DO
read the installation instructions and study all diagrams. Begin the installation when you are
confident you understand the instructions completely.
DO
have another person help you with the installation. If you are not comfortable with the
mechanics of the installation, we suggest you hire the services of a licensed plumber, pump installer
or well driller.
DO
install the pipe and rod’s 8’ sections one at a time until the entire pipe and rod is installed.
DO
make sure one end of the safety rope is securely tied to the cylinder and the other end to a
secure object such as the well casing.
DO
turn the electricity off to the electric submersible pump before beginning the installation if you
are installing the hand pump in the same well as the electric submersible.
DO
use the paddle provided to aid in the installation of your pump.
DO
thread the ends of the rods together so they butt up against each other then tighten the lock nuts
with ½” & 9/16” open end wrenches.
DO
use Teflon tape on any male pipe threads which are not already taped before you screw them
together.
Note: Bison Pumps and any of its affiliates will not be held responsible for defects or damage to
this product due to inexperienced or negligent workmanship during installation of the pump and
associated parts.
INSTALLATION INSTRUCTIONS
(Bison Pumps recommend two people be involved for ease of installation.)
REQUIRED TOOLS: ½” and 9/16” open end wrenches, pliers, vice grips
STEP #1 -
Make sure you have read and understand the installation instructions.
STEP #2
- If you are installing the pump in a well casing specifically dedicated to a hand pump, go
to
STEP #6.
STEP #3
- If you are installing your Bison Deep Well Hand Pump
in the same casing as an electric
submersible pump or piping which connects to a jet pump, proceed as follows:
STEP #4
- Remove the existing well cover or well seal, whichever you may have and set it aside. *
If
you have a submersible pump, be sure to shut the electricity off to the pump before beginning the
installation of the Bison Hand Pump
*
If you are installing in the same casing as an electric submersible pump, in most
cases the electrical wires exit the top of the casing then run back down to the ground
with a piece of conduit. Using a bi-metal hole saw, drill a hole through the side of the
well casing 3-4” below the top of the casing then install the electrical conduit ell
(pictured – offered as an accessory by Bison Pumps).