Quick start manual for
H-402
1.3
Description of device connectors
RJ-45 connectors.
Fig 5.
The look and numbering of leads in RJ45 connector
The table shows the lay-out of particular signals for RJ-45 connectors
.
Status signaling of Ethernet interfaces
Each Ethernet port is equipped with two signaling diodes.
The left LED indicates link:
• LED 100M – orange – link 100Mbps (if activity – blinking)
• LED 1000M – green – link 1000Mbps (if activity – blinking)
The right LED indicates the power of PoE:
• LED orange – power indicator flashing for special mode "manual" (Permanently powered port with the PoE
detection turned off)
• LED green – delivered power in PoE+ or PoE++
Distribution of signals for the serial port connectors shown in the following table:
RJ-45
connector
PORT RS232
DSUB-9
(female)
5
GND
5
7
TX – RX
2
8
RX – TX
3
SHORT USER MANUAL HYPERION-402
3/6
REV.
1.08
2021.03.31
RJ-45 Ethernet 10/100Mbit/s CONNECTOR
1 (white and orange)
RXAn
Receiver of channel
2 (orange)
RXBn
3 (white and green)
TXAn
Transmitter of channel
6 (green)
TXBn
RJ-45 Ethernet 1000Mbit/s CONNNECTOR
1 (white and orange)
BI_DA+
Bi-direcA contact
2 (orange)
BI_DA-
Bi-directional -A contact
3 (white and green)
BI_DB+
Bi-direcB contact
4 (blue)
BI_DC+
Bi-direcC contact
5 (white and blue)
BI_DC-
Bi-directional -C contact
6 (green)
BI_DB-
Bi-directional -B contact
7 (white and brown)
BI_DD+
Bi-direcD contact
8 (brown)
BI_DD-
Bi-directional -D contact