SRP-330II/332II
Rev. 1.00
BIXOLON
- 125 -
BS SO S # RS m n
Function:
Transmit maintenance counter
Code:
ASCII
BS
SO
S
#
RS
m
n
Hex
08
0E
53
23
1E
m
n
Decimal
8
14
83
35
30
m
n
Range:
m = 1, n = 99, 102, 104
Default:
None
Description:
■
Transmits the value of the maintenance counter specified by n.
n
Maintenance counter (Units)
Hex
Deciamal
63
99
Number of autocutter operations.(Times)
68
104
Length of paper feed.(Km)
Remarks:
■
Maintenance counter data is consist of [Header ~ NULL] data as shown below:
Transmitted data
Hex
Deciaml
Amount of data
Header
5FH
95
1byte
Maintrnance counter
Depends on the mainternce counter(Units)
0
– 10byte
NUL
00H
0
1byte
■
The maintenance counter values are measurements; therefore, their values will be affected by the timing of errors
and how and when the power is turned off.
■
When this command is transmitted, do not transmit subsequent data until the status is received.
Differences: