DO 

read  the  installation  instructions  and  study  all  diagrams.  Begin  the  installation  when  you  are 

confident you understand the instructions completely. 

 

DO

  have  another  person  help  you  with  the  installation.  If  you  are  not  comfortable  with  the 

mechanics of the installation, we suggest you hire the services of a licensed plumber, pump installer 
or well driller. 

 

DO

 install the pipe and rod’s 8’ sections one at a time until the entire pipe and rod is installed. 

 

DO

  make  sure  one  end  of  the  safety  rope  is  securely  tied  to  the  cylinder  and  the  other  end  to  a 

secure object such as the well casing. 

 

DO

 turn the electricity off to the electric submersible pump before beginning the installation if you 

are installing the hand pump in the same well as the electric submersible. 

 

DO

 use the paddle provided to aid in the installation of your pump. 

 

DO

 thread the ends of the rods together so they butt up against each other then tighten the lock nuts 

with ½” & 9/16” open end wrenches. 

 

DO

 use Teflon tape on any male pipe threads which are not already taped before you screw them 

together. 

 

Note:  Bison Pumps and any of its affiliates will not be held responsible for defects or damage to 
this product due to inexperienced or negligent workmanship during installation of the pump and 
associated parts. 

 

INSTALLATION INSTRUCTIONS 
(Bison Pumps recommend two people be involved for ease of installation.) 
 

REQUIRED TOOLS: ½” and 9/16” open end wrenches, pliers, vice grips 

 
STEP #1 - 

Make sure you have read and understand the installation instructions. 

 

STEP #2 

- If you are installing the pump in a well casing specifically dedicated to a hand pump, go 

to 

STEP #6. 

 

STEP #3 

- If you are installing your Bison Deep Well Hand Pump

 

in the same casing as an electric 

submersible pump or piping which connects to a jet pump, proceed as follows: 
 

STEP #4 

- Remove the existing well cover or well seal, whichever you may have and set it aside. *

If 

you have a submersible pump, be sure to shut the electricity off to the pump before beginning the 
installation of the Bison Hand Pump

 

If  you  are  installing  in  the  same  casing  as  an  electric  submersible  pump,  in  most 
cases the electrical wires exit the top of the casing then run back down to the ground 
with a piece of conduit. Using a bi-metal hole saw, drill a hole through the side of the 
well  casing  3-4”  below  the  top  of  the  casing  then  install  the  electrical  conduit  ell 
(pictured – offered as an accessory by Bison Pumps). 

Содержание BPN-330C

Страница 1: ...ring a thunder and lightning storm Be aware of any overhead power lines DO NOT hurry the installation of your pump Think before you act DO NOT screw multiple lengths of pipe and rod together laid out...

Страница 2: ...affiliates will not be held responsible for defects or damage to this product due to inexperienced or negligent workmanship during installation of the pump and associated parts INSTALLATION INSTRUCTIO...

Страница 3: ...g temporarily The safety rope will be tied to the 1 4 eye bolt on the bottom of the well adaptor in step 13 See Detail A STEP 8 Note when you receive your rod one of the lock nuts will already be tigh...

Страница 4: ...rmed more easily with two people STEP 13 Tie the end of the safety rope to the 1 4 eye bolt on the underside of the well adaptor See Detail A Set the well adaptor and pump head onto the casing squarel...

Страница 5: ...ng codes in your area to be verify that your installation meets all code requirements 4 You will notice a handle locking loop is attached to your pump handle along with a stainless steel chain and hoo...

Страница 6: ......

Страница 7: ...3 8 x1 1 16 BP GN Gland Nut BPN 012 Bush Brz 3 8 x1 2 x3 4 Hdl BPN 069 Nut Ny locknut 316 3 8 16 BPN 018 scr Cup P Set 316 1 4 x1 4 BPN 121 Cup Seals Buna 3 Cyl Part Numbers Options DW Hand Pump BPN 3...

Страница 8: ...der performance equal to the 3 cylinder at the same levels 3 Cylinder up to a 100 static water level 1 The information in the chart is based on actual field tests and is intended as a general guide 2...