Bizon Pumps BPN-330C Скачать руководство пользователя страница 1

BISON DEEP WELL HAND PUMP  

INSTALLATION INSTRUCTIONS 

 

 
 
 
 
 
Inspect the contents of the box to be sure everything you ordered has been received. Be sure to check 
the  serial  number  on  the  pump  head  assembly  to  verify  it  matches  the  serial  number  on  your 
invoice/packing list.   
 

Read All Instructions Before Beginning the Actual Pump Installation 

 

DO'S & DON'TS FOR PUMP INSTALLATION 

 

 

DO  NOT

  begin  the  installation  without  first  reading  the  entire  instruction  booklet,  studying  and 

understanding the diagrams. 

 

DO 

NOT attempt the installation by yourself. 

 

DO NOT

 begin the installation of the pump without first checking the water level in your well to be 

sure you have enough pipe and rod to install the pump cylinder at least 20’ below the static water 
level. 

 

DO NOT

 over tighten the 1 ¼” pvc piping into the pvc female pipe thread bell end of the sch. 120 

plastic pipe. The pipe can be threaded with a pair of pliers or a 12” pipe wrench. 

 

DO NOT

 use large pipe wrenches for the assembly of the pvc piping. 

 

DO NOT

 install the pump during a thunder and lightning storm. Be aware of any overhead power 

lines. 

 

DO NOT

 hurry the installation of your pump. Think before you act. 

 

DO NOT

 screw multiple lengths of pipe and rod together, laid out on the ground, and then try to lift 

all the pipe and rod to a vertical position to lower it into the well. 

 

DO NOT

 lower the pump and pipe sections into the well by the safety rope.

 

 Grab the pipe securely 

with both hands and lower the pipe, cylinder and safety rope into the well 8’ at a time, using the 
paddle as a stop. The safety rope should be tied off to a secure object, i.e. the well casing so that it 
can be lowered slowly and safely. 

 
If you are going down more than 14 lengths of pipe and rod, mechanical means of 
lowering  them  into  the  well  is  recommended  along  with  the  Bison  lifting  tool  and 
adjustable rod. Gloves are recommended when handling rope.  

 
 
 
 

WARNING: All pumps are shipped with a stainless steel male pipe thread hose adaptor. You may 

want to check local codes to see if a hose Bibb backflow preventer should be used when 

connecting a hose to the hose adaptor on the pump. CONSULT YOUR LOCAL PLUMBING CODE!! 

BISON PUMPS 
PO BOX 977 
HOULTON, ME 04730 
[email protected] 
WWW.BISONPUMPS.COM 
1-800-339-2601

 

Содержание BPN-330C

Страница 1: ...ring a thunder and lightning storm Be aware of any overhead power lines DO NOT hurry the installation of your pump Think before you act DO NOT screw multiple lengths of pipe and rod together laid out...

Страница 2: ...affiliates will not be held responsible for defects or damage to this product due to inexperienced or negligent workmanship during installation of the pump and associated parts INSTALLATION INSTRUCTIO...

Страница 3: ...g temporarily The safety rope will be tied to the 1 4 eye bolt on the bottom of the well adaptor in step 13 See Detail A STEP 8 Note when you receive your rod one of the lock nuts will already be tigh...

Страница 4: ...rmed more easily with two people STEP 13 Tie the end of the safety rope to the 1 4 eye bolt on the underside of the well adaptor See Detail A Set the well adaptor and pump head onto the casing squarel...

Страница 5: ...ng codes in your area to be verify that your installation meets all code requirements 4 You will notice a handle locking loop is attached to your pump handle along with a stainless steel chain and hoo...

Страница 6: ......

Страница 7: ...3 8 x1 1 16 BP GN Gland Nut BPN 012 Bush Brz 3 8 x1 2 x3 4 Hdl BPN 069 Nut Ny locknut 316 3 8 16 BPN 018 scr Cup P Set 316 1 4 x1 4 BPN 121 Cup Seals Buna 3 Cyl Part Numbers Options DW Hand Pump BPN 3...

Страница 8: ...der performance equal to the 3 cylinder at the same levels 3 Cylinder up to a 100 static water level 1 The information in the chart is based on actual field tests and is intended as a general guide 2...

Отзывы: