Rev. 2.03
- 53 -
SMP6350
13. Frame Ground
It is advisable to connect the printer body and the platen roller block to the FG (frame
ground) of the outer case to prevent damage to the thermal head by static electricity.
Check performance by actually using the device.
Frame ground connection method
- Connect the frame ground terminal (FG: terminal No. 8, 9) of the FPC cable (50-pins) to
the frame ground (FG) of the outer case.
- Connect the frame ground (FG) of the outer case to the earth hole of the platen roller
block. Use the metal screws (screws and star washers coated with nickel) and the cable
of AWG18 or higher.
Fig 13-1 Frame ground dimensions
- Electric potential of all frame ground must be the same.
- Depending on the operating conditions, connect the GND terminal (SG) to FG, or put a
resistor of 1
MΩ between GND terminal (SG) and FG.