APPLICATIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ELECTRONICS  DESIGN  LAB  

 

The technician or engineer working in an engineering laboratory 

requires  a  dc  power  supply  to  power  breadboard  and  prototype 
circuits.  This  power  supply  is  ideal  because  it  monitors  output 
current,  output  voltage,  limits  current  to  protect  the  circuit,  is 
adjustable over a wide range, and has excellent regulation and very 
low ripple. 

 
Use  of  the  instrument  in  an  engineering  laboratory  is  very 

similar  to  that  described  for  servicing  electronics  equipment  and 
modules,  except  that  lower  currents  may  be  prevalent  when 
powering  individual  circuits.  The  current  limiting  feature  is  very 
valuable in this application because it can protect unproven circuits 
from damage. 
 

ELECTRONICS  EDUCATION  

 

The  student  in  an  electronics  curriculum  may  use  the  power 

supply  for  powering  equipment  and  circuits  as  previously 
described  for  all  other  applications.  In  addition,  the  power  supply 
can be used in the classroom laboratory to conduct experiments in 
fundamental  electronics.  In  learning  Ohm’s  law,  for  example,  the 
relationships  of  resistance,  current,  and  voltage  are  easily 
demonstrated by the use of a power supply.  Being able to observe 
both the current and voltage meter simultaneously is a great aid in 
such experiments.  

 

BATTERY  CHARGING  

 

The  power  supply  can  be  used  as  a  battery  charger  to 

restore the charge in rechargeable batteries such as lead-acid, 
nickel-cadmium,  and  some  alkaline  types.  Refer  to  the 
battery  manufacturer’s  charging  specifications  for  proper 
voltage  and  current  settings.  Charging  information  is 
sometimes printed on the batteries. Battery charging, at least 
initially,  requires  the  constant  current  mode  of  operation. 
Before connecting the power supply to the battery, preset the 

VOLTAGE

  controls  to  the  fully  charged  terminal  voltage 

specified  by  the  battery  manufacturer.  Turn  off  the  power 
supply while connecting the battery. Observe proper polarity 
and  connect  as  for  constant  current  operation.  Adjust  the 

CURRENT

  control  for  the  maximum  charging  current 

specified  by  the  battery  manufacturer.  (If  the  maximum 
charging current is greater than the power supply’s maximum 
load  current,  set  the 

CURRENT

  control  to  maximum).  The 

CC

  indicator  will  light  and  the  battery  will  charge  at  the 

preset current limit. As the battery approaches full charge, its 
terminal  voltage  will  approach  that  of  the  power  supply 
output  and  the  charging  current  will  taper  off.  The  power 
supply  may  automatically  switch  to 

CV

  (constant  voltage) 

operation.  When  this  occurs,  the  power  supply  will  continue 
to provide a trickle charge. 

 

21 

Содержание 1743B

Страница 1: ...0 35 V 0 6 A DC POWER SUPPLY With Dual 4 Digit LED Displays Fuente de Poder de DC con Doble LED indicador 0 35V 0 6A INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES Model 1743B Modelo 1743B...

Страница 2: ...s shock hazard exists unless the equipment is unplugged just turning off the equipment does not remove the hazard or an isolation transformer is used b If the equipment under test is powered up and th...

Страница 3: ...rent Operation 15 Constant Voltage Constant Current Characteristic 16 Connecting Two Power Supplies in Series 16 Connecting Two Power Supplies in Parallel 19 Page APPLICATIONS 20 General 20 Electronic...

Страница 4: ...load variations cause the current to reach the preset limit the unit then regulates output current rather than output voltage Current limits are adjustable from 5 to 100 of maximum In constant curren...

Страница 5: ...read LED digit displays monitors output voltage and output current and provides good visibility in bright or low light LED INDICATORS Act as pilot light and identify mode of operation and metering PRE...

Страница 6: ...0 PPM C CONSTANT CURRENT OPERATION Adjustable Current Limits 5 to 100 Current Regulation Line 108 132 V 0 4 5 mA Load 0 4 5 mA Current Ripple 3 mA typical METERING Voltmeter 4 digit Green LED Display...

Страница 7: ...pes Thermal Drift results in the metering of the power supply to either slowly increase or decrease with the change in the power supply s internal temperature As the power supply outputs more power it...

Страница 8: ...inuously monitors voltage 4 RED LED Display 4 digit display continuously monitors current VOLTAGE CONTROLS 5 Coarse Control Coarse adjustment of output voltage Read value on GREEN LED display 6 Fine C...

Страница 9: ...9 CONTROLS AND INDICATORS Figure 1 Front Panel Controls and Indicators Figure 2 Rear Panel REAR PANEL CONTROLS 7 Fuse 8 Power Cord 9 110 220 Line Voltage Conversion Switch...

Страница 10: ...ild up Although the power supply is protected against reverse polarity damage the circuit being powered may not include such protection Always carefully observe polarity incorrect polarity may damage...

Страница 11: ...OPERATING INSTRUCTIONS 11 Figure 3 A and B Grounding Possibilities...

Страница 12: ...12 OPERATING INSTRUCTIONS Figure 3 C and D Grounding Possibilities...

Страница 13: ...the circuit can result from reverse polarity Use color coded hook up leads for convenience in identifying polarity red for and black for 6 Make sure that the hook up leads offer sufficient current ca...

Страница 14: ...ion of the VOLTAGE control will not increase the output voltage SETTING CURRENT LIMIT 1 Determine the maximum safe current for the device to be powered 2 Temporarily short the and terminals of the pow...

Страница 15: ...power supply and connect it to the device to be powered 5 Turn on the power supply The CC indicator should light 6 Increase the Coarse and Fine CURRENT control setting until the desired constant curr...

Страница 16: ...t voltage mode automatically occurs from a decrease in load A good example of this would be seen when charging a 12 volt battery Initially the open circuit voltage of the power supply may be preset fo...

Страница 17: ...OPERATING INSTRUCTIONS Figure 8 Connecting Two Power Supplies in Series 17...

Страница 18: ...18 OPERATING INSTRUCTIONS Figure 9 Connecting Two Power Supplies in Parallel...

Страница 19: ...lue Then when the load is connected set the VOLTAGE controls on the two power supplies for equal voltage readings This should also provide approximately equal current from each supply Add the two curr...

Страница 20: ...ests such as checking the effect of AGC bias in a television receiver This requires an isolated dc power supply such as the Model 1743B The equipment being tested may contain its own power supply and...

Страница 21: ...and voltage meter simultaneously is a great aid in such experiments BATTERY CHARGING The power supply can be used as a battery charger to restore the charge in rechargeable batteries such as lead aci...

Страница 22: ...OPERATION FUSE VALUE TYPE 120 V 3 5 A SLOW BLOW 220 230 240 V 1 75 A SLOW BLOW Table 1 Fuse Values LINE VOLTAGE CONVERSION INTERNATIONAL UNITS The primary winding of the power transformer is tapped to...

Страница 23: ...00 volts on the Multimeter Adjust upper GREEN R304 for a front panel meter reading of 35 00 volts on the GREEN VOLTAGE meter 1 Set the front panel Coarse VOLTAGE control for a reading of 04 00 to 06 0...

Страница 24: ...MAINTENANCE Figure 11 Location of Adjustments 24...

Страница 25: ...ount must include payment in the form of a money order or credit card For the most current repair charges please visit www bkprecision com and click on service repair Return all merchandise to B K Pre...

Страница 26: ...om within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void...

Страница 27: ...off switch fuses power transformer etc any time the equipment is connected to an ac outlet 7 B K Precision products are not authorized for use in any application involving direct contact between our...

Страница 28: ...22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2002 B K Precision Corp V072814 Printed in Taiwan...

Отзывы: