BJM Pumps FAHRENHEIT SK-F Series Скачать руководство пользователя страница 18

19 

SKX-F SERIES PARTS LIST 

Pump Model SKX750CSSF SKX1500CSSF

Pos. No.

Part Description

Part #

Part #

01-2

Stand Only

201988

201995

02

Suction Cover, Hi-Chrome

05

Impeller 

202951

204628**

07

Pump Housing 

202176

202172

07-1

O-Ring (Kit Only)

Kit

Kit

08

Oil Chamber Cover

202214

202214

08-1

O-Ring (Kit Only)

Kit

Kit

09

Lip Seal FKM

202232

202232

13

Mechanical Seal FKM

204240

204240

14

Lower Ball Bearing (*=qty 2 Needed)

200958

200958

14-2

Lower Bearing Retainer

202279

202279

15

Impeller Shim Kit (Required)

200481

200481

17

Rotor w/ Shaft 115/230V, 1PH

204061

204735

18

Stator w/ Casing 115V, 1PH (High-Temp)

201038

-

18

Stator w/ Casing 230V, 1PH (High-Temp)

201039

201041

19

Wire Connection Kit*

204211

204211

20

Upper Ball Bearing

200967

200967

21A

Oil Chamber/Motor Housing

202197

202197

21A-1

O-Ring (Kit Only)

Kit

Kit

21B

Motor Cover Upper

202368

202368

26

Pump Top Cover (w/ Sensor opening)

202434

202434

26-1

O-Ring (Kit Only)

Kit

Kit

27

Power Cable w/ Gland- 115V, 1PH (High-Temp)

202783

-

27

Power Cable w/ Gland- 230V, 1 PH (High-Temp)

202784

202783

27-1

O-Ring (Kit Only)

Kit

Kit

27-2

Seal Minder Cable (High-Temp)

201743

201743

27-2-1

O-Ring Kit Only

Kit

Kit

31D

Seal Minder Probe

202408

202408

31E

Ground Wire w/Ring Term.

203145

203145

32

Power Cord Line Clip / Strain Relief

203166

203166

33

Seal Minder Cable Line Clip

203163

203163

34

Handle / Chain Handle

202517

202517

35

Rod Bolts 

202682

202683

38

Discharge Nippple 2"

202532

-

38

Discharge Nipple 3"

-

202535

38E 

Discharge Elbow

202571

202559

38E-1

O-Ring, Discharge Elbow FKM

203326

203327

38F

Discharge Flange 2"

202563

-

38F

Discharge Flange 3"

-

202546

38F-1

Bolt - Suction Cover

202723

-

38F-1

O-Ring, 3" Discharge Flange FKM

-

202724

50-01-2

Bolt for Strainer/Stand

203228

203228

50-02

Bolt for Suction Cover

203228

203228

50-07

Screw for Oil Chamber/Motor Housing 

203296

203296

50-08

Screw for Oil Chamber Cover

203219

203219

50-11

Screw for Oil Fill 

203218

203218

50-11-1

O-Ring (Kit Only)

Kit

Kit

50-12

Screw for Pressure Check

203218

203218

50-12-1

O-Ring (Kit Only)

Kit

Kit

50-14-2

Screw for Bearing Retainer Plate

203219

203219

50-27

Screw for Power Cord

203295

203295

50-27-2

Screw for Seal Minder Cable

203295

203295

50-31E

Screw for Ground Wire

202692

202692

50-32/50-33

Screw for Line Clip

203214

203214

50-34

Screw for Handle

203219

203219

50-38E

Bolt for Discharge Elbow

203294

203271

50-38F

Bolt for Discharge Flange

203229

203294

202630

202630

O-Ring Kit - FKM

*"F" Series High Temperature Pumps Only

** New Rotor With Shaft Required When Upgrading From 202125 Impeller to 204628 Impeller.

Содержание FAHRENHEIT SK-F Series

Страница 1: ...e 208V 230V CAST IRON SINGLE PHASE SK1500C F 316 STAINLESS STEEL SINGLE PHASE SKX750CSS F SKX1500CSS F Read this manual carefully before installing operating or servicing these pump models Observe all...

Страница 2: ...HOOTING 13 PUMP WILL NOT RUN 13 PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF SK1500C F 16 EXPLODED...

Страница 3: ...tor or Industrial Flow Solutions Operating LLC Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399 5937 Fax 860 399 7784 Information including pump dat...

Страница 4: ...eated Do not operate the pump with a worn or damaged electric power cable Death or serious injury could occur Never attempt to alter the length or repair any power cable with a splice The pump motor a...

Страница 5: ...fully read all tags decals and markings on the pump 6 Important Always verify that the pump nameplate amps voltage phase and HP ratings match your control panel and power supply Warranty does not cove...

Страница 6: ...ures the oil is covering the motor windings by and that will be above the upper bearing Do not overfill an air gap of 10 15 must be maintained for heat expansion PUMP INSTALLATION SK F SKX F Series pu...

Страница 7: ...impeller Place on a solid surface or suspend the pump with a lifting rope chain The SK F SKX F Series pumps are provided with a suction strainer to prevent large solids from clogging the impeller Any...

Страница 8: ...ways to check the correct pump rotation 1 By looking at the impeller the rotation of the impeller should be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since...

Страница 9: ...ximum recommended starts should not exceed 10 times per hour All SK F SKX F Models are provided with a 50 15 m power cable NEVER splice the power cable due to safety and warranty considerations Always...

Страница 10: ...ontrol turn off the breaker and or turn the power source off generator CONTROL PANELS CONNECTION OPTIONS Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MA...

Страница 11: ...12 Figure 1 SKX750F 115 control Figure 2 SKX750F 230 SK1500 230 and SKX1500 230 control...

Страница 12: ...Pumps control is supplied as a manual ON OFF control A wide angle float can be wired in series with the thermal sensors to allow the pumps to operate in an automatic mode See the wiring diagram provi...

Страница 13: ...tory or by a factory trained and certified repair technician to insure that the materials and assembly methods meet BJM Pumps standards MAINTAINING YOUR PUMP Pump should be disconnected from the elect...

Страница 14: ...ins water then the oil and possible the mechanical seal should be changed If an oil change is needed 9 Remove the screws that hold the oil chamber cover in place remove the oil 10 Replace the mechanic...

Страница 15: ...16 EXPLODED VIEW OF SK1500C F...

Страница 16: ...17 EXPLODED VIEW OF SKX750CSS F SKX1500CSS F...

Страница 17: ...8 31E Ground Wire w Ring Term 203145 32 Power Cord Line Clip Strain Relief 203161 33 Seal Minder Cable Line Clip 203163 34 Handle Chain Handle 202517 35 Rod Bolts 202668 38 Discharge Nipple 3 202534 3...

Страница 18: ...08 202408 31E Ground Wire w Ring Term 203145 203145 32 Power Cord Line Clip Strain Relief 203166 203166 33 Seal Minder Cable Line Clip 203163 203163 34 Handle Chain Handle 202517 202517 35 Rod Bolts 2...

Страница 19: ...20 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS SK1500CF SKX750CSS F SKX1500CSS F...

Страница 20: ...winding and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings...

Страница 21: ...excluded IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS E...

Страница 22: ...s No Condition of Equipment New Good Fair Poor Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation viewed from bottom Use C W for clockwise CC W for counterclockwise R...

Страница 23: ...no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of sho...

Страница 24: ...ump on L1 L2 L3 FINAL CHECK Is pump secured properly Yes No Was pump checked for leaks Yes No Do check valves operate properly Yes No Flow Do pumps appear to operate at proper rate Yes No Noise level...

Страница 25: ...NOTES...

Страница 26: ...Operating LLC All rights reserved 2020 Industrial Flow Solutions Operating LLC All rights reserved Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399...

Страница 27: ...F SK37C F SK55C F SK75C F SK110C F SK150C F 316 STAINLESS STEEL THREE PHASE SKX08CSS F SKX15CSS F SKX22CSS F SKX37CSS F SKX55CSS F SKX75CSS F SKX110CSS F SKX150CSS F Read this manual carefully before...

Страница 28: ...K55C F SKX55CSS F SK75C F SKX75CSS F 22 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F 23 SK F SERIES PARTS LIST 24 SKX F SERIES PARTS LIST 26 THREE PHASE WIRING DIAGRAMS 28 208V 28 MODELS...

Страница 29: ...questions regarding the inspection disassembly and assembly or testing please contact your BJM Pumps distributor or Industrial Flow Solutions Operating LLC Industrial Flow Solutions Operating LLC 104...

Страница 30: ...disconnect the pump power cable to ensure that the pump will remain inoperative 3 Allow the pump to cool if overheated Do not operate the pump with a worn or damaged electric power cable Death or ser...

Страница 31: ...e model numbers and serial numbers from the pumps and control panel on the front of this instruction manual for future reference Give it to the owner or affix it to the control panel when finished wit...

Страница 32: ...any damage For Storage Periods longer than 3 Years Disassemble the pump and replace all of the O rings the Mechanical Seal Seal Chamber Oil and the Lip Seal Repack the Bearings Remove the air check s...

Страница 33: ...0 1 300 ISO 32 NSF Food Grade Mineral Oil SKX22CSS F 13 5 400 ISO 32 NSF Food Grade Mineral Oil SKX37CSS F 13 5 400 ISO 32 NSF Food Grade Mineral Oil SKX55CSS F 84 5 2500 ISO 32 NSF Food Grade Mineral...

Страница 34: ...g Industrial Flow Solutions Operating LLC at 860 399 5937 Do not run pump dry Pump liquid should not exceed a maximum temperature of 200 F 93 C Never place the pump on loose or soft ground The pump ma...

Страница 35: ...ld be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the...

Страница 36: ...SK F SKX F Models are provided with a 33 10 m power cord NEVER splice the power cable due to safety and warranty considerations Always keep the lead end dry Note 230V single phase and 208V 230V 460V...

Страница 37: ...tic mode unplug it from the power source turn off the breaker or turn the power source off generator Typical 3 phase manual control 1 TYPICAL AUTOMATIC WASTEWATERING INSTALLATION NOTE Maximum recommen...

Страница 38: ...r or turn the power source off generator INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARREAR APPROUV CONVENANT AU COURAN...

Страница 39: ...instructions provided with the panel to wire the system For automatic three phase pumps see automatic three phase wiring diagram Typical 3 Phase Auto Control 1 Before installing a pump make sure both...

Страница 40: ...l Equipment UL 50 or the standard for Metallic Outlet Boxes UL 514A and the standard for Motor Operated Water Pumps UL 778 TROUBLE SHOOTING Disconnect the power source to the pump BEFORE attempting an...

Страница 41: ...at regular intervals More frequent inspections are required if the pump is used in a harsh environment Preventative maintenance should be performed to reduce the chance of premature failure Worn impel...

Страница 42: ...10 Replace the mechanical seal if necessary 11 Replace the oil 12 Assemble the pump STATOR REPLACEMENT OR ELECTRICAL REPAIR The BJM Pumps F Series designed pumps utilize unique construction methods an...

Страница 43: ...18 EXPLODED VIEW OF SK08C F SK15C F...

Страница 44: ...19 EXPLODED VIEW OF SKX08CSS F SKX15CSS F...

Страница 45: ...20 EXPLODED VIEW OF SK22C F SK37C F...

Страница 46: ...21 EXPLODED VIEW OF SKX22CSS F SKX37CSS F...

Страница 47: ...22 EXPLODED VIEW OF SK55C F SKX55CSS F SK75C F SKX75CSS F...

Страница 48: ...23 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 49: ...0962 200962 14 2 Lower Bearing Retainer 202279 202279 202279 202279 203075 203075 203076 203076 14 3 Lock Nut Lock Washer 200424 200424 15 Impeller Shim Kit Required 200480 200480 200480 200480 200478...

Страница 50: ...36 203279 203279 50 07 Screw for Oil Chamber Motor Housing 203228 203228 203228 203228 203271 203271 203280 203280 50 08 Screw for Oil Chamber Cover 203219 203219 203219 203219 203246 203246 203281 20...

Страница 51: ...76 14 3 Lock Nut Lock Washer 200424 200424 15 Impeller Shim Kit Required 200480 200480 200480 200480 200478 200478 200478 200478 17 Rotor w Shaft 3PH 204021 204022 204023 204024 204027 204028 204029 2...

Страница 52: ...6 203279 20327 50 07 Screw for Oil Chamber Motor Housing 203296 203296 203296 203296 203271 203271 203280 20328 50 08 Screw for Oil Chamber Cover 203219 203219 203219 203219 203246 203246 203281 20328...

Страница 53: ...28 THREE PHASE WIRING DIAGRAMS 208V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F...

Страница 54: ...29 230V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F...

Страница 55: ...30 460V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 56: ...31 575V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 57: ...and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings These fo...

Страница 58: ...33...

Страница 59: ...excluded IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS E...

Страница 60: ...by hand Yes No Condition of Equipment New Good Fair Poor Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation viewed from bottom Use C W for clockwise CC W for counter...

Страница 61: ...no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of sho...

Страница 62: ...ump on L1 L2 L3 FINAL CHECK Is pump secured properly Yes No Was pump checked for leaks Yes No Do check valves operate properly Yes No Flow Do pumps appear to operate at proper rate Yes No Noise level...

Страница 63: ...NOTES...

Страница 64: ...Operating LLC All rights reserved 2020 Industrial Flow Solutions Operating LLC All rights reserved Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399...

Отзывы: