BJM Pumps R08 Скачать руководство пользователя страница 4

 

 

INTRODUCTION 

This Installation, Operation and Maintenance manual provides important information on 
safety  and  the  proper  inspection,  disassembly,  assembly  and  testing  of  the  BJM 
Pumps®  R  &  RX  Series  submersible  pump.  This  manual  also  contains  information  to 
optimize performance and longevity of your

 BJM Pumps

 submersible pump. 

 

The  submersible  R  Series  pumps  are  designed  to  pump  water.  The  RX  Series 
pumps  are  designed  to  pump  corrosive  liquids  in  concentrations  chemically 
compatible  with  316SS  and  FKM.  The  R  &  RX  Series  pumps  are  not  explosion-
proof. They are not designed to pump volatile or flammable liquids. 
 
Note:  Consult  chemical  resistance  chart  for  compatibility  between  pump 
materials and liquid before operating pump. 

 
If  you  have  any  questions  regarding  the  inspection,  disassembly,  assembly  or  testing 
please contact your 

BJM Pumps

 distributor, or BJM Pumps, LLC. 

 
BJM Pumps, LLC 
123 Spencer Plain Rd. 

 

 

 

Old Saybrook, CT 06475, USA 

 

 

Fax:   860-399-7784 
Phone: 877-256-7867 
Phone: 860-399-5937 
 

Information,  including  pump  data  sheets  and  performance  curves,  is  also  available  on 
our web site: 

www.bjmpumps.com

 

 
For assistance with your electric power source, please contact a certified electrician. 
 
Please  pay  attention  to  the  following  alert  notifications.  They  are  used  to  notify 
operators  and  maintenance  personnel  to  pay  special  attention  to  procedures,  to  avoid 
causing  damage  to  the  equipment,  and  to  avoid  situations that  could  be  dangerous  to 
personnel.  

NOTE:  Instructions  to  aid  in  installation,  operation,  and  maintenance  or  which 
clarify a procedure. 

 

 

Immediate  hazards  that  WILL  result  in  severe  personal  injury  or 

death.  These  instructions  describe  the  procedure  required  and  the  injury  which  will 
result from failure to follow the procedure. 

 

Hazards or unsafe practices that COULD result in severe personal 

injury or death. These instructions describe the procedure required, and the injury which 
could result from failure to follow the procedure. 

 

Hazards or unsafe practices which COULD result in personal injury 

or product or property damage. These instructions describe the procedure required and 
the possible damage which could result from failure to follow the procedure. 

SAFETY 

Pump installations are seldom identical. Each installation and application can vary due 
to  many  different  factors.  It  is  the  owner/service  mechanics  responsibility  to  repair, 

Содержание R08

Страница 1: ...THREE PHASE R100 R250 R400 R400D R400P R750 R1500 R1520 R1530 R08 R15 316 STAINLESS STEEL SINGLE PHASE THREE PHASE RX750SS RX1500SS RX08SS RX15SS Read this manual carefully before installing operating...

Страница 2: ......

Страница 3: ...T MAY NEED TO BE PRIMED 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF R100 16 EXPLODED VIEW OF R250 R400 R400D R400P 17 EXPLODED VIEW OF R750 RX7...

Страница 4: ...b site www bjmpumps com For assistance with your electric power source please contact a certified electrician Please pay attention to the following alert notifications They are used to notify operator...

Страница 5: ...attempt to alter the length or repair any power cable with a splice The pump motor and pump motor and cable must be completely waterproof Damage to the pump or personal injury may result from alterat...

Страница 6: ...mps distributor or BJM Pumps LLC If damaged the pump may need to be repaired before use Do not install or use the pump until appropriate action has been taken Lubrication No additional lubrication is...

Страница 7: ...e pump dry for extended periods of time Refer to data sheet for minimum submersion depth for your particular model Data sheets can be obtained online at www bjmpumps com or by calling BJM Pumps LLC at...

Страница 8: ...ld be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the...

Страница 9: ...anty considerations Always keep the plug end dry Note 230V single phase and 208V 230V 460V 575V three phase units do not have a plug and have to be provided separately Do not alter the length or repai...

Страница 10: ...or turn the power source off generator Typical 3 phase manual control 1 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE Maximum recommended starts should not exceed 10 times per hour AUTOMATIC OPERATI...

Страница 11: ...urce turn off the breaker or turn the power source off generator INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARREAR APP...

Страница 12: ...o not remove power supply cord and strain relief or connect conduit directly to the pump Installation and checking of electrical circuits and hardware should be performed by a qualified licensed elect...

Страница 13: ...g device also incorporate motor overload protection Pumps must be installed in accordance with the National Electrical Code and all applicable local codes and ordinances Pumps are not to be installed...

Страница 14: ...ck 4 Pumping air Check liquid level and position of pump 5 Excessive voltage drops due to long cables 6 Three phase only pump running backwards check rotation R400D ONLY NOTE THIS UNIT MAY NEED TO BE...

Страница 15: ...power cable Make sure that it is free of nicks or cuts CHANGING SEAL OIL Changing the seal oil in the R series pumps is very easy 1 Make sure that the pump cable is disconnected from the power source...

Страница 16: ...16 EXPLODED VIEW OF R100...

Страница 17: ...17 EXPLODED VIEW OF R250 R400 R400D R400P...

Страница 18: ...18 EXPLODED VIEW OF R750 RX750SS R1500 RX1500SS R1520 R1530...

Страница 19: ...19 EXPLODED VIEW OF R08 RX08SS R15 RX15SS...

Страница 20: ...258 202258 202258 202258 202258 13 Mechanical Seal Buna N 202269 202259 202259 202259 202259 200501 200501 200501 200501 200501 200501 13 Mechanical Seal FKM 202260 202260 202260 202260 200500 200500...

Страница 21: ...Screw for Strainer 202691 50 01 2 Screw for Bottom Plate 202689 202689 202689 203220 203220 203220 203220 203220 203220 50 01 3 Stud with Nuts R400D 202688 50 07 Screw for Suction Cover 203233 203239...

Страница 22: ...al Buna N Optional 200501 200501 200501 200501 14 Lower Ball Bearing 200958 200958 200958 200958 15 Impeller Shim Kit Required 200481 200481 200480 200480 16 Pump Casing Outer 202292 202294 202292 202...

Страница 23: ...202568 202568 202568 202568 50 01 2 Screw for Bottom Plate 203220 203220 203220 203220 50 07 Screw for Suction Cover 203250 203250 203250 203250 50 08 Screw for Oil Chamber Cover 203219 203219 203219...

Страница 24: ...24 SINGLE PHASE WIRING DIAGRAM 115V 230V W O GOVERNOR SWITCH MODELS R100 R250 R400 R400D R400P...

Страница 25: ...25 SINGLE PHASE WIRING DIAGRAM 115V 230V W GOVERNOR SWITCH MODELS R750 RX750SS R1500 RX1500SS R1520 R1530...

Страница 26: ...26 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 230V...

Страница 27: ...27 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 460V...

Страница 28: ...IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS EXPENSE DAMA...

Страница 29: ...29...

Страница 30: ...r Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counterclockwise Method used to check rotation viewed from bottom Resistance of ca...

Страница 31: ...top Yes No Control Panel MFG model no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit pr...

Страница 32: ...hecked for leaks Yes No Do check valves operate properly Yes No Flow Does station appear to operate at proper rate Yes No Noise level Acceptable Unacceptable Comments Describe and equipment difficulti...

Страница 33: ...NOTES...

Страница 34: ...k of BJM Pumps LLC Copyright 2006 2013 BJM Pumps LLC All rights reserved BJM Pumps LLC 123 Spencer Plain Road PO Box 1138 Old Saybrook CT 06475 USA Phone 860 399 5937 Fax 860 399 7784 Email sales bjmp...

Отзывы: