do not connect the ve terminal of 601B to ve terminal of BUT and ve terminal of 601B to ve terminal of BUT On doing so the Revers...

Страница 12: ...h off during the test TEST INPROGRESS 12 53V 028AH The results will be displayed as follows 12 37V 61 87 CAP IR 39 2 mOhm The first field indicates the battery terminal voltage when battery was loaded...

Страница 13: ...t press SELECT Ah key in order to repeat the same test press TEST REPEAT key To prevent unnecessary discharge of BUT the unit will switch off automatically after 5 minutes of non operational period 1...

Страница 14: ...s probes connectors and accessories that you are using with the device Customers not on an open account must include payment in the form of a money order or credit card For the most current repair cha...

Страница 15: ...nstrument via our website www bkprecision com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty...

Страница 16: ...irements of 2006 95 EC Low Voltage Directive and 2004 108 EC Electromagnetic Compatibility Directive with the following standards Low Voltage Directive EN61010 1 2001 EMC Directive EN61326 1 2013 CISP...

Страница 17: ...17 B K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda California 92887 www bkprecision com 2015 B K Precision Corporation Printed in Taiwan 120815...

Отзывы: