Bitstream HYPERION-402 Скачать руководство пользователя страница 4

                                                   

Quick start manual for 

H-402 

www.bitstream.pl/

 

 en/

   

1.4

Description of SFP optical ports

The optical ports are equipped with SFP slots and CU module with four dedicated SFP/SFP +

slots. The range and type of connector depends on the type of SFP insert. SFP slots support 100 and
1000 Mbit/s and SFP/SFP + slots support 1G/2.5G/10Gb.

Status signaling of 

 

 

SFP optical ports

 

 

External LED – signals transmission link for 1Gbps (if activity – blinking)

Internal LED – signals transmission link for 100Mbps (if activity – blinking)

Range and type of connector depends on the type of SFP insert.

2

P

OWER SUPPLY

Supply voltage range:          

version 7 – 36-60VDC power supply, for PoE in the range of 45-57VDC

version C – 80-360VDC or 75-270VAC power supply,

version 77p – 36-60VDC redundant power supply, for PoE in the range 45-57VDC

version CCp – 80-360VDC or 75-270VAC redundant power supply           

75-270VAC power supply does not support PoE function

Optional two supply inputs – redundant

Screw block connectors for DC or AC power supply

Total power consumption (without PoE ports) - <50W

Power supply also have power LED indicator (for each power supply)

Screw for GND connection

The power supplies in the device are protected against inverted power polarity. In case of 
reversing the polarity at the moment of connecting the power supply, the device will work.

3

POE POWER SUPPLY (A

DDITIONAL

 

OPTION

)

– 

Compliant with the IEEE802.3af standard, IEEE802.3at

– 

For 45-57V DC power, the power available for each port up to 30 or 90W. (depending on 

selected version)

 For 55VDC power, the maximum total PoE power is 500W

4

F

IRST START

-

UP

After connecting the power supply with appropriate parameters to the inputs, the PWR LED should

first light up, flashing alternately in two colours: orange and green, and then switch only to green. If
only one of the power supply inputs is used, only one PWR diode corresponding to this input will

light up. 

The red "ERR" LED's indicating the status of the modules and start blinking, which indicates that

the device is starting up. When the "ERR" LED's do not light up, the switch is ready for operation.

The device can be managed using the recommended Ethernet NMI or RJ45 interface via the RS-

232 console.

5

D

EFAULT PARAMETERS

IP parameters:

Address: 192.168.0.10

Mask: 255.255.255.0

User: admin                        Password: no password (empty)

SHORT USER MANUAL HYPERION-402

4/6

REV.

1.08

  2021.03.31

Отзывы: