  More  frequent  inspections  are  required  if  the  pump  is  used  in  a  harsh 

environment.  

  Preventative  maintenance  should  be  performed  to  reduce  the  chance  of 

premature failure.  

  Worn impellers and lip seals should be replaced. 

  Cut  or  cracked power  cords  must  be  replaced. 

(Never  operate  a pump with  a 

cut, cracked or damaged power cord.) 

  Seal oil should be checked once per year. 

  Maintenance  should  always  be  done  when  taking  a  pump  out  of  service  before 

storage.

 

 

1)  Clean pump of dirt and other build up. 
2)  Check condition of oil around the shaft seals. 
3)  Check hydraulic parts: check for wear. 
4)  Inspect power cable. Make sure that it is free of nicks or cuts.  

 
 

CHANGING SEAL OIL 

  

Changing the seal oil in the R series pumps is very easy. 
 

1)  Make sure that the pump cable is disconnected from the power source. 
2)  Lay the pump down on its side. 
3)  Remove the screws that hold the bottom plate in place.  
4)  Remove bottom plate. 
5)  Remove screws holding the suction cover. 
6)  Remove the suction cover. 
7)  Remove the impeller. 
8)  Remove the inspection screw for the oil chamber (pos#50-08). Pour 

out a small sample of the oil. If it is milky white, or contains water, then 
the oil and possible, the mechanical seal, should be changed. If an oil 
change is needed: 

9)  Remove the screws that hold the oil chamber cover in place & remove 

the oil. 

10) Replace the mechanical seal if necessary. 
11) Replace the oil. 
12) Assemble the pump. 

 

 

Содержание R08

Страница 1: ...THREE PHASE R100 R250 R400 R400D R400P R750 R1500 R1520 R1530 R08 R15 316 STAINLESS STEEL SINGLE PHASE THREE PHASE RX750SS RX1500SS RX08SS RX15SS Read this manual carefully before installing operating...

Страница 2: ......

Страница 3: ...T MAY NEED TO BE PRIMED 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF R100 16 EXPLODED VIEW OF R250 R400 R400D R400P 17 EXPLODED VIEW OF R750 RX7...

Страница 4: ...b site www bjmpumps com For assistance with your electric power source please contact a certified electrician Please pay attention to the following alert notifications They are used to notify operator...

Страница 5: ...attempt to alter the length or repair any power cable with a splice The pump motor and pump motor and cable must be completely waterproof Damage to the pump or personal injury may result from alterat...

Страница 6: ...mps distributor or BJM Pumps LLC If damaged the pump may need to be repaired before use Do not install or use the pump until appropriate action has been taken Lubrication No additional lubrication is...

Страница 7: ...e pump dry for extended periods of time Refer to data sheet for minimum submersion depth for your particular model Data sheets can be obtained online at www bjmpumps com or by calling BJM Pumps LLC at...

Страница 8: ...ld be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the...

Страница 9: ...anty considerations Always keep the plug end dry Note 230V single phase and 208V 230V 460V 575V three phase units do not have a plug and have to be provided separately Do not alter the length or repai...

Страница 10: ...or turn the power source off generator Typical 3 phase manual control 1 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE Maximum recommended starts should not exceed 10 times per hour AUTOMATIC OPERATI...

Страница 11: ...urce turn off the breaker or turn the power source off generator INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARREAR APP...

Страница 12: ...o not remove power supply cord and strain relief or connect conduit directly to the pump Installation and checking of electrical circuits and hardware should be performed by a qualified licensed elect...

Страница 13: ...g device also incorporate motor overload protection Pumps must be installed in accordance with the National Electrical Code and all applicable local codes and ordinances Pumps are not to be installed...

Страница 14: ...ck 4 Pumping air Check liquid level and position of pump 5 Excessive voltage drops due to long cables 6 Three phase only pump running backwards check rotation R400D ONLY NOTE THIS UNIT MAY NEED TO BE...

Страница 15: ...power cable Make sure that it is free of nicks or cuts CHANGING SEAL OIL Changing the seal oil in the R series pumps is very easy 1 Make sure that the pump cable is disconnected from the power source...

Страница 16: ...16 EXPLODED VIEW OF R100...

Страница 17: ...17 EXPLODED VIEW OF R250 R400 R400D R400P...

Страница 18: ...18 EXPLODED VIEW OF R750 RX750SS R1500 RX1500SS R1520 R1530...

Страница 19: ...19 EXPLODED VIEW OF R08 RX08SS R15 RX15SS...

Страница 20: ...258 202258 202258 202258 202258 13 Mechanical Seal Buna N 202269 202259 202259 202259 202259 200501 200501 200501 200501 200501 200501 13 Mechanical Seal FKM 202260 202260 202260 202260 200500 200500...

Страница 21: ...Screw for Strainer 202691 50 01 2 Screw for Bottom Plate 202689 202689 202689 203220 203220 203220 203220 203220 203220 50 01 3 Stud with Nuts R400D 202688 50 07 Screw for Suction Cover 203233 203239...

Страница 22: ...al Buna N Optional 200501 200501 200501 200501 14 Lower Ball Bearing 200958 200958 200958 200958 15 Impeller Shim Kit Required 200481 200481 200480 200480 16 Pump Casing Outer 202292 202294 202292 202...

Страница 23: ...202568 202568 202568 202568 50 01 2 Screw for Bottom Plate 203220 203220 203220 203220 50 07 Screw for Suction Cover 203250 203250 203250 203250 50 08 Screw for Oil Chamber Cover 203219 203219 203219...

Страница 24: ...24 SINGLE PHASE WIRING DIAGRAM 115V 230V W O GOVERNOR SWITCH MODELS R100 R250 R400 R400D R400P...

Страница 25: ...25 SINGLE PHASE WIRING DIAGRAM 115V 230V W GOVERNOR SWITCH MODELS R750 RX750SS R1500 RX1500SS R1520 R1530...

Страница 26: ...26 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 230V...

Страница 27: ...27 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 460V...

Страница 28: ...IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS EXPENSE DAMA...

Страница 29: ...29...

Страница 30: ...r Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counterclockwise Method used to check rotation viewed from bottom Resistance of ca...

Страница 31: ...top Yes No Control Panel MFG model no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit pr...

Страница 32: ...hecked for leaks Yes No Do check valves operate properly Yes No Flow Does station appear to operate at proper rate Yes No Noise level Acceptable Unacceptable Comments Describe and equipment difficulti...

Страница 33: ...NOTES...

Страница 34: ...k of BJM Pumps LLC Copyright 2006 2013 BJM Pumps LLC All rights reserved BJM Pumps LLC 123 Spencer Plain Road PO Box 1138 Old Saybrook CT 06475 USA Phone 860 399 5937 Fax 860 399 7784 Email sales bjmp...

Отзывы: