Common Command Introduction
22
Example
Set amplitude coupling ratio
COUP ARAT,2
Query coupling information.
COUP?
Return:
COUP\sTRACE,OFF,FCOUP,ON,PCOUP,ON,ACOUP,ON,FDEV,5HZ,
PRAT,1,ARAT,2\n
2.29 Voltage Overload Command
Description
Sets or gets state of over-voltage protection.
Command Syntax
VOLTPRT<parameter> <parameter>={ON, OFF}
Query Syntax
VOLTPRT?
Response Format
VOLTPRT<parameter>
2.30 Store List Command
Description
This command is used to read the stored wave data names if the store unit is empty; the command will return “EMPTY”
string.
Note:
M50~ M59 is user defined memory. The name will return what you defined. if you do not define an arbitrary
name, it will return
“
EMPTY”(It is depends on the model).
Query Format
STL (StoreList)? BUILDIN, USER
Example
Read all arbitrary data saved in the device.
STL?
Return:
STL M0, StairUp, M1, StairDn, M2, StairUD, M3, Trapezia, M4,ExpFall,
M5, ExpRise, M6, LogFall, M7, LogRise, M8, Sqrt, M9, X^2, M10, Sinc, M11
, Gaussian, M12, Dlorentz, M13, Haversine, M14, Lorentz, M15, Gauspuls, M16, Gmonopuls
, M17, Cardiac,M18, Quake, M19, TwoTone, M20, SNR, M21, Hamming, M22, Hanning, M23, Kaiser,
M24, Blackman, M25, GaussiWin, M26, Harris, M27, Bartlett, M28, Tan, M29, Cot, M30,
Sec, M31, Csc, M32, Asin, M33, Acos, M34, Atan, M35, ACot, M36, EMPTY, M37 .
…
.
Read built-in wave data.
STL? BUILDIN
Return:
STL M0, Sine, M1, Noise, M10, ExpFal, M11, ExpRise, M12, LogFall, M13,
LogRise, M14, Sqrt, M15, Root3, M16, X^2, M17, X^3, M18, Sinc, M19,
Gussian, M2, StairUp, M20, Dlorentz, M21, Haversine, M22, Lorentz, M23, Gauspuls,
M24, Gmonopuls, M25, Tripuls, M26, Cardiac, M27, Quake,
M28, Chirp, M29, Twotone, M3, StairDn, M30, SNR, M31,
Hamming, M32, Hanning, M33, kaiser, M34, Blackman, M35,
Gausswin, M36, Triang, M37, Harris, M38, Bartlett, M39, Tan,
M4, StairUD, M40, Cot, M41, Sec, M42, Csc, M43, Asin, M44,
Содержание 4060B Series